Home
>
Aluratek
>
Audio-visual interconnect box
>
Aluratek TCPIP TO RS232 ADAPTER AC301201 User Guide
Aluratek TCPIP TO RS232 ADAPTER AC301201 User Guide
Have a look at the manual Aluratek TCPIP TO RS232 ADAPTER AC301201 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 43 Aluratek manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
![](/img/blank.gif)
AC301 AC301 AC301 AC301- -- -201 201201 201 TCP/IP to RS TCP/IP to RSTCP/IP to RS TCP/IP to RS- -- -232 Adapter 232 Adapter232 Adapter 232 Adapter User’s Guide 400-0446-002 1 Welcome! We greatly appreciate your purchase of the AC301-201 TCP/IP to RS-232 Adapter. We are sure you will find it reliable and si mple to use. Superior performance for the right price, backed by solid tec hnical and customer support is what ALTINEX has to offer. We are committed to providing our customers with Signal Management Solutions ® to the most demanding audiovisual installations at very competitive pricing and we welc ome you to join the ranks of our many satisfied customers throughout the wo rld. 1. Precautions and Safety Warnings Please read this manual carefully before using your AC301-201. Keep this manual handy for future reference. These safety instru ctions are to ensure the long life of your AC301-201 and to prevent fire and shock hazards. Please read them carefully and heed all warnings. 1.1 General · Qualified ALTINEX service personnel or their authoriz ed representatives must perform all service. 1.2 Installation Precautions · To prevent fire or shock, do not expose this unit to w ater or moisture. Do not place the AC301-201 in direct sunlight, near heaters or heat-radiating appliances, or near any liquid. Exposu re to direct sunlight, smoke, or steam can harm internal components . · Handle the AC301-201 carefully. Dropping or jarring can cause damage. · Do not pull the cables that are attached to the AC30 1-201. 1.3 Cleaning · Clean only with a dry cloth. Never use strong deterge nts or solvents, such as alcohol or thinner. Do not use a wet cloth or water to clean the unit. Do not open the unit to clean. 1.4 FCC Notice · This device complies with Part 15 of the FCC Rules. O peration is subject to the following two conditions: (1) This devi ce may not cause harmful interference, and (2) this device must accep t any interference received, including interference that may cause unde sired operation. · This equipment has been tested and found to comply wit h the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection a gainst harmful interference when the equipment is operated in a co mmercial environment. This equipment generates, uses, and can ra diate radio frequency energy and, if not installed and used in ac cordance with the instructions found herein, may cause harmful interfe rence to radio communications. Operation of this equipment in a re sidential area is likely to cause harmful interference in which case t he user will be required to correct the interference at his own expe nse. · Any changes or modifications to the unit not expressly approved by ALTINEX, Inc. could void the user’s authority to op erate the equipment. 2. Installation Procedures Step 1. Connect the AC301-201 directly to the 9-pin D-sub connector of the MultiTasker enclosure or other RS-232 serial controlled device. If connecting through a cable and not directly to the MultiTasker, make sure the cable has a conductor for pin 9 or use the external adapter. Step 2. If controlling a device other than a MultiT asker enclosure, it is necessary to connect the external power adapter to the DC power jack located on the side of the AC301-201. The LED should be on and red w hen power is present. The LED inside the AC301-201 is l ocated near the RJ-45 connector and is visible through the seam in the enclosure. Step 3. Connect the RJ-45 connector on the opposite end of the AC301-201 to the LAN using a standard UTP ( CAT-5) type cable. Step 4. The AC301-201 is now operational. The defaul t IP is assigned by the LAN and uses port number 10001 for the TCP/IP connection. Note: The IP can be preset by ALTINEX at the time o f purchase. For best results, have a fixed IP assigned by your IT department and then set by ALTINEX prior to shipping. See Section 7.1 of the o nline manual for changing the configuration using th e DeviceInstaller application or use the TELNET option below. Step 5. Change the IP address or baud rate using TELNE T from a command prompt. The TELNET port is 9999. A. At the command prompt enter TELNET, the curren t IP, and port 9999. Example: C:\> TELNET 192.168.1.155 9999 B. Press Enter when prompted to enter the setup mode . C. Select the option to change, and at each prompt enter the new value or just press Enter to leave unchanged. Option 0 Server................................ Ch ange IP, mask, and gateway. (set IP 0.0.0.0 for DHCP) Option 1 Channel 1 ......................... Change baud rate Option 8 Exit without save.............. Cancel ch anges and exit setup mode Option 9 Save and Exit .................... Save ch anges and exit The changes may take a few seconds to be recognized b y the network. 3. Limited Warranty/Return policies Please see the ALTINEX website at www.altinex.com for details on warranty and return policies.
![](/img/blank.gif)
AC301 AC301 AC301 AC301- -- -201 201201 201 User’s Guide 400-0446-002 2 4. Technical Specifications Specifications are subject to change. See www.altinex.com for up-to-date information. Features/Description AC301-201 Input/Output Ethernet/LAN RJ-45 F (1) Serial 9-pin D-sub M (1) Compatibility Baud Rates 1200 through 115,200 Table 1. AC301-201 General Mechanical AC301-201 Material 0.06 Plastic Color Black Height (inches) 0.92 in (23.4 mm) Width (inches) 1.68 in (42.7 mm) Depth (inches) 3.35 in (85.1 mm) Weight (pounds) 0.40lb (0.18kg) T° Operating 10 °C-35 °C T ° Maximum 50 °C Humidity 90% non-condensing MTBF (calculations) 40,000 hrs Table 2. AC301-201 Mechanical Electrical AC301-201 Input/Output Signal Serial (9-pin D-Sub) RS-232 Standard Ethernet/LAN TCP/IP 10/100 Mbps Default Settings IP (automatic allocation) DHCP Subnet mask 255.255.255.0 Gateway 0.0.0.0 Port 10001 RS-232 9600 Baud Power External Adapter 9VDC@500mA MultiTasker 6VDC from MultiTasker Table 3. AC301-201 Electrical * The AC301-201 receives power from the MultiTasker e nclosure. If the AC301-201 is used to communicate with a different de vice, it must be powered using an external adapter. ** The MultiTasker enclosure provides power to the AC3 01-201 through the 9-pin connector. If using a cable between the AC 301-201 and the MultiTasker, make sure that pin 9 has a conductor pres ent.
![](/img/blank.gif)
AC301 AC301 AC301 AC301- -- -201 201201 201 User’s Guide 400-0446-002 3 5. About Your AC301-201 The AC301-201 provides a method for communicating with a MultiTasker system, or other RS-232 serial device, over an existing local area network (LAN). The IP address (Internet Protocol address) may be set autom atically or assigned manually during the initial installation. The AC301-201 is compact and easy to use. It offers a male 9-pin D-Sub RS-232 serial input connection and a female RJ-45 network connection. Additional features include an adjustable baud rate and built-in ESD protection. ETHERNET IP CONNECTOR 9-PIN D-Sub RS-232 AC301-201 DC POWER JACK POWER LED
![](/img/blank.gif)
AC301 AC301 AC301 AC301- -- -201 201201 201 User’s Guide 400-0446-002 4 6. Application Diagrams Diagram 1: Typical Setup AC301-201 INTERNET MU LT I T A S K E R
![](/img/blank.gif)
AC301 AC301 AC301 AC301- -- -201 201201 201 User’s Guide 400-0446-002 5 Diagram 2: Internal View DC+6V RX DATA IN DATA OUT AC301-201 TX POWER ETHERNET TTLTX 9-PIN D-Sub ETHERNET RJ-45 POWER JACK TRANCEIVER to RS-232
![](/img/blank.gif)
AC301 AC301 AC301 AC301- -- -201 201201 201 User’s Guide 400-0446-002 6 7. Operation The AC301-201 requires no adjustments for operation. Once connected, the AC301-201 will work trouble free without user in tervention. 7.1 TCP/IP Setup Note: This section uses the DeviceInstaller application to change the AC301-201 configuration or the device. DeviceInstaller 1. Download the DeviceInstaller for the XPort devi ce from the ALTINEX website, www.altinex.com. The DeviceInstaller is a software utility for the E thernet to serial controller. This software requires Windows .NET Framewo rk to be installed on the computer. 2. Run setup.exe from the downloaded files to insta ll the application. 3. Connect the AC301-201 to the LAN using standard CA T-5 cable. 4. The device must have power on in order to proceed . Make sure the power LED is on and red. 5. Launch the installer from the Start menu or from the directory noted earlier. This will allow the configuration of the X Port device. 6. Click on the Search button to check for new de vices on the LAN. This will take a few seconds. The IP Address 7. Once the device is located, click on the device i n the installer window and make note of the IP address. Note: If you want to assign the IP manually, click A ssign IP. This method may require the assistance of your IT Administra tor. Configure the Device 8. The device may be configured using a web browser or using a Telnet session. This procedure uses the Telnet option. Click th e Telnet button and do not change the default port number of 9999. Click OK to proceed. 9. When the command window appears, press Enter when p rompted to enter Setup Mode. 10. At the Change Setup prompt, select Factory De faults. 11. Next, select Channel 1 Configuration. 12. View each line item as it appears. Press Enter to l eave the default value, or enter the new value and press Enter. NOTE: The Port No. in the configuration menu is t he COM port used for RS-232 communication. 13. Select Save and Exit to keep the changes and exit setup mode. 14. Close the DeviceInstaller; setup is complete. Use the port number assigned above to communicate over the LAN. 15. Launch AVSnap or other communication software in order to communicate with the MultiTasker. 16. Setup the TCP/IP connection using the Host and Po rt numbers assigned during the above installation.
![](/img/blank.gif)
AC301 AC301 AC301 AC301- -- -201 201201 201 User’s Guide 400-0446-002 7 7.2 Connection Examples Following are connection examples using AVSnap and HyperTerminal: Example - AVSnap: 1. Launch AVSnap and enter Communication Mode. 2. Right click in the terminal window and select Pa ge Setup. 3. Under the COM Setup, select the TCP option. Enter the IP address for the Host and port number (10001 is the default fr om above) for the Port. The IP address 192.168.1.100 is only an example. Your IP address will vary depending on your network settings. Example - HyperTerminal: 1. Launch HyperTerminal and start a new connection. This example uses the connection name AC301-201 and HyperTermina l version 5.1 running under Windows XP. 2. Select Connect Using: TCP/IP and then enter the IP address and port number.
![](/img/blank.gif)
AC301 AC301 AC301 AC301- -- -201 201201 201 User’s Guide 400-0446-002 8 8. Troubleshooting Guide We have carefully tested and found no problems in the supplied AC301-201. However, we would like to offer suggestion s for the following: 8.1 LED is Not Red There is a power LED next to the RJ-45 connector on the AC301-201. The LED is visible through the seam of the plastic enclosu re. Cause 1: There is no power. Solution: Verify the AC301-201 is connected directly to the MultiTasker and that the MultiTasker enclosure has power and is tur ned on. If LED is still not on, see Cause 2. Cause 2: The wrong cable is being used. Solution: If there is a cable between the AC301-201 and the MultiTasker, verify pin 9 of the cable has continuit y throughout the cable. If the LED is still not on, see Cause 3. Cause 3: The AC301-201 is not connected to a MultiTask er. Solution: If the AC301-201 is not connected to a MultiTasker, then the external power adapter must be connected. Connect th e power adapter to the AC301-201. If the LED is still not on, see Cause 4. Cause 4: The AC301-201 has a problem. Solution: If there is still no power, the AC301-201 may requi re service. Please, call ALTINEX at (714) 990-2300. 8.2 No Communication Cause 1: The devices are incompatible. Solution: Connect the computer directly to the destination de vice using a standard RS-232 cable. If the devices communicate w ithout the AC301-201, the problem is with the cables or AC30 1-201; see Cause 2. Cause 2: Cable connections are wrong. Solution 1: Verify the output of the AC301-201 is connected to the input of the serial device. Solution 2: Verify that the Signal Present LED on the AC301-20 1 is on and red. If the LED is on and red, check the connection between the computer and the AC301-201. Solution 3: If the LED on the AC301-201 is red, use the DeviceIn staller as described in the installation section. If the AC301-20 1 is seen on the network and the LED is on and red, and there is still no communication, call ALTINEX at (714) 990-2300.