    Thank you for purchasing the MINI-ME™ RT300-145 RJ-45 
    retractable cable. W e know you will find it easy to install, easy to 
    use and easy to maintain.  
    Our goal is to provide our customers with unique Signal 
    Management Solutions® for Audio Visual applications.  
    1. Precautions and Safety Warnings 
    Please read this manual carefully before using MINI-ME RT300-
    145 RJ-45 Cable Retractor. Keep this manual handy for future 
    reference. These safety instructions are to ensure the long life of 
    your cable retractor and to prevent fire and shock hazards.  
    1.1 General 
     The RT300-145 does not contain any user serviceable 
    parts inside. 
     Do not disassemble the unit. RT300-145 contains high-
    tension spring that can uncoil rapidly causing cutting 
    hazard. 
     Only qualified Altinex service personnel is allowed to 
    perform cable retractor repairs. Removal of the warranty 
    sticker will void the warranty. 
    1.2 Installation 
     Use the RT300-145 RJ-45 cable retractor in a dry area 
    away from dust and moisture. 
     Do not place the RT300-145 RJ-45 cable retractor in direct 
    sunlight, near heaters or heat-radiating appliances, or near 
    any liquid. Exposure to direct sunlight, heat, and moisture 
    will damage internal precision components. 
     Handle the RT300-145 RJ-45 cable retractor with care. 
    Dropping, straining, or shaking can damage internal 
    components. 
     Do not place heavy objects on top of the RT300-145 RJ-45 
    cable retractor. 
     Follow installation instructions RT300-145 for optimum 
    performance. 
    1.3 Cleaning 
     Clean surfaces with a dry or slightly damp cloth. Do not use 
    detergents or solvents. 
    2. Installation Procedures 
     
    Step 1 Mount the RT300-145 onto the AC200-125 or AC221-125 
    mounting bracket and secure it with the four 4x40 screws 
    provided.  
    Step 2 Slide mounting bracket onto the CNK200 or CNK221 exterior hooks 
    and secure the thumbscrews with the wing nuts provided by the 
    accessories. 
    Step 3 Feed retractable cable through the bottom of the CNK unit and the 
    faceplate.  
    Step 4 Connect the fixed cable to a display or a switcher 
    Step 5 Refer to CNK200 or CNK221 user guide for installation instructions. 
     
     
    3. Limited Warranty/Return Policies 
     
    Please visit Altinex website at www.altinex.com for details on warranty and 
    return policies. If you have any questions, please call us at 1-800-ALTINEX or 
    714-990-2300. 
     
       
    						
    							RT300-145 User’s Guide 
    400-0591-001 
     
     
     
     
     
    2 
     
    4. Technical Specification 
    Specifications are subject to change. Please visit www.altinex.com for up-to-date specification 
     
     
    Features/Description  
    Inputs  
    Network RJ-45 format 
    Outputs  
    Network RJ-45 format 
    Compatibility  
    Tabletop enclosures CNK200 & CNK221 
    Stand-alone mounting Mounting holes with 
    4x40 threads are 
    provided 
    Additional Accessories  
    Mounting Hardware AC200-125 for 
    CNK200 
    AC221-125 for 
    CNK221 
     
    Table 1 RT300-145 General Specifications 
     
    Mechanical  
    Dimensions  
    Height 4.8 in (122 mm) 
    Width 4.8 in (122 mm) 
    Depth 1.4 in (37 mm) 
    Other  
    Normal Pull force 0.3lb (+/- 0.1) 
    End of the cable pull 
    force 
    Max 10lb (+2lb) 
    (Damage may occur if 
    customer forces retract past 
    the end of cable) 
    Weight  0.78 lbs. (0.353 kg) 
    Color Black 
    Material Plastic 
    T Operating 10C - 35C 
    T Maximum 50C 
    Humidity 90 non-condensing 
    MTBF (tested) 10,000 retractions 
     
    Table 2 RT300-145 Mechanical Specifications 
     
    Electrical RT300-145 RJ-45 
    Retractable Cable 
    Cable Gauge 36AWG wires, 
    32AWG coaxes 
    Voltage Rating for Cable 30V 
    Power none 
    Amplifier none 
    Table 3 RT300-145 Electrical Specifications 
     
     
       
    						
    							RT300-145 User’s Guide 
    400-0591-001 
     
     
     
     
     
    3 
     
    5. The MINI-ME RT300-145 RJ-45 Retractable Cable features 
     Convenient, easy to install cable retraction system for 
    CNK200, CNK221 interconnect box and stand alone 
     Simple operation for AV connectivity 
     RJ-45 compliant coaxial cable 
     CNK200 supports four MINI-ME RT300-145 units 
     CNK221 supports two MINI-ME RT300-145 units  
     Tested to 10,000 retracts 
     
     
     
     
     
     
     
     
    The RT300-145 offers a solution for managing RJ-45 cables. The cable assembly was designed to provide optimum 
    performance . The RT300-145 has 4.0 ft of retractable cable and 4 ft of the fixed length cable. The cable and the retractor 
    has been tested to over 10,000 extensions/retractions. The AC200-125 and AC221-125 mounting hardware securely 
    mounts the cable retractors to CNK200 and CNK221 table top units. 
     
     
     
     
    AC200-125 mounting bracket for the CNK200 
     AC221-125 mounting bracket for the CNK221 
     
     
       
    						
    							RT300-145 User’s Guide 
    400-0591-001 
     
     
     
     
     
    4 
     
    6. Application Diagram 
     
    Diagram 1: Typical RT300-145 Installation and use 
     
     
     
    Diagram 2: Retractor Side Dimensions 
      
    						
    							RT300-145 User’s Guide 
    400-0591-001 
     
     
     
     
     
    5 
     
     
    Diagram 3: Front Dimensions 
     
     
    Diagram 4: Mounted on a CNK200 Front View 
     
     
    Diagram 5: Mounted on a CNK200 Side View 
     
     
      
    						
    							RT300-145 User’s Guide 
    400-0591-001 
     
     
     
     
     
    6 
     
     
      
     
    Diagram 6: Mounted on a CNK221 Front View 
     
     
     
    Diagram 7: Mounted on a CNK221 Side view 
     
    7. Operation 
     
    7.1 Accessing the RT300-145 RJ-45 Retractable 
    Cable 
    After  proper  installation,  no  further  configuration  is 
    needed.  To  connect,  simply  open  the  CNK  bezel  and 
    pull  on  the  cable.  Connect  to  desired  source.  When 
    finished,  disconnect  the  source  and  automatically  the 
    cable will retract back into the bezel. 
      
    						
    							RT300-145 User’s Guide 
    400-0602-001  
     
     
     
     
     
     
    7 
     
    8. Troubleshooting Guide 
    The RT300-145 RJ-45 Retractable  Cable  supplied  was 
    carefully  tested  and  no  problems  were  detected. 
    However,  we  would  like  to  offer  the  following 
    suggestions: 
    Please make sure that the highest quality cables are 
    used in addition to the retractable cable.  
    Make sure that no cable or power cord is damaged or 
    pinched. If there has been damage, do not use the 
    CNK200 or the retractable cable. Please call the Altinex 
    Customer Service Department at (714) 990-2300 to 
    have the unit repaired. 
     
      
    						