    Have a look at the manual Aluratek POWERCURRENT SENSOR AND INTEGRATED CONTROLLER AC301102 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 43 Aluratek manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							AC301-102 & AC301-106 Power Sensors User’s Guide 
    400-0536-001   
     
     
     
     
     
     
    1 
     
     
    Welcome! 
    We greatly appreciate your purchase of the  AC301 -102/106  Power 
    Sensor/Controller . We are sure you will find it reliable and simple to use. 
    Superior performance for the right price, backed by solid technical and 
    customer support is what ALTINEX ha s to offer. 
    We are committed to providing our customers with Signal  Management 
    Solutions
    ®  to the most demanding audiovisual installations at competitive 
    pricing and we welcome you to join the ranks of our many satisfied 
    customers throughout the world.  
    1. P recautions and Safety Warnings 
    Please read this manual carefully before using your AC301 -102/106 Power 
    Sensor/Controller  and keep it handy for future reference. These safety 
    instructions are to ensure the long life of your  AC301-102/106  and to prevent 
    fire  and shock hazards. Please read them carefully and heed all warnings.  
    1.1 General  
    •   There are no user serviceable parts inside. Qualified ALTINEX service 
    personnel must perform all service on the  AC301-102/106 . 
    1.2 Handling  
    •   For best results, place the  AC301-102/106  on a flat, leveled surface in a 
    dry area away from dust and moisture.  
    •   To prevent fire or shock, do not expose this unit to water or moisture. 
    Do not place the  AC301-102/106  in direct sunlight, near heaters, or 
    heat -radiating appliances, or near any  liquid. Exposure to direct 
    sunlight, smoke, or steam can harm internal components.  
    •   Handle the unit  carefully. Dropping or jarring can cause  damage. 
    •   Do not pull any cables that are attached to the AC301 -102/106 . 
    •   Do not place heavy objects on top of the  AC3 01-102/106 .  1.3 Cleaning
     
    •   Unplug the AC301 -102/1063  before cleaning.  
    •   Clean only with a dry cloth. Never use strong detergents or solvents 
    such as alcohol or thinner. Do not use a wet cloth or water to clean the 
    unit. Do not open the unit to clean.  
    1.4 FCC Notice  
    •   This device complies with Part 15 of the FCC Rules. Operation is 
    subject to the following two conditions: (1) This device may not cause 
    harmful interference, and (2) this device must accept any interference 
    received, including interference that may c ause undesired operation. 
    •   This equipment has been tested and found to comply with the limits for 
    a Class A digital device, pursuant to Part 15 of the FCC Rules. These 
    limits are designed to provide reasonable protection against harmful 
    interference when th e equipment is operated in a commercial 
    environment. This equipment generates, uses, and can radiate radio 
    frequency energy and if not installed and used in accordance with 
    instructions found herein, may cause harmful interference to radio 
    communications.  Operation of this equipment in a residential area is 
    likely to cause harmful interference in which case the user will be 
    required to correct the interference at his own expense.  
    •   Any changes or modifications to the unit not expressly approved by 
    ALTINEX, In c. could void the user’s authority to operate the 
    equipment.  
     
     
    2. Installation Procedures  
    Special Considerations:
    •  The  AC301 -102/106  should be located as close as feasible to the AC outlet  and t he AC 
    outlet should be easily accessible.  
       
    •   The  AC301 -102/1 06 must lay flat to minimize mechanical stress on the AC cord.  
    •   The total AC cord length from the outlet to the monitor (including the  AC301-102/106 ) 
    must be at least 1.5  m  (4.92 ft) and less than 4.5  m  (14.76  ft).  
    Step 1.  Make a cable to connect the Neutro n Controller to the AC301-102/106  using the terminal block 
    connectors provided with each unit . Use 24 AWG multi-conductor cable for best results  and make 
    sure the cable is long enough to route neatly between the AC301 -102/106 and the Neutron . The 
    following  are  the  minimum  connection  requirements  (see the wiring diagram above) : 
    AC301  :   .............  12 Volts ............  Relay Control  ...........  Signal Ground  
    Neutron  :   ...........  12 V ..................  Relay Pole .................  Relay Throw  &  Gnd  
    Note:  The AC301's sensor output pin can be connected to a sensor input on the Neutron in 
    ord er to monitor the load on the output of the AC301.  
    Step 2.  Insert the AC301 -102/106 between the AC outlet and  external device as shown to the right.  
    Step  3.  Connect the  AC301-102/106  control input to the Neutron Controller using the cable from Step 1.  
    Step  4 .  Lay the  AC301-102/106  flat on its operating surface ; it must NOT  hang from either of the AC cables.  
    Step  5 .  The  AC301 -102/106 Power Sensor/Controller  is now operational.  The AC Output indicator LED next 
    to the output AC cord is  ON when  the AC output is  on . The AC output is ON when there is  +12V 
    applied  and the Relay Control input  is connected to GND. 
    3. Limited Warranty/Return  Policies 
    Please see the ALTINEX website at 
    www.altinex.com  for details on warranty and re turn policies. 
     
      
    						
    							AC301-102 & AC301-106 User’s Guide 
    400-0536-001   
     
     
     
     
     
    2 
     
    4. Technical Specifications 
    Specifications are subject to change.  See 
    www.altinex.com  for up -to -date information.  
     
    Features/Description   AC301-102/106  
    Inputs   
      AC (pass-through) AC301- 102  NEMA 5-15P  (1) 
      AC (pass -through) AC301- 106  IEC M – C14 (1)  
      Control/Power   4-pin Terminal Block (1)  
    Output   
      AC (pass-through) AC301- 102  NEMA 5-15R (1)  
      AC (pass-through) AC301- 106  IEC F – C13 (1)  
    Compatibility    
      AC Devices  Audiovisual Devices
     
    (monitors,  projectors,  etc.)  
    Accessories Included    
      Control Input Mating Connector  4-pin Terminal Block (1)  
    Table 1. AC301-102/106 General 
      Mechanical
      AC301-102/106  
    Material  Steel 
    Color   Black 
    Height  0.9 in  (23  mm)  
    Width  6.0 in (152  mm) 
    Depth  2.6 in  (66  mm)  
    Weight   0.5 lb  (0.2  kg)  
    T° Operating   10°C-35° C 
    T° Maximum   50°C 
    Humidity  
    90% non- condensing  
    MTBF (calculations)   40,000 hrs (min.) 
    Table 2. AC301-102/106 Mechanical  
    Electrical   AC301-102/106  
    AC Pass -Through   
      AC minimum   120/240 V 50/60 Hz
     
    5 0 m A 
      AC m aximum   120/240 V 50/60 Hz
     
    5 A  
    Power Consumption   (from controller) 
       +12V    40 mA (0.5  W)  
    Table 3. AC301- 102/106 Electrical  
     
      
    						
    							AC301-102 & AC301-106 User’s Guide 
    400-0536-001   
     
     
     
     
     
    3 
     
    5. About Your AC301-102/106 
    •   Large Load Capacity, 50 mA to  5 A AC at 120 or 240 VAC  
    •   Remote on/off of  live  AC  line 
    •   Current s ensor output  voltage  
    •   Live line circuit breaker  
    The  AC301 -102/106  Power Sensor/Controller  allows the  ALTINEX Neutron controllers to  remotely control the AC power applied to a single audiovisual device 
    as well as monitor the power consumption of  the device .  The AC301 -102 has a NEMA male connector on the supply side with a NEMA female connector on the 
    output; the AC301 -106 has an IEC male connector on the supply side and an IEC female connector on the output.  
    The earth and neutral lines are straight pass -throu gh lines, always connected to the AC output for the  external device. The Power Sensor/Controller turns on and 
    off power by switching the live line through an internal relay.  
    The AC301 -102/106 sensor outputs approximately 2V per amp of AC load with a maximu m of 10V at 5A. The sensor inputs on the Neutron Controllers can be 
    used to monitor the sensor output voltage level of the AC301 -102/106.  The sensor voltage relates directly to the load on the output of the AC301 -102/106  and can 
    be used to determine the ap proximate load or simply an on or off condition of the AC device.   
    In addition to sturdy construction and safety rated components, a dditional safety is provided in the form of a built-in circuit breaker. The circuit breaker is a 
    push- to-reset model designed to protect the branch circuit from overload conditions.  
     
     
    AC301 -102   AC301-106  
     
     
     
     
      
     AC301-102 - NEMA AC301-106 - IEC 
    CIRCUIT
    INPUTPOWER/CONTROL
    AC OUT
    AC OUTPUT
    INPUT
    POWER/CONTROL
    AC INPUT OUT TO MONITOR
    CIRCUIT BREAKER
    BREAKER
    POWER/CONTROL
    INPUT
    BREAKER CIRCUIT
    AC INPUT
    AC OUT
    AC INPUT
    INDICATOR LED AC OUTPUTINDICATOR LED AC OUTPUT
    IEC
    NEMA
    NEMA IEC
    INDICATOR
    AC INPUT
    INPUT
    POWER/CONTROL
    CIRCUIT BREAKER
    OUT TO MONITOR
    AC OUTPUTINDICATOR
      
    						
    							AC301-102 & AC301-106 User’s Guide 
    400-0536-001   
     
     
     
     
     
    4 
     
    6. Application Diagrams 
    Diagram  1 :  Typical Setup  
     
     
      
    						
    							AC301-102 & AC301-106 User’s Guide 
    400-0536-001   
     
     
     
     
     
    5 
     
    Diagram 2 :  Internal View AC301 -102 
     
     
    CURRENT DETECT
    POWER
    I SENSE
    ON/OFF
    POWER
    NEMA 5-15P
    TERM BLOCK
    +12V
    LIVE
    OUTPUT
    INPUT/CONTROL
    NEUTRAL GROUND
    GROUND
    NEUTRAL LIVE
    LIVE
    NEMA 5-15R
      
    						
    							AC301-102 & AC301-106 User’s Guide 
    400-0536-001   
     
     
     
     
     
    6 
     
    Diagram 3 :  Internal View AC301 -106 
     
     
    CURRENT DETECT
    POWER
    I SENSE
    ON/OFF
    POWER
    IEC M
    TERM BLOCK
    +12V
    LIVE
    OUTPUT
    INPUT/CONTROL
    NEUTRAL GROUND
    GROUND
    NEUTRAL LIVE
    LIVE
    IEC F
      
    						
    							AC301-102 & AC301-106 User’s Guide 
    400-0536-001   
     
     
     
     
     
    7 
     
    7. Operation 
    The  AC301 -102/106  requires no adjustments for optimum  performance. 
    Once set -up, the AC301 -102/106  will work trouble -free without user 
    intervention.   
    R emember: the AC device should draw at least 50 mA of AC c urrent and 
    not more than 5A AC.  
    7.1 Device Control  
    The  AC301 -102/106  automatically enables power to the device  wh ile 
    the  Relay Control  input line is connected to ground . 
    7.2 Current Sense  
    The  AC301 -102/106  sensor output voltage read s approximately 2V per 
    A MP  up to a maximum of 10VDC at 5A.  
    Connect this output to a sensor input on the Neutron Controller in 
    order to monitor load levels on the AC line of the AC301 -102/106.  
    7.3 Circuit Breaker Reset  
    The circuit breaker is a push -to -reset 15A circuit breaker. Th e circuit 
    breaker is accessible from the output -side of the unit. In the event the 
    circuit breaker is tripped, do the following:  
     Turn off the AC device's power switch or disconnect the device 
    from the AC301 -102/106  
     Push the circuit breaker reset button bac k in 
     Turn on power or reconnect the AC device  
    Warning! 
    If the circuit breaker trips again, the device is drawing excessive 
    current and should be checked immediately. If necessary, the device 
    may need to be replaced. 
    Check the rating of the device connected  to the  AC301 -102/106 
    Power Sensor/Controller; if it requires a significant amount of power, 
    it should be plugged into its own supply circuit.  
      
    						
    							AC301-102 & AC301-106 User’s Guide 
    400-0536-001   
     
     
     
     
     
    8 
     
    8. Troubleshooting Guide 
    We have carefully tested and have found no problems in the supplied  AC301-102/106 . However, we would like to offer suggestions for the following:  
    Symptom Resolution 
    Output LED  is OFF    The 
    Output  LED only turns on when the AC301 -102/106  Power Sensor/Controller is passing AC power through to 
    the external device. This only occur s when the Neu tron Controller is pulling the Relay Control input of the 
    AC301 -102/106  to ground and +12  VDC is available on the input of the AC301 -102/106 . 
    1.  Check the wiring between th e AC301 -102/106  and  the Neutron Controller.  The AC301 -102/106  requires the 
    following  from the Neutron Controller:  
      a.  +12VDC  to Ground  
      b.  Relay  contact connections between the Relay Control input and Ground  
    2.  Make sure there is +12V present on the AC301 -102/106  input terminal block connector.  If there is +12V, short the 
    Relay Control in put to ground and verify the relay closes and the  AC Output LED turns on. 
    External Device Does Not 
    Turn On   1.
     Make sure the Power Sensor/Controller has +12VDC power applied to the terminal block connector.  
    2.  Make sure the Relay Control input line is conn ected to ground through a relay on the Neutron Controller.  
      If the Relay Control input cannot be verified, short the Relay Control input on the  AC301-102/106  terminal block 
    connector  to the Ground pin on the same connector.  The internal relay "clicks" on a nd provides power to the 
    external device.  
    3.  Verify the AC301 -102/106 input is connected to a working AC outlet and that the outlet is powered.  
      
     
     
      
    						