Have a look at the manual Aluratek POP N PLUG TWOSIDED TOWER FOR WOOD COVER PNP417 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 43 Aluratek manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
PNP415/417 PNP415/417 PNP415/417 PNP415/417/Pop ‘N Plug /Pop ‘N Plug /Pop ‘N Plug /Pop ‘N Plug® with Custom Tabletop Surface with Custom Tabletop Surface with Custom Tabletop Surface with Custom Tabletop Surface User’s Guide 400-0427-004 1 Welcome! We greatly appreciate your purchase of the PNP415/417 Pop ‘N Plug with Custom Tabletop Surface. We are sure you will find it reliable and simple to use. Superior performance for the right price, backe d by solid technical and customer support is what ALTINEX has to offer. We are committed to providing our customers with Signal Management Solutions ® to the most demanding audiovisual installations at very competitive pricing and we welc ome you to join the ranks of our many satisfied customers throughout the wo rld. 1. Precautions and Safety Warnings Please read this manual carefully before using your PNP415/417 Interconnect Box. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your PNP4 15/417 and to prevent fire and shock hazards. Please read them carefully and heed all warnings. 1.1 General · Unauthorized personnel shall not open the unit since th ere are high-voltage components inside. · Qualified ALTINEX service personnel, or their authori zed representatives, must perform all service 1.2 Installation Precautions · For best results, place the PNP415/417 in a dry area a way from dust and moisture. · To prevent fire or shock, do not expose this unit to w ater or moisture. Do not place the PNP415/417 in direct sunlight, near heaters or heat-radiating appliances, or near any liquid. Exposu re to direct sunlight, smoke, or steam can harm internal components . · Handle the PNP415/417 carefully. Dropping or jarrin g can damage the unit. · Never place fingers inside the openings of the unit. This action could cause serious injury due to sharp edges inside the PNP415 /417. · Do not place heavy objects on top of the PNP415/417. Do not use excessive force to push down on the top of the unit. · To turn off the main power, disconnect the power cor d which powers the AC socket on the PNP415/417 pop-up panel. The po wer outlet used should be installed as near to the equipment as possible and should be easily accessible. · ALTINEX recommends using wall outlets with a Ground Fa ult Circuit Interrupter (GFCI) for maximum protection. · Install all cables according to the instructions. Do not force or pull out any cable or power cord that is attached to the PNP4 15/417. 1.3 Cleaning · Surfaces should be cleaned with a dry cloth. Never u se strong detergents or solvents such as alcohol or thinner. Do not use a wet cloth or water to clean the unit. 1.4 FCC Notice · This device complies with Part 15 of the FCC Rules. O peration is subject to the following two conditions: (1) This devi ce may not cause harmful interference, and (2) this device must accep t any interference received, including interference that may cause unde sired operation. · This equipment has been tested and found to comply wit h the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection a gainst harmful interference when the equipment is operated in a co mmercial environment. This equipment generates, uses, and can ra diate radio frequency energy and, if not installed and used in ac cordance with the instructions found herein, may cause harmful interfe rence to radio communications. Operation of this equipment in a re sidential area is likely to cause harmful interference in which case t he user will be required to correct the interference at his own expe nse. · Any changes or modifications to the unit not expressly approved by ALTINEX, Inc. could void the user’s authority to op erate the equipment. 2. Installation Procedures Step 1. Refer to the ALTINEX website, www.altinex.com, to download the latest templates and instructions for tabletop cutting requirements and installation instructions. In order to do this, locate the PNP415 or PNP417 on the website and go to its detail page. The links to the templates, user guide, and more are on the details page. Step 2. Print all information applicable to the inst allation of the PNP415/417, including the templates and any detailed installation instructions. Step 3. Cut an opening into the table’s surface. Thi s operation should be performed by experienced professi onals in order to insure accuracy and to be aesthetically pleasing. Note: Always confirm dimensions before cutting to insu re that specifications have not changed. Step 4. Install the PNP415/417 into the table per th e installation instructions provided on the website. Step 5. Connect all PNP415/417 cables to their appro priate sources and/or destinations. The PNP415/417 is no w ready for operation. 3. Limited Warranty/Return policies Please see the ALTINEX website at www.altinex.com for details on warranty and return policies.
PNP415/417 PNP415/417 PNP415/417 PNP415/417 User’s Guide 400-0427-004 2 4. Technical Specifications Specifications are subject to change. See www.altinex.com for up-to-date information. Features/Description PNP417 Inputs Video (2) 15-pin HD female Audio (2) 3.5mm jack Twisted Pair (4) RJ-45 female Modem (2) RJ-11 female AC Power (4) NEMA 5-15R Outputs Video (2) 15-pin HD male Audio (2) 3.5mm plug Twisted Pair (4) RJ-45 male Modem (2) RJ-11 male AC Power (4) NEMA 5-15P Table 1. PNP415/417 General Mechanical PNP415/417 Min. Table Thickness 0.500 in (13 mm) Max. Table Thickness 1.125 in (29 mm) Diameter 4.950 in (126 mm) Height, above table (open) 4.875 in (124 mm) Height, below table 6.986 in (177 mm) Width 6.000 in (152 mm) Depth 3.817 in (97 mm) Max. weight of custom top 22 oz (0.624 kg) Finish Matte Black T° Operating 10 °C-35 °C T ° Maximum 40 °C Humidity 90% non-condensing Table 2. PNP415/417 Mechanical Electrical PNP415/417 Power Rating (pass through AC power) 120VAC, 60Hz, 5A Table 3. PNP415/417 Electrical
PNP415/417 PNP415/417 PNP415/417 PNP415/417 User’s Guide 400-0427-004 3 5. About Your PNP415/417 · Customizable to almost any table top · Connector plates are fully compatible with PNP400 & PNP500 series · Holds up to eight connector plates · Smooth new look on all sides · Cutout always matches · Round, rectangular, or square cut-out · Simple, slide-in installation · Opens/closes by pressing on top · Gas spring lift mechanism This Pop ‘N Plug uses a custom cut-out tabletop surface and hardware is attached underneath the cutout. When closed, the PNP415/417 lays flat and matches the grain on your table. ALTINEX provides three pre-configured templates for t he PNP415/417 cutouts: round, rectangular, and square. A simple press on the lid closes the unit flush with the tabletop. The PNP415/417 design allows the connector panels to be easily installed. Just remove the top and slide the connector panels into place. In the open position, the PNP415/417 is functional yet maintains a smooth, clean appearance. The PNP417 comes preconfigured with two standard DS90 1-120 sectional plates. Each plate includes the following connections: two AC power, one 15-pin HD (video), two RJ-45 (UTP), one RJ-11 (modem), and one 3.5mm audio. There are two plates and all connectors on the plates are female receptacles. Each signal connector is connected via a 6-foot cable to its corr esponding male plug at the opposite end. The AC power cables are terminated with standard NEMA plugs at the end of 9-foot cords. 15-PIN HD VIDEO3.5 mm AUDIO JACK POWER 120VAC RJ-11 PHONE JACKRJ-45 NETWORK JACK TABLE SURFACE CUSTOM CUTOUT
PNP415/417 PNP415/417 PNP415/417 PNP415/417 User’s Guide 400-0427-004 4 6. Application Diagrams Diagram 1: Typical Setup PNP417 REVERSE SIDE OF PNP417
PNP415/417 PNP415/417 PNP415/417 PNP415/417 User’s Guide 400-0427-004 5 Diagram 2: Cutout Dimensions Diagram 3: Closed Dimensions 4.950 [125.73mm] 5.250 [133.35mm] 7.736 [196.49mm] 6.986 [177.44mm]
PNP415/417 PNP415/417 PNP415/417 PNP415/417 User’s Guide 400-0427-004 6 Diagram 2: Front View Dimensions 3.817 [96.96mm] 4.875 [123.83mm] 4.125 [104.78mm]FRONT VIEW
PNP415/417 PNP415/417 PNP415/417 PNP415/417 User’s Guide 400-0427-004 7 Diagram 3: Side View Dimensions 6.000 [152.40mm] 7.736 [196.49mm] 12.611 [320.32mm] SIDE VIEW
PNP415/417 PNP415/417 PNP415/417 PNP415/417 User’s Guide 400-0427-004 8 7. Operation 7.1 Opening and Closing the PNP415/417 The PNP415/417 will open easily when the top is pressed down and then released. When the PNP415/417 is not in use, simply press the top down until it is level with the surface of the table and then release. The unit will remain hidden until needed again. 7.2 Power/Signal Connections Connect external devices to the appropriate connect or on the PNP415/417. Remember, the devices plugged into the AC power conn ectors should not draw more than 5A AC. 8. Troubleshooting Guide The PNP415/417 unit supplied was carefully tested and no problems were detected. However, we would like to offer the follo wing suggestions: · Please make sure that the highest quality network cabl es are used. · Make sure that no cable or power cord is damaged or p inched. If there has been damage to the unit, do not use the PN P415/417. Please contact ALTINEX at (714) 990-2300 to have the unit repaired.