Home
>
Aluratek
>
Audio-visual interconnect box
>
Aluratek POP N PLUG HYBRID 2SIDED HDMI VGA AUDIO RJ45 POWER PNP408 User Guide
Aluratek POP N PLUG HYBRID 2SIDED HDMI VGA AUDIO RJ45 POWER PNP408 User Guide
Have a look at the manual Aluratek POP N PLUG HYBRID 2SIDED HDMI VGA AUDIO RJ45 POWER PNP408 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 43 Aluratek manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Pop ‘N Plug ® Tower User’s Guide 400-0109-009 1 Welcome! We greatly appreciate your purchase of the PNP400 series Pop ‘N Plug Tower. We are sure you will find it reliable and simple to use. Superior performance for the right price, backed by solid technical and customer support is what ALTINEX has to offer. We are committed to providing our customers with Signal Management Solutions® to the most demanding audiovisual installations at competitive pricing and we welcome you to join the ranks of our many satisfied customers throughout the world. 1. Precautions and Safety Warnings Please read this manual carefully before using your PNP400/PNP408 and keep it handy for future reference. These safety instructions are to ensure the long life of your PNP400/PNP408 and to prevent fire and shock hazards. Please read them carefully and heed all warnings. 1.1 General There are no user serviceable parts inside. Qualified ALTINEX service personnel must perform all service on the PNP400/PNP408. 1.2 Installation Precautions Place the PNP400/PNP408 on a flat, leveled surface in a dry area away from dust and moisture. To prevent fire or shock, do not expose this unit to water or moisture. Do not place in direct sunlight, near heaters, or heat-radiating appliances, or near any liquid. Handle the PNP carefully. Dropping or jarring can cause damage. Do not pull any cables that are attached to the PNP400/PNP408. Do not place heavy objects on top of the PNP400/PNP408. Do not use excessive force to push down on the top of the unit. Do not place fingers inside the unit due to sharp edges inside. To turn off main power, disconnect AC cords from power outlets. Use wall outlets with a Ground Fault Circuit Interrupter (GFCI) for maximum protection. 1.3 Cleaning Unplug the PNP400/PNP408 before cleaning. Clean only with a dry cloth. Never use strong detergents or solvents such as alcohol or thinner. Do not use a wet cloth or water to clean the unit. Do not open the unit to clean. 1.4 FCC Notice This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions found herein, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Any changes or modifications to the unit not expressly approved by ALTINEX, Inc. could void the user’s authority to operate the equipment. 2. Installation Procedures Step 1. Refer to the ALTINEX website, www.altinex.com, to download the latest templates and instructions for tabletop cutting requirements and installation. Search for the PNP400/PNP408 and go to its detail page. The links to the templates, user’s guide, and more are on the left-hand side of the screen. The table can be 0.25-4.0 in (6-102 mm) thick. Step 2. Print all installation information for the PNP400, including the templates and any detailed instructions. Step 3. Mark the table’s surface to indicate the correct positioning of the unit. The face of the unit is typically parallel to the longest sides of the tables. Step 4. Cut an opening into the table’s surface. This operation should be performed by experienced professionals in order to insure accuracy and to be aesthetically pleasing. Always confirm dimensions before cutting to insure that specifications have not changed. Step 5. Lower the PNP400/PNP408 into the opening in the table and make sure the bezel of the unit sits evenly in the table. Step 6. From under the table, insert the mounting brackets into the slots on the side of the unit. See Diagram 6 of the online manual for details. Place the brackets (one on each side) at the desired height for the table thickness and secure them to the bottom of the table using the thumb screws provided. Step 7. Secure the power cord using the cable clamp provided. Pass the power cord (if any) from the bottom of the housing and attach it to the table leaving a service loop beneath the unit. Before tightening the clamp, open and close the unit from the top several times. Set the service loop for smooth operation only. Do not leave excessive cable hanging below the table. Step 8. Secure PNP400/PNP408 signal cables separate from the power cord. All cables should have a service loop to allow the unit to open and close easily. Step 9. Once you have connected power and the proper cables to the unit, you may raise the unit into position by pressing the top of the unit. Step 10. To lower the unit, push on the top of the unit until it locks into place. Do not use excessive force to press down on the pop-up 3. Limited Warranty/Return Policies Please see the ALTINEX website at www.altinex.com for details on warranty and return policies.
PNP400/PNP408 User’s Guide 400-0109-009 2 4. Technical Specifications Specifications are subject to change. See www.altinex.com for up-to-date information. Features/Description PNP PNP 400* Pass-Through AC Power 9-10 ft (2.7-3.0 m) 110 VAC, 60 Hz, 5 A NEMA F-M Number of slots 6 (each side) Compatibility* AC Power (United States) SP2102US, SP2107US AC Power (International) SP2201UK, SP2301CE Audio, Video, and Control SP3201AV, SP3210AV, SP1100SC, and SP3502SC Blank Slot Covers SP1001BL, and SP1002BL Customizable SP3102EP, SP3103EP PNP 408* Audio, Video, Communication 6 ft (2 m) Computer Video 15-pin HD F-M (2) Computer Audio 3.5mm F-M (2) HDMI HDMI F-M (2) Network CAT-6 (RJ-45) F-M (4) USB Type A F-M (4) Pass-Through AC Power 9-10 ft (2.7-3.0 m) 110 VAC, 60 Hz, 5 A NEMA F-M PNP400/ PNP408 Models* Accessories Included Hardware Mounting screws/brackets Cable clamps/screws Fastener T ool Table 1. PNP400/PNP408 General Mechanical PNP400 / 408** Max. T able Thickness 4.00 in (102 mm) Min. T able Thickness 0.25 in (6 mm) Height Above T able (open) 2.909 in (74 mm) Height Below T able Surface 5.760 in (146 mm) Base W idth 6.674 in (170 mm) Base Depth 4.840 in (123 mm) Finish PNP400,PNP408: PNP400S,PNP408S: Matte Black Brushed Aluminum W eight (approx.) PNP400* PNP408* 4.95 lb. (2.25 kg) 8.30 lb. (3.76 kg) Shipping W eight T° Operating 10°C-35°C T° Maximum 50C Humidity 90 non-condensing Table 2. PNP400/PNP408 Mechanical** Electrical (Single outlet panel) PNP400 / PNP408 ** Power Rating (pass-through AC power) 110 VAC, 60 Hz, 5 A Table 3. PNP400/PNP408 Electrical ** ** Dimensions and ratings include models ending in C and S. * Includes models ending in S (brushed aluminum). Models ending in C are customizable.
PNP400/PNP408 User’s Guide 400-0109-009 3 5. About Your PNP400 Dual side connectivity Standard high-quality matte black or brushed aluminum finish Gas spring for smooth operation PNP400/PNP408: Matte Black PNP400S/PNP408S: Brushed Aluminum Simple, drop-in installation Customizable connectors The PNP400/PNP408 Interconnect Tabletop Solution is designed for installation into a conference room table. The PNP400/PNP408 provides a means of connecting audiovisual, network, and power sources into a presentation system. The PNP400/PNP408 can pop up into a raised position to provide access to connectors, or it can be lowered into a table when not in use. The PNP400/PNP408 uses a tower-type construction with a gas spring to raise the interface into position above the tabletop. The PNP400 Interconnect has two openings on either side of the unit for 6 single-slot sectional panels, servicing both sides of a table. Available plates include combinations of audio, analog and digital video, network, USB and AC power connectors, providing extensive flexibility in a convenient package. These sectional plates are easy to install in the field, or can be custom pre-configured at ALTINEX to arrive in a ready-to-go package. The PNP408 is a package that covers the basic needs of many users and ships complete with 2 standard U.S. power receptacles, computer video (15-pin HD) audio (3.5 mm), standard HDMI, 2 network (RJ-45), and 2 USB (Type A) input connectors on each size of unit. All audiovisual connectors have 6 ft. (2 m) cables that feed through to the bottom of the unit. PNP400 PNP408 Front view Back view USB F (x4) RJ4 F Network (x4) HDMI F(x2) 15-pin HD F VGA (x2) AC Power (x4)
PNP400/PNP408 User’s Guide 400-0109-009 4 6. Application Diagrams Diagram 1: Typical Setup
PNP400/PNP408 User’s Guide 400-0109-009 5 Diagram 2: Cutout (Reference not set to scale 1:1)
PNP400/PNP408 User’s Guide 400-0109-009 6 Diagram 3: Top View
PNP400/PNP408 User’s Guide 400-0109-009 7 Diagram 4: Front View
PNP400/PNP408 User’s Guide 400-0109-009 8 Diagram 5: Side View
PNP400/PNP408 User’s Guide 400-0109-009 9 Diagram 6: Mounting
PNP400/PNP408 User’s Guide 400-0109-009 10 Diagram 7: Accessory Installation