Home > Aluratek > Audio-visual interconnect box > Aluratek CABLENOOK WITH US AC POWER AND RETAINING GROMMETS BLACK CNK260 User Guide

Aluratek CABLENOOK WITH US AC POWER AND RETAINING GROMMETS BLACK CNK260 User Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Aluratek CABLENOOK WITH US AC POWER AND RETAINING GROMMETS BLACK CNK260 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 43 Aluratek manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CNK200 
    CNK200  CNK200 
    CNK200 Cable
    CableCable
    Cable-
    --
    -Nook
    NookNook
    Nook
    ®
     Interconnect Box
     Interconnect Box  Interconnect Box
     Interconnect Box 
      
     User’s Guide
    User’s Guide User’s Guide
    User’s Guide 
      
     
    400-0111-005 
     
             
    1 
    Welcome! 
    We greatly appreciate your purchase of the CNK200 Cable-Nook 
    Interconnect Box. We are sure you will find it relia ble and simple to use. 
    Superior performance for the right price, backed by  solid technical and 
    customer support is what ALTINEX has to offer.  
    We are committed to providing our customers with  
    Signal Management Solutions
    ® to the most demanding audiovisual 
    installations at very competitive pricing and we welc ome you to join the 
    ranks of our many satisfied customers throughout the wo rld. 
    1. Precautions and Safety Warnings 
    Please read this manual carefully before using your CNK200 Cable-Nook 
    Interconnect Box. Keep this manual handy for future  reference. These safety 
    instructions are to ensure the long life of your CNK2 00 and to prevent fire 
    and shock hazards. Please read them carefully and heed  all warnings. 
    1.1 General  · 
    Qualified ALTINEX service personnel or its authorized  representative 
    must perform all service. 
    1.2 Installation  ·  
    For best results, place the CNK200 Cable-Nook Intercon nect Box in a 
    dry area away from dust and moisture. 
    ·  To prevent fire or shock, do not expose this unit to w ater or moisture. 
    Do not place the CNK200 in direct sunlight, near he aters or 
    heat-radiating appliances, or near any liquid. Exposu re to direct 
    sunlight, smoke, or steam can harm internal components . 
    · Handle the CNK200 carefully. Dropping or jarring ca n damage the unit. 
    · Never place fingers inside the openings in the back o f the unit. This 
    action could cause serious injury because of the sharp  edges inside.  
    · Do not place heavy objects on top of the CNK200. 
    · Install all cables according to the instructions. 
    1.3 Cleaning · 
    Clean surfaces with a dry cloth. Never use strong dete rgents or solvents 
    such as alcohol or thinner. Do not use a wet cloth or  water to clean the 
    unit. 
    1.4  FCC Notice ·  
    This device complies with Part 15 of the FCC Rules. O peration is 
    subject to the following two conditions: (1) This devi ce may not cause 
    harmful interference, and (2) this device must accep t any interference 
    received, including interference that may cause unde sired operation. 
    · This equipment has been tested and found to comply wit h the limits for 
    a Class A digital device, pursuant to Part 15 of the  FCC Rules. These 
    limits are designed to provide reasonable protection a gainst harmful 
    interference when the equipment is operated in a co mmercial 
    environment. This equipment generates, uses, and can ra diate radio 
    frequency energy and if not installed and used in acc ordance with 
    instructions found herein, may cause harmful interfe rence to radio 
    communications. Operation of this equipment in a re sidential area is 
    likely to cause harmful interference in which case t he user will be 
    required to correct the interference at his own expe nse. 
    · Any changes or modifications to the unit not expressly  approved by 
    ALTINEX, Inc. could void the user’s authority to op erate the 
    equipment. 
     
     
     
    2. Installation Procedures 
    WARNING:  ALTINEX recommends using an experienced prof essional to make the table cutout. Before starting, go to the ALTINEX website at 
    www.altinex.com and download the latest table cutout requirements, t emplates, and detailed installation instructions with diagrams. 
    Step 1.  Cut an opening into the table for the CNK20 0. Use the template and measurements provided on the A LTINEX website. The CNK200 is designed to fit 
    tabletops 0.5 - 3.5 in (13-89 mm) thick. 
    Step 2.  Insert the CNK200 into the table cutout and  secure it to the table using the 
    brackets and thumb screws provided.  
    Step 3.  Prepare cables for use with the CNK200. When  using retaining brackets to 
    hold cables in place, it is important to adjust the r etaining brackets close 
    enough together to prevent the cables from falling,  but loose enough to 
    allow the cables to be pulled up easily.  The cables  should be long enough to 
    be pulled up through the CNK200 and reach the equip ment. 
       If using preconfigured or customizable sectional pla tes, the cables need only 
    be long enough to mate with the cables/connectors on  the plates. 
    Step 4.  If desired, bundle like cables together using  a protective sheath, meshed 
    sleeve, etc.  Leave the free ends of the cables long  enough for making 
    connections to the equipment on the table. 
    Step 5.  Route the cables through the bottom of the u nit to the top. Use the cable 
    clamps provided to neatly route and secure the cable s to the bottom of the 
    table. 
    3. Limited Warranty/Return policies 
    Please see the ALTINEX website at www.altinex.com for  details on warranty and return policies. 
    SURFACETABLE
       
    						
    							CN
    CNCN
    CNK200 
    K200 K200 
    K200 Interconnect Box
    Interconnect BoxInterconnect Box
    Interconnect Box 
      
     User’s Guide
    User’s Guide User’s Guide
    User’s Guide 
      
     
    400-0111-005 
     
            
    2 
    4. Technical Specifications 
    Specifications are subject to change. See www.altinex.com for up-to-date information. 
     
    Features/Description  CNK200 
    Inputs  
      Video/Audio n/a 
    Outputs  
      Video/Audio n/a 
    Compatibility   
      Cable-Nook Standard and  
      Customizable Plates     CN5000 Series, 
       CNK-IP-100 Series 
      Snap-In Connectors 
       All ALTINEX Snap-In  
       Connectors 
    Accessories Included   
      Mounting Hardware    Thumb Screws (2),   
       Mounting Brackets (2) 
    Table 1. CNK200 General  
    Mechanical 
    CNK200 
    Hole Sets   23 
    Minimum Table Thickness  0.5 in (13 mm) 
    Maximum Table Thickness  3.5 in (89 mm) 
    Housing Dimensions   
       Height 4.7 in (119 mm) 
       Width 6.0 in (153 mm) 
       Depth 4.7 in (119 mm) 
    Bezel Dimensions (surface)   
       Width 7.9 in (200 mm) 
       Depth 6.5 in (166 mm) 
    Color  Black 
    Material Aluminum 
    T° Operating  10°C-35 °C 
    T ° Maximum  50°C 
    Humidity 
    90% non-condensing 
    MTBF (calculations)  40,000 hrs (min.) 
    Table 2. CNK200 Mechanical      
    						
    							CN
    CNCN
    CNK200 
    K200 K200 
    K200 Interconnect Box
    Interconnect BoxInterconnect Box
    Interconnect Box 
      
     User’s Guide
    User’s Guide User’s Guide
    User’s Guide 
      
     
    400-0111-005 
     
            
    3 
     
    5. About Your CNK200  · 
    Installs easily into tabletop  
    · Convenient access to cables  
    · Simple, cost-effective interconnect solution  
    · Fits table surfaces 0.5 - 3.5 in (13 - 89 mm) thick 
    The CNK200 is a simple, effective way of hiding/storin g multimedia cables and connectors and is designed for  boardrooms and conference rooms. Cables remain 
    connected to a presentation system enabling the user to  access connections to AC power, video, audio, and other media sources. 
    The cables connected to the presentation system under neath the surface can be accessed from the CNK200 by e ither pulling the cables up and out of the top of 
    the unit (using retaining brackets) or by plugging ex ternal cables into sectional plates installed in the CNK200.  
    Retaining brackets secure cable ends where the brack ets can be adjusted to fit a wide variety of cable sizes.  Cables are pulled out from the top of the CNK200  
    when needed and then fed back down under the table  when no longer required. The weight of the cables helps to feed the slack through the unit and the cable 
    ends are kept from falling by the retaining brackets.   
    The CNK200 sectional plates allow for diverse connecto r configurations. Available plates include combinations of audio, video, computer, and AC power 
    connectors, providing extensive flexibility in a con venient package. The sectional plates connect permane ntly to the presentation system. 
    The CNK200 Cable-Nook is designed for use with tables  ranging from half an inch to 3.5 in thick. The height of the interior shelf can also be adjusted for 
    different depths. The CNK200 comes in a standard matte  black color, or the top of the unit can be finished to match a table on a custom per order basis at an 
    additional charge.      
    MOUNTING BRACKET
    ACCESS DOOR
    BEZEL
    HOUSING
    SUPPORTS
    ADJUSTABLE
    SHELF HOLES
    SAMPLE CONFIGURATION: RETAINING BREACKETS
    and CUSTOM PLATES
         
    						
    							CN
    CNCN
    CNK200 
    K200 K200 
    K200 Interconnect Box
    Interconnect BoxInterconnect Box
    Interconnect Box 
      
     User’s Guide
    User’s Guide User’s Guide
    User’s Guide 
      
     
    400-0111-005 
     
            
    4 
    6. Application Diagrams  
    Diagram 1: Typical Setup 
       
             
    						
    							CN
    CNCN
    CNK200 
    K200 K200 
    K200 Interconnect Box
    Interconnect BoxInterconnect Box
    Interconnect Box 
      
     User’s Guide
    User’s Guide User’s Guide
    User’s Guide 
      
     
    400-0111-005 
     
            
    5 
    Diagram 2: Dimensions Top and Front 
       
    6.0
     [153 mm]
    4.7
    [119 mm]
    6.5
     [166 mm]
    7.9
     [200 mm]
       
    						
    							CN
    CNCN
    CNK200 
    K200 K200 
    K200 Interconnect Box
    Interconnect BoxInterconnect Box
    Interconnect Box 
      
     User’s Guide
    User’s Guide User’s Guide
    User’s Guide 
      
     
    400-0111-005 
     
            
    6 
    Diagram 3: Side View Dimensions 
       
    4.7
     [119 mm]
    5.3
     [134 mm]
    3.9
     [100 mm]
    4.7
    [119 mm]
    6.0
     [153 mm]
       
    						
    							CN
    CNCN
    CNK200 
    K200 K200 
    K200 Interconnect Box
    Interconnect BoxInterconnect Box
    Interconnect Box 
      
     User’s Guide
    User’s Guide User’s Guide
    User’s Guide 
      
     
    400-0111-005 
     
            
    7 
    Diagram 4: Cutout 
       
    4x R.500
     [R12.70mm]
    FRONT FRONT
    7.360
     [186.94 mm]
    6.030
     [153.16 mm]
       
    						
    							CN
    CNCN
    CNK200 
    K200 K200 
    K200 Interconnect Box
    Interconnect BoxInterconnect Box
    Interconnect Box 
      
     User’s Guide
    User’s Guide User’s Guide
    User’s Guide 
      
     
    400-0111-005 
     
            
    8 
    Diagram 5: Twenty-Three (23) Hole Sets 
    The CNK200 can be customized for virtually any configuration required. Inside, there are 23 hole sets available for installing preconfigured plates, customizable 
    plates, or retaining brackets for holding cables.   
    In some cases, it is desirable to have the cables reside  in the Cable-Nook instead of requiring the user to provide their own cables. In this case, retaining brackets 
    can be positioned to keep cables installed under the t able from falling below the Cable-Nook’s interior she lf. The user simply pulls out the cable(s) needed and 
    connects them to a laptop, iPod, etc. 
    Shown below are some typical plate options with reta ining brackets. See our website at 
    www.altinex.com for a complete list of available plates and customizable 
    snap-in connectors.      
    23 HOLE SETS
    WITH LID OPEN
    TOP INSIDE VIEW
    RETAINING
    BRACKETS PLATES
    POWER
    CUSTOMIZABLE
    SNAP-IN PLATES
    TO HOLD CABLES
    STANDARD
    PLATES
       
    						
    							CN
    CNCN
    CNK200 
    K200 K200 
    K200 Interconnect Box
    Interconnect BoxInterconnect Box
    Interconnect Box 
      
     User’s Guide
    User’s Guide User’s Guide
    User’s Guide 
      
     
    400-0111-005 
     
            
    9 
    Diagram 6: Mounting 
       
    MOUNTING BRACKETS
    THUMB SCREWS
    Place the mounting 
    brackets on the  
    mounting supports as  shown in Detail A.
    Insert the CNK200 
    through the opening in  
    the table.
    1
    2
    MOUNTING HARDWARE 
    MOUNTING EXAMPLE
    TABLE SURFACE
    Detail A
    Insert and tighten thumb screws as shown until 
    the housing is secured  
    to the surface.3
       
    						
    							CN
    CNCN
    CNK200 
    K200 K200 
    K200 Interconnect Box
    Interconnect BoxInterconnect Box
    Interconnect Box 
      
     User’s Guide
    User’s Guide User’s Guide
    User’s Guide 
      
     
    400-0111-005 
     
            
    10 
    7. Operation  
    7.1 Accessing the CNK200 
    The CNK200 cover opens easily and remains open until all the cables are 
    connected. The cover should be closed with the cable s routed through the 
    curved opening to prevent damage to the unit and to  prevent liquids from 
    entering the opening.   
    Additionally, the cover should be closed when not in  use to prevent liquids 
    or other debris from damaging the unit. 
    7.2 Power/Signal Connections 
    Connect external devices to the appropriate connect or from the CNK200.  
    Remember, the devices plugged into the AC power conn ectors should not 
    draw more than the rated values of the cables and/or  circuit. 
     
    8. Troubleshooting Guide 
    The CNK200 supplied was carefully tested and no proble ms were detected. 
    However, we would like to offer the following suggest ions: 
    · Please make sure that the highest quality network cabl es are used.  
    · Make sure that no cable or power cord is damaged or p inched. If 
    there has been damage, do not use the CNK200. Please  call the 
    ALTINEX Customer Service Department at (714) 990-230 0 to have 
    the unit repaired.  
       
    						
    All Aluratek manuals Comments (0)

    Related Manuals for Aluratek CABLENOOK WITH US AC POWER AND RETAINING GROMMETS BLACK CNK260 User Guide