    Have a look at the manual Aluratek 3 EMPTY SNAPIN PORTS INSERT PLATE FOR CNK200 CN5013EP User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 43 Aluratek manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CN5008US
    CN5008US CN5008US
    CN5008US/
    //
    /DUAL AC POWER MODULE FOR CABLE
    DUAL AC POWER MODULE FOR CABLE DUAL AC POWER MODULE FOR CABLE
    DUAL AC POWER MODULE FOR CABLE-
    --
    -NOOK
    NOOKNOOK
    NOOK 
      
     User’s Guide 
      
     
    400-0561-001 
     
             
    1
    Installation Options 
     
    Welcome! 
    We greatly appreciate your CN5008US. We are sure you will find it reliable 
    and simple to use. Superior performance for the rig ht price, backed by solid 
    technical and customer support is what ALTINEX has  to offer. 
    We are committed to providing our customers with Si gnal Management 
    Solutions
    ® to the most demanding audiovisual installations at  competitive 
    pricing and we welcome you to join the ranks of our  many satisfied customers 
    throughout the world. 
    1. Precautions and Safety Warnings 
    Please read this manual carefully before using your  CN5008US. Keep this 
    manual handy for future reference. These safety ins tructions are to ensure the 
    long life of your CN5008US and to prevent fire and  shock hazards. Please read 
    them carefully and heed all warnings. 
    1.1 General  ·  
    There are no user serviceable parts inside. Qualifi ed ALTINEX service 
    personnel must perform all service. 
    1.2 Handling  ·  
    To prevent fire or shock, do not expose this unit t o water or moisture. 
    Do not place the CN5008US in direct sunlight, near  heaters, or 
    heat-radiating appliances, or near any liquid. Expo sure to direct sunlight, 
    smoke, or steam can harm internal components. 
    ·  Handle the unit carefully. Dropping or jarring can  cause damage. 
    · Do not pull any cables that are attached to the CN5 008US. 
    · Do not place heavy objects on top of the CN5008US. 
    1.3 Cleaning  · 
    Unplug the CN5008US before cleaning. 
    · Clean only with a dry cloth. Never use strong deter gents or solvents such 
    as alcohol or thinner. Do not use a wet cloth or wa ter to clean the unit. 
    Do not open the unit to clean. 
    1.4 FCC Notice ·  
    This device complies with Part 15 of the FCC Rules.  Operation is subject 
    to the following two conditions: (1) This device ma y not cause harmful 
    interference, and (2) this device must accept any i nterference received, 
    including interference that may cause undesired ope ration. 
    · This equipment has been tested and found to comply  with the limits for 
    a Class A digital device, pursuant to Part 15 of th e FCC Rules. These 
    limits are designed to provide reasonable protectio n against harmful 
    interference when the equipment is operated in a co mmercial 
    environment. This equipment generates, uses, and ca n radiate radio 
    frequency energy and if not installed and used in a ccordance with 
    instructions found herein, may cause harmful interf erence to radio 
    communications. Operation of this equipment in a re sidential area is 
    likely to cause harmful interference in which case  the user will be 
    required to correct the interference at his own exp ense. 
    · Any changes or modifications to the unit not expres sly approved by 
    ALTINEX, Inc. could void the user’s authority to op erate the equipment. 
     
     
    2. Installation Procedures 
    The CN5008US can be installed inside a Cable-Nook o r into furniture horizontally or vertically as shown. Typically, 
    furniture units are installed in a tabletop, but ca n be installed inside a desk or podium. 
    Note:  Download and read the entire online manual to  become familiar with the CN5008US.  
    Step 1.  Locate the best position for the CN5008US.  
    Step 2.  If installing in furniture, prepare the cut out for the table.  
    Warning:  ALTINEX recommends using an experienced pr ofessional to make the table cutout in order to 
    insure accuracy and to be aesthetically pleasing. 
    Step 3.  Install the CN5008US into the Cable-Nook op ening or tabletop. 
    Tabletop:  Route the power cord down through the ope ning in the tabletop. Fasten the CN5008US to the 
    surface using the appropriate screws. 
    Cable-Nook:  Route the power cord down through the o pening in the Cable-Nook. Fasten the CN5008US to 
    the surface using the 4 screws provided with the un it. The CN5008US requires 6 hole sets of the 
    23 total hole sets available in the Cable-Nook. 
       
    3. Limited Warranty/Return Policies 
    Please see the ALTINEX website at www.altinex.com for details on warranty and return policies.    
    						
    							CN5008US
    CN5008US CN5008US
    CN5008US 
      
     User’s Guide 
      
     
    400-0561-001 
     
             
    2
    4. Technical Specifications 
    Specifications are subject to change. See www.altinex.com for up-to-date information. 
     
    Features/Description  CN5008US 
    Pass-Through AC Power 9-10 ft (2.7 to 3.0 m) 
      120 VAC, 60 Hz, 12 A   NEMA F (2) 
    NEMA M (1) 
    Compatibility   
      Cable-Nook Series  Requires 6 hole sets * 
    Agency Approvals   
      UL Listed   File E254082 
      Saf ety UL, CUL 
    Accessories Included   
      Hardware  Mounting screws 
     
    Table 1. CN5008US General  
    Mechanical  CN5008US 
    Material/Color  0.05 in Al, Black 
    Height (face plate)  4.49 in (114.1 mm) 
    Height (body only)  3.54 in (89.9 mm) 
    W idth 1.36 in (34.5 mm) 
    Depth ** 1.75 in (44.5 mm) 
    Net W eights   1.3 lb (0.59 kg) 
    Shipping W eights (approximate)  2.0 lb (0.9 kg) 
    T° Operating  10 °C-35 °C 
    T ° Maximum  50°C 
    Humidity 
    90% non-condensing 
      
    Table 2. CN5008US Mechanical       
    Electrical  CN5008US 
    Pass-Through AC  
      (total through both receptacles) 1440 W  max. 
     
    Table 3. CN5008US Electrical 
    **  Dimension does NOT include power cord or strain re
    lief outside of 
    enclosure. Strain relief extends approximately 1.1  in (28 mm) outside 
    edge of enclosure and does not include bend radius  of power cord. *  The Cable-Nook has a total of 23 hole sets for cus tom modules.   
    						
    							CN5008US
    CN5008US CN5008US
    CN5008US 
      
     User’s Guide 
      
     
    400-0561-001 
     
             
    2
     
    5. About Your CN5008US · 
    UL Listed for US and Canada 
    · 12A load capacity 
    · Compact and easy to install 
    · Two standard AC power outlets for U.S. , Canada , M exico, or Japan 
    · Comes with 9 ft (3 m) cable terminated with a singl e male plug 
    · Covers 6-screwhole sets of the Cable Nook. 
    The ALTINEX CN5008US Dual AC Power Module is design ed for use inside ALTINEX's Cable-Nook series of interconnect boxes, but can also be installed 
    directly into furniture. The Cable-Nook is designed  for boardrooms and conference rooms where it provi des a simple and effective means of hiding/storing 
    multimedia cables and connectors. The cables remain  connected to a presentation system enabling the user to access connections to video, audio, and other 
    media sources. The modular Cable-Nook uses a half-m oon lid that remains flush with the table when not in use.  
    The CN5008US module provides safe, ample AC power f or users to power laptops, projectors, or other presentation equipment.  
    To access the CN5008US power module inside the Cabl e-Nook, simply lift the door and plug in to the AC receptacles the same as any other AC power outlet.  The 
    lid closes easily even with several cables in use.   
                  
    						
    							CN5008US
    CN5008US CN5008US
    CN5008US 
      
     User’s Guide 
      
     
    400-0561-001 
     
             
    3
    6. Application Diagrams  
    Diagram 1: Typical Setup 
       
        
    						
    							CN5008US
    CN5008US CN5008US
    CN5008US 
      
     User’s Guide 
      
     
    400-0561-001 
     
             
    4
    Diagram 2: Dimensions 
                                       
    						
    							CN5008US
    CN5008US CN5008US
    CN5008US 
      
     User’s Guide 
      
     
    400-0561-001 
     
             
    5
    7. Operation 
    The CN5008US requires no adjustments for optimum performance.  
    Once installed, the CN5008US will work trouble-free  without user intervention.  
     
    8. Troubleshooting Guide 
    We have carefully tested and found no problems in t he supplied CN5008US; however, if you experience an y problems or have questions, call ALTINEX at 