    We greatly appreciate your purchase of your Tilt N Plug Jr. (TNP 
    JR.) Interconnect Box. We are sure you will find it reliable and 
    simple to use. Superior performance for the right price, backed by 
    solid technical and customer support is what Altinex offers. 
    We are committed to providing Signal Management Solutions® to 
    our customers for the most demanding audiovisual installations at 
    competitive pricing and we welcome you to join the ranks of our 
    many satisfied customers throughout the world. 
    1. Precautions and Safety Warnings 
    Please read this manual carefully before using your Tilt 
    N Plug Jr. Interconnect Box. Keep this manual handy for future 
    reference. These safety instructions are to ensure the long life of 
    your Tilt N Plug Jr. and to prevent fire and shock hazards. Please 
    read them carefully and heed all warnings. 
    1.1 General 
     Unauthorized personnel shall not open the unit as there are 
    high-voltage components inside. Qualified Altinex personnel 
    or their authorized representatives must perform all service. 
    1.2 Installation Precautions 
     For best results, place in a dry area away from dust. 
     To prevent fire or shock, do not expose to water or 
    moisture. Do not place in direct sunlight, near heaters or 
    heat-radiating appliances, or near any liquid. Exposure to 
    direct sunlight, smoke, or steam can harm components. 
     Handle carefully; dropping or jarring can damage the bezel. 
     Never place fingers inside the opening on either side of the 
    unit; injury can occur due to sharp edges inside. 
     Do not place heavy objects on top of the TNP Jr. Do not 
    use excessive force to push down on the top of the unit. 
     Disconnect the power cord to turn off power; this powers 
    the socket on the pop-up panel. The power outlet should be 
    installed near the equipment and be easily accessible. 
     We recommend using wall outlets with a Ground Fault 
    Circuit Interrupter (GFCI) for maximum protection. 
     Install all cables according to the instructions herein. Do not 
    force or pull any cable that is attached to the TNP Jr. 
    1.3 Cleaning 
     Surfaces should be cleaned with a dry cloth. Never use 
    strong detergents or solvents such as alcohol or thinner. Do 
    not use a wet cloth or water to clean the unit. 
    1.4 FCC Notice 
     This device complies with Part 15 of the FCC Rules. 
    Operation is subject to the following two conditions: (1) This 
    device may not cause harmful interference, and (2) this 
    device must accept any interference received, including 
    interference that may cause undesired operation. 
     This equipment has been tested and found to comply with 
    the limits for a Class A digital device, pursuant to Part 15 of 
    the FCC Rules. These limits are designed to provide 
    reasonable protection against harmful interference when 
    the equipment is operated in a commercial environment. 
    This equipment generates, uses, and can radiate radio 
    frequency energy and, if not installed and used in 
    accordance with the instructions found herein, may cause 
    harmful interference to radio communications. Operation of 
    this equipment in a residential area is likely to cause 
    harmful interference in which case the user will be required 
    to correct the interference at his expense. 
     Any changes or modifications to the unit not expressly 
    approved by Altinex, Inc. could void the user’s authority to 
    operate the equipment. 
     
    2. Installation Procedures 
    Step 1. Cut an opening into the table’s surface. Refer to the Altinex website at www.Altinex.com for table cutout requirements. 
    Note: The table can be 2.25” thick or less. Always confirm dimensions before cutting to insure specifications have not changed.  
    Step 2. Insert the Tilt N Plug Jr. into the table cutout.  
    Step 3. Place the support brackets under the table and place them between the 
    support mount grooves on the side of the unit. Attach brackets to the groove at 
    and secure them to the table using the knurled screws. Tighten provided 
    wing nuts to secure screws on place. 
    Step 4. Secure the cables using the provided cable clamps and screws. Pass the 
    power cord from the bottom of the housing and attach it to the table using the 
    cable clamp and screw supplied with the TNP Jr.  Leave enough slack in the 
    service loop to allow for easy opening and closing, but not too much as to 
    cause excess drooping of the service loop. 
    Step 5. Connect the appropriate cables with the correct input connectors on the 
    bottom of the unit.  
    Step 6. Once you have applied power and connected the proper cables on the bottom of the unit you may raise the unit by pushing 
    down on the front of the top cover. The latching mechanism releases and the unit raises into position. To lower the unit, push 
    on the top of the TNP Jr. until it locks into place. 
    3. Limited Warranty/Return Policies 
    Please see the Altinex website at www.Altinex.com for details on warranty and return policies.  
    						
    							Tilt N Plug Jr. Interconnect Box User’s Guide 
    400-0434-014  
     
     
     
     
     
    2 
     
    4. Technical Specifications 
    Specifications are subject to change. See www.Altinex.com for up-to-date information. 
    Features/Description TNP Jr. 
    TNP 121 * 
    Audio, Video, Communication * 6 ft. (2 m) 
      Computer Video 15-pin HD F-M (1) 
      Stereo Audio 3.5 mm F-M (1) 
      Network CAT-6 RJ-45 F-M (1) 
      Modem RJ-11 F-M (1) 
    Agency Approval  
      UL/C-UL Listed File E254082 
    TNP 125 * 
    Audio, Video, Communication 6 ft. (2 m) 
      Computer Video HDMI F-M (1) 
      Computer Audio 3.5mm F-M (1) 
      Network CAT-6 (RJ-45) F-M (1) 
      USB  USB Type A F-M (1) 
    Agency Approval  
      UL/C-UL Listed File E254082 
    TNP 128 * 
    Audio, Video, Communication 6 ft. (2 m) 
      Computer Video 15-pin HD F-M (1) 
      Computer Audio 3.5mm F-M (1) 
      HDMI® HDMI F-M (1) 
      Network CAT-6 (RJ-45) F-M (1) 
    Agency Approval  
      UL/C-UL Listed File E254082 
    TNP 151 * 
    Audio, Video, Communication * 6 ft. (2 m) 
      Network CAT-6 (RJ-45) F-M (2) 
    Agency Approval  
      UL/C-UL Listed File E254082 
    TNP 155 * 
    Audio, Video, Communication* 6 ft. (2 m) 
      USB  USB Type A F-M (2) 
    Agency Approval  
      UL/C-UL Listed File E254082 
     All TNP   Jr. Models * 
    Pass-Through AC Power 9-10 ft. (2.7-3.0 m) 
      120 VAC, 60 Hz, 12 A NEMA F-M 
    Accessories Included  
      Hardware 
      -Mounting 
    screws/nuts/brackets 
      -Cable clamps/screws 
      USB Wall Adapter 
    (PS5594UB)  -TNP155 accessory only 
    Table 1. TNP Jr. General 
     Mechanical All TNP Jr. Models ** 
      Max. Table Thickness 2.25 in (57 mm) 
      Height, opened 5.5 in (140 mm) 
      Width    4.6 in (117 mm) 
      Depth  4.9 in (124 mm) 
      Weight (approx.) 2.8 lb. (1.3 kg) 
      Shipping Weight 4.5 lb. (2.0 kg) 
      Finish Standard:  Models ending in S:  Matte Black  Brushed Aluminum 
      T° Operating  (T° Max) 10°C-35°C  (40°C) 
      Humidity 90 non-condensing 
    Table 2. Mechanical ** 
     Electrical    (Single outlet panel) All TNP Jr. Models ** 
      Power Rating      (pass-through AC power) 120VAC, 60Hz, 12A Total Current 
    Table 3. Electrical ** 
     
     
     
     
     
     
     
     
     
     
     
       
    * Models ending in C are customizable for  
     round bezel 
     stackable (2,3,4 up) 
     mirror surface. 
    Models ending in S have brushed aluminum finish.  
    Models ending in W are designed for use in kitchens, bathrooms 
    and countertops. 
     
    ** Dimensions and ratings include the customizable C models, 
    “S” models and “W” models. 
     
     
     Note: HDMI, the HDMI Logo, and High-Definition Multimedia Interface are trademarks or registered trademarks of HDMI 
    Licensing LLC in the United States and other countries.   
    						
    							Tilt N Plug Jr. Interconnect Box User’s Guide 
    400-0434-014  
     
     
     
     
     
    3 
     
    5. About Your Tilt N Plug Jr. Interconnect Box 
    All Tilt N Plug Jr. products belong to a family of compact interconnection 
    solutions designed for installation into a table as part of a presentation 
    system. They are designed for mounting into a table, podium, or other 
    furniture to provide a way of connecting audiovisual equipment on top of 
    the furniture to a presentation system below the furniture.  
    All use the same core element; a multimedia input plate that can be 
    tilted open when needed and pushed closed when not needed.  
    All signals pass through the input plate directly to cables on the 
    underside of the table with no intervening circuitry. The use of additional 
    Altinex Signal Management Solutions such as computer video interfaces, 
    distribution amplifiers, and switchers may be desirable. 
    The input plate of the Tilt N Plug Jr. is accessible by pushing down on 
    the top cover. The unit then auto-tilts open with help from an internal 
    pneumatic spring. Once open, the input plate remains securely in place. 
    The input plate is hidden by pressing down on the top cover until the latching mechanism engages. In its closed position, the top panel 
    lies flush with the tabletop, held in place by the latching mechanism. 
    All Tilt N Plug Jr. Signal Management Solutions come with a standard top and bezel offering a high quality matte black finish. Models 
    ending in S come with a brushed aluminum finish. Other finishes or special bezel configurations, including round bezels 
    (CM1293/CM12394) and black mirrored bezel (CM1271) are available upon request. Please contact an Altinex representative to 
    discuss custom options.  
    Stackable bezels are available in 2- (CM12462), 3- (CM12463), or 4- (CM12464) space configurations. These bezel frames enable 
    integrators to select any units from the TNP Jr. or CNK Jr. families to configure an interconnect box system easily tailored to the 
    customer’s requirements. Our new mounting frames make it easy to stack two interconnect boxes together using a dual frame. The 
    interconnects can face the same or opposite sides of the table. The 3up and 4up frames can be customized the same way, with 
    individual interconnects facing whichever side of the table the customer requires.  Integrators can now select any of the TNP Jr. or CNK 
    Jr. units and specify these new stackable bezels to create a unique, multiple table top interconnect solution. Select from dual power 
    with USB charging, HDMI or VGA ports, or USB and network. Anything required for the most sophisticated meeting rooms can be 
    installed into the new Altinex stackable frames. 
    Models ending in W come with the added safety GFCI plug and are UL listed for use in kitchens, bathrooms, and countertops.  They 
    can be safely installed into custom kitchen counters, bars, or any other location where water is typically splashed. The result is greater 
    installation flexibility for AV integrators and enhanced safety for end users that is backed by UL’s rigorous safety standards 
     
     
      
    TNP128 Shown here  
    						
    							Tilt N Plug Jr. Interconnect Box User’s Guide 
    400-0434-014  
     
     
     
     
     
    4 
     
    Faceplates for the TNP Jr. Interconnect Boxes 
     
     
     
     
      
    						
    							Tilt N Plug Jr. Interconnect Box User’s Guide 
    400-0434-014  
     
     
     
     
     
    5 
     
    6. Application Diagrams 
    Diagram 1: Single Unit Dimensions  
    (TNP121, TNP125, TNP128, TNP151, and TNP155 - includes models ending in C, S, and W) 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    Diagram 2: Custom TNP Jr.  Unit with round bezel Dimensions 
    (TNP121, TNP125, TNP128, TNP151, and TNP155 - includes models ending in C, S & W) 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
      
      TNP121 Faceplate Shown Here 
      
     TNP121 Faceplate Shown Here 
     
     
      
    						
    							Tilt N Plug Jr. Interconnect Box User’s Guide 
    400-0434-014  
     
     
     
     
     
    6 
     
     
    Diagram 3: Stackable bezels Dimensions 
    Can be used with TNP121, TNP125, TNP128, TNP151, and TNP155 - includes models ending in C & W) 
     
        
    						
    							Tilt N Plug Jr. Interconnect Box User’s Guide 
    400-0434-014  
     
     
     
     
     
    7 
     
     
    Diagram 4: TNP128 Application Diagram 
     
     
    Diagram 5: TNP155 Application Diagram 
     
       
    						
    							Tilt N Plug Jr. Interconnect Box User’s Guide 
    400-0434-014  
     
     
     
     
     
    8 
     
    7. Operation 
    7.1 Opening and Closing the Tilt N Plug Jr. 
    The Tilt N Plug Jr. will open easily when the top is pressed down 
    and then released. 
    When the Tilt N Plug Jr. is not in use, simply press the top down 
    until it is level with the surface of the table and then release.  The 
    unit will remain hidden until needed again.  
    7.2 Power/Signal Connections 
    Connect external devices to the appropriate connector on the Tilt 
    N Plug Jr. Remember, the devices plugged into the AC power 
    connectors should not draw more than 12A AC. 
     
    8. Troubleshooting Guide 
    The Tilt N Plug Jr. supplied was carefully tested and no 
    problems were detected. However, we would like to offer the 
    following suggestions: 
     Please make sure that the highest quality network 
    cables are used.  
     Make sure that no cable or power cord is damaged or 
    pinched. If there has been damage, do not use the Tilt 
    N Plug Jr. Please call the Altinex Customer Service 
    Department at (714) 990-2300 to have the unit repaired.  
     If the unit does not rise into position correctly, check the 
    service loops for the signal and power cords on the 
    bottom of the unit.  
     
      
    						
    All Altinex manuals Comments (0)

    Related Manuals for Altinex TILT N PLUG JR TNP120C User Guide