Have a look at the manual Altinex TILT N PLUG INTERNATIONAL TABLETOP INTERCONNECT BOX TNP461 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 18 Altinex manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Tilt ‘N Plug® Jr. Interconnect Boxes User’s Guide 400-0623-001 1 Welcome! We greatly appreciate your purchase of the TNP461. We are sure you will find it reliable and simple to use. Superi or performance for the right price, backed by solid technical and customer support is what Altinex has to offer. We are committed to providing our customers with Si gnal Management Solutions ® to the most demanding audiovisual installations at competitive pricing and we welcome you to join the ranks of our many satisfied customers throughout th e world. 1. Precautions and Safety Warnings Please read this manual carefully before using your TNP461. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your TN P461 and prevent fire and shock hazards. Please read them ca refully and heed all warnings. 1.1 General · Qualified Altinex service personnel or their autho rized representatives must perform all service. 1.2 Installation Precautions · Place the Tilt ‘N Plug Jr. in a dry area away from dust. · Handle the TNP Jr. carefully. Dropping or jarring can damage the bezel. · To prevent fire or shock, do not expose this unit to water or moisture. Do not place in direct sunlight, near heaters or heat-radiating appliances, or near any liquid. E xposure to direct sunlight, smoke, or steam can harm intern al components. · Never place fingers inside the opening on either s ide of the unit. This could cause injury due to sharp edge s. · Do not place heavy objects on top of the TNP Jr. D o not use excessive force to push down on the top of the unit. · Disconnect the power cord to turn off the main pow er. This supplies power to the power socket on the pop up panel. The power outlet should be installed near th e equipment and should be easily accessible. · We recommend using outlets with a Ground Fault Cir cuit Interrupter (GFCI) for maximum protection. · Install all cables according to the instructions f ound herein. Do not force or pull cables or power cords. 1.3 Cleaning · Surfaces should be cleaned with a dry cloth. Never use strong detergents or solvents such as alcohol or th inner. Do not use a wet cloth or water to clean the unit. 2. Installation Procedures Step 1. Download and read the entire online manual to become familiar with the TNP461 and for detailed installation. Step 2. Cut an opening into the table’s surface. Re fer to the Altinex website at www.altinex.com for table cutout requirements. Note: The table can be 2.25” or less in thickness. Always confirm dimensions before cutting to insure that specifications have n ot changed. Step 3. Insert the TNP461 into the cutout. Under th e table, place the support brackets into the grooves on the side of the unit at the des ired height and secure using the knurled thumb screws. Tighten wing nuts to set screws in place. See Diagram 3 of online manual for details. To lower th e unit, push on the top cover until it locks into place. Step 4. Secure cables to the underside of the table using the hardware provided. Secure the power cord to the table separate from the signa l cables. Leave enough slack in the power cord service loop to allow for easy op ening and closing, but not too much as to cause excess drooping of the service loo p. Adjust loop for best opening and closing of unit. Step 5. Connect your cables to their corresponding input connectors on the bottom of the unit. Raise the unit into position, push down on the front of the top cover; the latching mechanism will then release, allowing the spring to raise it into position. Step 6. To lower the unit, push on the top of the T ilt ‘N Plug Jr. until it locks into place. 3. Limited Warranty/Return policies Please see the Altinex website at http://www.altinex.com for details on warranty and return policies.
Tilt ‘N Plug Jr. User’s Guide 400-0623-001 2 4. Technical Specifications Specifications are subject to change. See www.altinex.com for up-to-date information. Features/Description TNP461 Description General Audio/Video/Communication 6 ft. (2m) Video, VGA 15-pin HD F-M (1) Video, HDMI* HDMI F-M (1) Computer Audio 3.5mm F-M (1) CAT-6 Network RJ-45 F-M (1) USB USB Type A F-M (1) Pass-Through AC Power 1.5 ft. (0.46 m) AC Power User Side Supply Side Universal Receptacle IEC 60320 C14 (male) Accessories Included Hardware -Mounting screws/brackets -Cable clamps/screws Table 1. TNP461 General Mechanical TNP461 Description Max. Table Thickness 2.25 in (57 mm) Width 5.7 in (145 mm) Height, opened (above table) 2.5 in (64 mm) Height, below table 3.9 in (99 mm) Depth 5.2 in (132 mm) Finish Matte Black Net Weight (approx.) 3.2 lb (1.5 kg) Shipping Weight 3.7 lb (1.7 kg) T ° Operating 10 °C-35 °C T ° Maximum 40 °C Humidity 90% non-condensing Table 2. TNP 461 Mechanical Electrical TNP461 Description Power Rating (pass-through AC Power) 220-240VAC, 50/60Hz, 5 A maximum Table 3. TNP 461 Electrical * HDMI, the HDMI Logo, and High-Definition Multime dia Interface are trademarks or registered trademarks of HDMI Licensing LLC in the United States and other countr ies.
Tilt ‘N Plug Jr. User’s Guide 400-0623-001 3 5. About Your Tilt ‘N Plug Jr. · Semi-compact enclosure · Mounts into tabletop · Offers single input plate · Opens/closes by pressing on top cover · India compatible power connectors · All signals pass through to the underside of the t able The TNP461 belongs to the family of International T ilt ‘N Plug Jr. series. It is a compact interconnection solution designed for installation into a table as part of a presentation system. The TNP461 is designed for mounting into a table, podium, or other furniture to provide a way of connecting audiovisual equipment o n top of the furniture to a presentation system below the furniture. The core element of the TNP461 is a multimedia inpu t plate that can be tilted open when needed and pushed closed when not needed. The TNP461 is an international model with power con nectors designed for India. The TNP461 has a universal power receptacle for the user input and is connected to a supply side cable terminated in an IEC60320 C14 connector, with 1.5 f t. cable length. The TNP461 is a pre-configured, compact hybrid inte rconnect solution that includes audio, network, USB and video (VGA and HDMI) ports. All signals pass through the input plate dir ectly to cables on the underside of the table with no intervening circuitry. The use of additional Altinex Signal Management Solutions such as computer video interfaces, distribution amplifiers, and switchers may be desirable. The input plate of the Tilt ‘N Plug Jr. is accessib le by pushing down on the top cover. The unit then auto tilts open with help from an internal pneumatic spring. Once open, the input pla te remains securely in place. The input plate is hidden by pressing down on the top cover until the latching mechanism engages. In its closed position, the top panel lies flush with the table’s top, held in place by the latching mechanism. All Tilt ‘N Plug Jr. Signal Management Solutions co me with a standard top and bezel offering a high qu ality matte black finish. Other finishes or special bezel configurations are availa ble upon request. Please contact an Altinex represe ntative to discuss custom options. TNP461 · RJ-45 F Network (x1) –Snap in port · USB F (x1)-Snap in port · 3.5 mm F Audio (x1) · 15-pin HD F Video(x1) · HDMI F Video (x1) · AC Power (x1)
Tilt ‘N Plug Jr. User’s Guide 400-0623-001 4 6. Application Diagrams Diagram 1: Application Diagram
Tilt ‘N Plug Jr. User’s Guide 400-0623-001 5 Diagram 2: TNP 461 Dimensions
Tilt ‘N Plug Jr. User’s Guide 400-0623-001 6 Diagram 3: TNP461 Mounting
Tilt ‘N Plug Jr. User’s Guide 400-0623-001 7 7. Operation 7.1 Opening and Closing the Tilt N Plug The Tilt ‘N Plug Jr. will open easily when the top is pressed down and then released. When the Tilt ‘N Plug Jr. is not in use, simply pre ss the top down until it is level with the surface of the table and then release. The unit will remain hidden until needed again. 7.2 Power/Signal Connections Connect external devices to the appropriate connect or on the Tilt ‘N Plug Jr. Remember, the devices plugged into the AC power connectors should not draw more than 5A AC. 8. Troubleshooting Guide The Tilt ‘N Plug Jr. supplied was carefully tested and no problems were detected. However, we would li ke to offer the following suggestions: Symptom Resolution Signal quality is poor. Please make sure that the highest quality cables ar e used. The TNP is a passive unit and does not alter signal s in any way. If there is suspected problem with the signal quality, check the quality of the c ables coming into the TNP and connecting to the output of the TNP. If they are of low quality or im properly assembled, this will affect the overall quality of the signal. Damaged power cord Make sure that no cable or power cord is damaged or pinched. If there has been damage, do not use the Tilt N Pl ug. Please call the Altinex Customer Service Department at (714) 990-2300 to have the unit repai red. Unit raises too slowly If the unit does not rise into position correctly, check the service loops for the signal and power cords on the bottom of the unit. If the service loo p is too small, the cables will counteract the spring trying to raise the unit into position. Unit tilts up too fast If the unit rises into position too fast, check the service loops for the signal and power cords on the bottom of the unit. If the service loop is too large and the cables are putting upward pressure on the unit, the unit will tilt up too fast. Unit does not close all the way If the unit does not close flush with the bezel, ch eck the service loops for the signal and power cords on the bottom of the unit. If the service loo p is putting upward pressure in the unit, the unit will not be able to seat all the way down.