Home > Altinex > Audio-visual interconnect box > Altinex TILT N PLUG HIGH QUALITY TABLETOP INTERCONNECT BOX WO GAS SPRING TNP510 User Guide

Altinex TILT N PLUG HIGH QUALITY TABLETOP INTERCONNECT BOX WO GAS SPRING TNP510 User Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Altinex TILT N PLUG HIGH QUALITY TABLETOP INTERCONNECT BOX WO GAS SPRING TNP510 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 18 Altinex manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							TNP51
    TNP51 TNP51
    TNP510/512 
    0/512 0/512 
    0/512 Tilt ‘N Plug
    Tilt ‘N PlugTilt ‘N Plug
    Tilt ‘N Plug
    ®
      
      
     User’s Guide 
      
     
    400-0521-001 
     
             
    1 
    Welcome! 
    We greatly appreciate your purchase of the Tilt ‘N Plug. We are sure you will 
    find it reliable and simple to use. Superior performa nce for the right price, 
    backed by solid technical and customer support is what  ALTINEX has to 
    offer.  
    We are committed to providing our customers with  
    Signal Management Solutions
    ® to the most demanding audiovisual 
    installations at very competitive pricing and we welc ome you to join the 
    ranks of our many satisfied customers throughout the wo rld. 
    1. Precautions and Safety Warnings 
    Please read this manual carefully before using your TNP510/TNP512 
    Interconnect. Keep this manual handy for future refe rence. These safety 
    instructions are to ensure the long life of your TNP5 10/TNP512 and to 
    prevent fire and shock hazards. Please read them care fully and heed all 
    warnings. 
    1.1 General  ·  
    Qualified ALTINEX service personnel or their authoriz ed 
    representatives must perform all service. 
    1.2 Installation Precautions  ·  
    For best results, place the TNP510/TNP512 Interconnect  Box in a dry 
    area away from dust. 
    ·  To prevent fire or shock, do not expose this unit to w ater or moisture. 
    Do not place it in direct sunlight, near heaters or h eat-radiating 
    appliances, or near any liquid. Exposure to direct  sunlight, smoke, or 
    steam can harm internal components. 
    ·  Handle the unit carefully. Dropping or jarring can  damage the bezel. 
    · Never place fingers inside the opening on either side  of the unit. This 
    action could cause injury due to sharp edges inside. 
    ·  Do not place heavy objects on top of the TNP510/TNP5 12. Do not use 
    excessive force to push down on the top of the unit. 
    ·  Disconnect the 
      
     power cord to turn off the main power. This supplie
    s 
    power to the power socket on the pop-up panel. The p ower outlet 
    should be installed near the equipment and should be e asily accessible. 
    · We recommend using wall outlets with a Ground Fault C ircuit 
    Interrupter (GFCI) for maximum protection. 
    ·  Install all cables according to the instructions foun d herein. Do not 
    force or pull out any cable or power cord attached  to the unit. 
    1.3 Cleaning  · 
    Surfaces should be cleaned with a dry cloth. Never u se strong 
    detergents or solvents such as alcohol or thinner. Do  not use a wet cloth 
    or water to clean the unit. 
    1.4 FCC Notice ·  
    This device complies with Part 15 of the FCC Rules. O peration is 
    subject to the following two conditions: (1) This devi ce may not cause 
    harmful interference, and (2) this device must accep t any interference 
    received, including interference that may cause unde sired operation. 
    · This equipment has been tested and found to comply wit h the limits for 
    a Class A digital device, pursuant to Part 15 of the  FCC Rules. These 
    limits are designed to provide reasonable protection a gainst harmful 
    interference when the equipment is operated in a co mmercial 
    environment. This equipment generates, uses, and can ra diate radio 
    frequency energy and, if not installed and used in ac cordance with the 
    instructions found herein, may cause harmful interfe rence to radio 
    communications. Operation of this equipment in a re sidential area is 
    likely to cause harmful interference in which case t he user will be 
    required to correct the interference at his expense. 
    ·  Any changes or modifications to the unit not expressly  approved by 
    ALTINEX, Inc. could void the user’s authority to op erate the 
    equipment. 
     
     2. Installation Procedures 
    Step 1.  Cut an opening into the table’s surface. Ref er to the ALTINEX website at www.altinex.com for table cutout requirements. 
      Note: The table can be 2.50 in (64 mm) or less in t hickness. Always confirm dimensions before cutting to insure that specifications have not changed.  
    Step 2.  Insert the TNP510/TNP512 into the table cuto ut.  
    Step 3.  Place the support brackets under the table a nd place them between the support mount grooves on t he side of the unit. Attach the brackets to the 
    groove at the desired height and secure them to the  bottom of the table using the thumb screws provided. S ee Diagram 5 for details. 
    Step 4.  To lower the unit, push on the top cover unt il it locks into place. 
    If Custom Plates are Installed
     
    Step 5.  Secure all cables to the underside of the tab le using the cable clamps and screws included with the  TNP510/TNP512. Pass the power cord from the 
    bottom of the housing and attach it to the table sep arate from the signal cables. 
      Leave enough slack in the service loop to allow for  easy opening and closing, but not too much as to cause excess drooping of the service loop. 
    Step 
     6.  Connect the appropriate cables with the correct i nput connectors on the bottom of the unit.  
    Step 7.  Once you have applied power and connected t he proper cables on the bottom of the unit you may raise the unit. To raise the unit into position, push 
    down on the front of the top cover; the latching me chanism will then release, allowing the pneumatic spri ng to raise it into position. 
    NOTE:  It may be necessary to adjust the service loop o f the cables for optimal performance. 
     
    3. Limited Warranty/Return policies 
    Please see the ALTINEX website at www.altinex.com for details on warranty and return policies.   
    						
    							Tilt ‘N Plug
    Tilt ‘N Plug Tilt ‘N Plug
    Tilt ‘N Plug 
      
     User’s Guide 
      
     
    400-0521-001 
     
             
    2 
    4. Technical Specifications 
    Specifications are subject to change. See www.altinex.com for up-to-date information. 
     
    Features/Description  TNP510 
    Pass-Through   
      Sectional Plate Slots  6 
    Compatibility*  
      AC Power (U.S.)  SP2102US, SP2107US 
      AC Power (International) DS901-141, SP2201UK, SP2401AU, SP2301CE, and SP2501SA 
      Audio, Video,  
      and Control  SP1500SC, SP3201AV, 
    SP3202AV,SP3203AV, SP3204AV, 
    SP3205AV, SP3206AV, SP3207AV,  SP3208AV, and SP3209AV 
      Blank Slot Covers  SP1001BL, SP1002BL, SP1003BL, 
    SP1004BL, SP1005BL, and  SP1006BL 
      Customizable  SP3212AV, SP3102EP, SP3103EP, 
    SP3104EP, SP3211NT, SP3408CR,  SP3402AD, and SP3403AD 
    Accessories Included   
      Miscellaneous  Mounting hardware 
    Table 1A. TNP510 Description 
    Features/Description  TNP512 
    Pass-Through   
    AC Power 10 ft (3 m) 
      110 VAC  NEMA F-M (2 F to 1 M) 
    Audio/video  6 ft (2 m) 
      Computer Video  15-pin HD F-M (1) 
      Network  RJ-45 F-M (1) 
      Modem  RJ-11 F-M (1) 
      S-Video  4-pin Mini DIN F-M (1) 
      Composite Video  Yellow RCA F-F (1) 
      Control DB-9 F-M (1) 
      Audio, Stereo  3.5 mm F-M (1) 
      Audio Left Channel  Red RCA F-F (1) 
      Audio Right Channel  Black RCA F-F (1) 
    Compatibility   
      Tilt ‘N Plugs  TNP510 
    Accessories Included   
      Miscellaneous  Mounting hardware 
    Table 1B. TNP512 Description  Mechanical  TNP510/TNP512 
    Max. Table Thickness    2.5 in  (64 mm) 
    Min. Table Thickness    0.5 in  (13 mm) 
    Height, opened    7.5 in  (191 mm) 
    Height (above table surface)    3.3 in   (83 mm) 
    Height (below table surface)    4.2 in   (107 mm) 
    Width    7.9 in   (200 mm) 
    Depth    6.5 in   (166 mm) 
    Finish 
    Matte Black 
    T° Operating  (T ° Max)  10 °C-35 °C  (40 °C) 
    Humidity 
    90% non-condensing 
    Table 2. TNP510/TNP512 Mechanical 
    Electrical  
      (Single outlet panel)  TNP510/TNP512 
    Pass-Through Signals 
    All standard audio, video, network, 
    and modem signals are acceptable. 
    Pass-Through AC power  
      (Power Rating )  600W maximum 
    Table 3. TNP510/TNP512 Electrical 
        
    *  Visit the ALTINEX website at www.altinex.com for a complete listing and description of available 
    plates, slot requirements, and connector options.   
    						
    							Tilt ‘N Plug
    Tilt ‘N Plug Tilt ‘N Plug
    Tilt ‘N Plug 
      
     User’s Guide 
      
     
    400-0521-001 
     
             
    3 
      
    5. About Your Tilt ‘N Plug 
    ·
       New leaf-spring replaces gas shock ·   Standard high-quality matte black finish 
    ·   Pop-up dampening for smooth operation ·   Custom finishes available (contact ALTINEX for opt ions and pricing) 
    ·   Simple, drop-in installation ·   International power configurations available 
    The TNP510 and TNP512 are compact interconnect solut ions designed for mounting into tables, podiums, or other furniture as part of a presentation system. 
    Inputs are accessed by pushing down on the top cover a llowing the units to tilt open. The inputs are hidden by pressing down on the top cover until the 
    latching mechanism engages. In the closed positions, the  top covers lie flush with the tabletop. 
    Signals are passed through the TNP510 and TNP512 sectio nal plates to the underside of the table via cables with mating connectors on the opposite end. For 
    example, an RJ-45 F input connector is terminated in  an RJ-45 M connector at the end of a 6 ft (2 m) cable.  The TNP510 is empty, but provides slots for 6 
    single-slot sectional plates that can be configured wi th various multimedia and power inputs. Many section al plates are available for the TNP510 and ordered 
    separately.  See our website for all options.  
    The TNP512 is a package that covers the basic needs o f many Tilt ‘N Plug users. This unit ships as a completely assembled product made up of one TNP510 and 
    one SP3500SC Sectional Plate. The SP3500SC is engrav ed, ready to go, and includes the following: 2 standard U.S. power receptacles, computer video 
    (15-pin HD), COM Port/RS-232 (9-pin D), video (RCA) , S-Video (4-pin mini DIN), audio (2-RCAs), computer audio (3.5 mm), modem (RJ-11), and network 
    (RJ-45) input connectors. All connectors have 6 ft (2  m) cables attached that feed through to the bottom of the unit. 
        
    TILT UP LID
    BEZEL
    INTERFACE AREA
    CUSTOMIZABLE
    EMPTY/SPRING LATCH
    SUPPORT BRACKET LEAF SPRINGS
    DAMPENER
     
    S-VIDEO
    RJ-11 F
    COMPUTER VIDEO
    110V,5A
    DB-9 F
    RJ-45 F
    RCA F (2)
    RCA F
    AC POWER
    COMPOSITE VIDEO
    AUDIO
    110V    60Hz 5A!~
    Audio
    Computer
    ControlV ideo
    S. Video L. Audio
    Telephone R. Audio
    Network
    NETWORK
    CONTROL
    TELEPHONE/MODEM
    15-PIN HD F
    4-PIN Mini DIN F
    3.5 mm F
    STEREO AUDIO
    TILT UP LID
    DAMPENER LEAF SPRINGS
    BEZEL
    SUPPORT BRACKET AND SPRING LATCH                                                                                                                         
    						
    							Tilt ‘N Plug
    Tilt ‘N Plug Tilt ‘N Plug
    Tilt ‘N Plug 
      
     User’s Guide 
      
     
    400-0521-001 
     
             
    4 
    6. Application Diagrams  
    Diagram 1: Typical Setup 
       
       
    						
    							Tilt ‘N Plug
    Tilt ‘N Plug Tilt ‘N Plug
    Tilt ‘N Plug 
      
     User’s Guide 
      
     
    400-0521-001 
     
             
    5 
    Diagram 2: Front Dimensions 
       
    7.5
     [191 mm]
    0.25 [6 mm]
       
    						
    							Tilt ‘N Plug
    Tilt ‘N Plug Tilt ‘N Plug
    Tilt ‘N Plug 
      
     User’s Guide 
      
     
    400-0521-001 
     
             
    6 
    Diagram 3: Side Dimensions 
       
    INTERFACE3.3
     [83 mm]
    4.2
     [107 mm]
    5.9
     [150 mm]
    OPERATOR
       
    						
    							Tilt ‘N Plug
    Tilt ‘N Plug Tilt ‘N Plug
    Tilt ‘N Plug 
      
     User’s Guide 
      
     
    400-0521-001 
     
             
    7 
    Diagram 4: Top Dimensions 
       
    6.5
     [166 mm]
    7.9 
     [200 mm]
       
    						
    							Tilt ‘N Plug
    Tilt ‘N Plug Tilt ‘N Plug
    Tilt ‘N Plug 
      
     User’s Guide 
      
     
    400-0521-001 
     
             
    8 
    Diagram 5: Mounting Sample 
       
    OPERATOR
    BRACKETS (2)SUPPORT
    THUMBSCREWS (2)
    TABLETOP
    INTERFACE
       
    						
    							Tilt ‘N Plug
    Tilt ‘N Plug Tilt ‘N Plug
    Tilt ‘N Plug 
      
     User’s Guide 
      
     
    400-0521-001 
     
             
    9 
    Diagram 6: Popular Section Plates 
       
       
     
      
       
     
     
    Many  different  plates  can  be  installed  on  the  TNP510  using  up  to  6  slots  total.  In  addition  to  standard  plates,  custom  plates  can  be  made 
    using blank plates available. For a complete listing and detailed descriptions, see the ALTINEX web site at www.altinex.com. 
       
    STANDARD PLATES 
    6 SLOTS 3 SLOT PLATES 
    2 SLOT PLATES 
    1 SLOT PLATES                
    						
    							Tilt ‘N Plug
    Tilt ‘N Plug Tilt ‘N Plug
    Tilt ‘N Plug 
      
     User’s Guide 
      
     
    400-0521-001 
     
             
    10 
    7. Operation  
    7.1 Opening and Closing the TNP 
    The TNP510/TNP512 will open easily when the top is pressed down and 
    then released.  
    When the TNP510/TNP512 is not in use, simply press the  top down until it 
    is level with the surface of the table and then relea se.  The unit will remain 
    hidden until needed again.  
    7.2 Power/Signal Connections 
    Connect external devices to the appropriate connect or on the 
    TNP510/TNP512.  Remember, the devices plugged into  the AC power 
    connectors should not draw more than 600W of power.   
    8. Troubleshooting Guide 
    The TNP510/TNP512 supplied was carefully tested and n o problems were 
    detected. However, we would like to offer the follo wing suggestions: 
    · Please make sure that the highest quality network cabl es are used.  
    · Make sure that no cable or power cord is damaged or p inched. If 
    there has been damage, do not use the TNP510/TNP512.  Please call 
    the ALTINEX Customer Service Department at (714) 990 -2300 to 
    have the unit repaired.  
    ·  If the unit does not rise into position correctly, ch eck the service 
    loops for the signal and power cords on the bottom of  the unit.  
       
    						
    All Altinex manuals Comments (0)

    Related Manuals for Altinex TILT N PLUG HIGH QUALITY TABLETOP INTERCONNECT BOX WO GAS SPRING TNP510 User Guide