Have a look at the manual Altinex TILT N PLUG CONFIGURABLE TABLETOP INTERCONNECT BOX TNP601 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 18 Altinex manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
TNP600 TNP600 TNP600 TNP600/ // / C CC Customizable ustomizableustomizable ustomizable T T T Tilt iltilt ilt ‘N P ‘N P ‘N P ‘N Plug luglug lug® ®® ® User’s Guide 400-0493-002 1 Welcome! We greatly appreciate your purchase of the TNP600 Customizable TILT ‘N PLUG®. W e are sure you will find it reliable and simple to us e. Superior performance for the right price, backed by solid technical and customer support is what ALTINEX has to offer. We are committed to providing our customers with Signal Management Solutions ® to the most demanding audiovisual installations at very competitive pricing and we welc ome you to join the ranks of our many satisfied customers throughout the wo rld. 1. Precautions and Safety Warnings Please read this manual carefully before using your TNP600. Keep this manual handy for future reference. These safety instru ctions are to ensure the long life of your TNP600 and to prevent fire an d shock hazards. Please read them carefully and heed all warnings. 1.1 General · Unauthorized personnel shall not open the unit, as ther e are high-voltage components inside. · Qualified ALTINEX service personnel or their authoriz ed representatives must perform all service. 1.2 Installation Precautions · For best results, place the TNP600 in a dry area away from dust. · To prevent fire or shock, do not expose this unit to w ater or moisture. Do not place the TNP600 in direct sunlight, near he aters or heat radiating appliances, or near any liquid. Exposure t o direct sunlight, smoke, or steam can harm internal components. · Handle the TNP600 carefully. Dropping or jarring ca n damage the bezel. · Never place fingers inside the opening on either side of the unit. This action could cause injury due to sharp edges inside. · Do not place heavy objects on top of the TNP600. Do not use excessive force to push down on the top of the unit. · Disconnect the TNP600’s power cord to turn off the m ain power. This supplies power to the power socket on the pop up panel . The power outlet should be installed near the equipment and be easily accessible. · We recommend using wall outlets with a Ground Fault C ircuit Interrupter (GFCI) for maximum protection. · Install all cables according to the instructions foun d herein. Do not force or pull out any cable or power cord attached to the TNP600. 1.3 Cleaning · Surfaces should be cleaned with a dry cloth. Never u se strong detergents or solvents such as alcohol or thinner. Do not use a wet cloth or water to clean the unit. 1.4 FCC Notice · This device complies with Part 15 of the FCC Rules. O peration is subject to the following two conditions: (1) This devi ce may not cause harmful interference, and (2) this device must accep t any interference received, including interference that may cause unde sired operation. · This equipment has been tested and found to comply wit h the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection a gainst harmful interference when the equipment is operated in a co mmercial environment. This equipment generates, uses, and can ra diate radio frequency energy and, if not installed and used in ac cordance with the instructions found herein, may cause harmful interfe rence to radio communications. Operation of this equipment in a re sidential area is likely to cause harmful interference in which case t he user will be required to correct the interference at his expense. · Any changes or modifications to the unit not expressly approved by ALTINEX, Inc. could void the user’s authority to op erate the equipment. 2. Installation Procedures Step 1. Cut an opening into the table’s surface. Ref er to the ALTINEX website at www.altinex.com for tab le cutout requirements. Note: The table can be 2.50” or less in thickness. Al ways confirm dimensions before cutting to insure that specifications have not changed. Step 2. Insert the TNP600 into the table cutout. Step 3. Place the support brackets under the table a nd place them between the support mount grooves on t he side of the TNP600. Attach the brackets to the groove at the desired height and secure them to the bottom of the table using the thumbscrews provided. Step 4. To lower the unit, push on the top of the TN P600 until it locks into place. Note: A standard, empty, TNP600 does not latch in the down position. A cable support bracket is required. The exact cable support bracket required is determined at the time of customization. If Custom Plates Are Installed Step 5. Secure all cables to the underside of the tab le using the cable clamps and screws included with the TNP600. Pass the power cord from the bottom of the housing and attach it to the table separate from the signal cables. Leave enough slack in the service loop to allow for easy opening and closing, but not too much as to cause excess drooping of the service loop. Step 6. Connect the appropriate cables with the corr ect input connectors on the bottom of the unit. Step 7. Once you have applied power and connected t he proper cables on the bottom of the unit you may raise the unit. To raise the TNP600 into position, push down on the front of the top cover; the latchin g mechanism will then release, allowing the pneumatic spring to raise it into position. Note: It may be necessary to adjust the service loop o f the cables for optimal performance. 3. Limited Warranty/Return policies Please see the ALTINEX website at www.altinex.com for details on warranty and return policies.
TNP600 TNP600 TNP600 TNP600 User’s Guide 400-0493-002 2 4. Technical Specifications Specifications are subject to change. See www.altinex.com for up-to-date information. Features/ Description TNP600 Inputs Customizable Custom Audio/Video/Control Outputs Customizable Custom Audio/Video/Control Power Customizable US or International Table 1. TNP600 General MECHANICAL TNP600 Max. Table Thickness 2.5 in (64 mm) Height, opened 7.3 in (184 mm) Height (above table) 3.2 in (82 mm) Height (below table) 4.0 in (102 mm) Width 10.0 in (253 mm) Depth 6.5 in (166 mm) Finish Matte Black T° Operating (T ° Max) 10 °C-35 °C (40 °C) Humidity 90% non-condensing Table 2. TNP600 Mechanical Electrical (Single outlet panel) TNP600 Pass-Through Signals All standard audio, video, network, and modem signals are acceptable. Power Rating (pass-through AC power) 600W maximum Table 3. TNP600 Electrical
TNP600 TNP600 TNP600 TNP600 User’s Guide 400-0493-002 3 5. About Your TNP600 The TNP600 is a compact interconnection solution designed for installation into a table as part of a presentation system. It is designed for mounting into a table , podium, or other furniture to provide a way of conn ecting audiovisual equipment on top of the furniture to a presentation system below the furniture. The TNP600 is empty, but can be configured with vari ous multimedia and power input plates that can be accessed when the TNP600 is tilted open. The input plates of the TNP600 are accessible by pushing down on the top cover. The unit then auto tilts open with help from an internal pneumatic spring. Once open, the input plate remains securely in place. The input pla te is hidden by pressing down on the top cover until the latching mechanism engages. In its closed position, the top panel lies flush with the tabletop until nee ded again. All Tilt ‘N Plug Signal Management Solutions come wi th a standard top and bezel offering a high quality matte black finish. Other finishes or special bezel configurations are available upon request. Please con tact an ALTINEX representative to discuss custom option s. TILT UP LID BEZEL CUSTOMIZABLE INTERFACE AREA EMPTY/ WITH GAS SPRING/LATCH MOUNTING BRACKET SUPPORT/
TNP600 TNP600 TNP600 TNP600 User’s Guide 400-0493-002 4 6. Application Diagrams Diagram 1: Front Dimensions 7.3 [184mm]
TNP600 TNP600 TNP600 TNP600 User’s Guide 400-0493-002 5 Diagram 2: Side Dimensions 3.2 [82mm] 4.0 [102mm]
TNP600 TNP600 TNP600 TNP600 User’s Guide 400-0493-002 6 Diagram 3: Top Dimensions 6.5 [166mm] 10.0 [253mm]
TNP600 TNP600 TNP600 TNP600 User’s Guide 400-0493-002 7 Diagram 4: Mounting Sample TABLETOP SUPPORT THUMBSCREW BRACKET THUMBSCREW BRACKET SUPPORT
TNP600 TNP600 TNP600 TNP600 User’s Guide 400-0493-002 8 7. Operation 7.1 Opening and Closing the TNP600 The TNP600 will open easily when the top is pressed down and then released. When the TNP600 is not in use, simply press the top down until it is level with the surface of the table and then release. The unit will remain hidden until needed again. 7.2 Power/Signal Connections Connect external devices to the appropriate connect or on the TNP600. Remember, the devices plugged into the AC power conn ectors should not draw more than 600W of power. 8. Troubleshooting Guide The TNP600 supplied was carefully tested and no proble ms were detected. However, we would like to offer the following suggest ions: · Please make sure that the highest quality network cabl es are used. · Make sure that no cable or power cord is damaged or p inched. If there has been damage, do not use the TNP600. Please call the ALTINEX Customer Service Department at (714) 990-230 0 to have the unit repaired. · If the unit does not rise into position correctly, ch eck the service loops for the signal and power cords on the bottom of the unit