    Have a look at the manual Altinex TILT N PLUG CONFIGURABLE TABLETOP INTERCONNECT BOX TNP601 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 18 Altinex manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							TNP600
    TNP600 TNP600
    TNP600/
    //
    / C
    CC
    Customizable
    ustomizableustomizable
    ustomizable T
     T T
     Tilt
    iltilt
    ilt ‘N P
     ‘N P ‘N P
     ‘N Plug
    luglug
    lug®
    ®®
    ® 
      
     User’s Guide 
      
     
    400-0493-002 
     
             
    1 
    Welcome! 
    We greatly appreciate your purchase of the TNP600 Customizable 
    TILT ‘N PLUG®. W e are sure you will find it reliable and simple to us e. 
    Superior performance for the right price, backed by  solid technical and 
    customer support is what ALTINEX has to offer.  
    We are committed to providing our customers with  
    Signal Management Solutions
    ® to the most demanding audiovisual 
    installations at very competitive pricing and we welc ome you to join the 
    ranks of our many satisfied customers throughout the wo rld. 
    1. Precautions and Safety Warnings 
    Please read this manual carefully before using your TNP600. Keep this 
    manual handy for future reference. These safety instru ctions are to ensure 
    the long life of your TNP600 and to prevent fire an d shock hazards. Please 
    read them carefully and heed all warnings. 
    1.1 General  ·  
    Unauthorized personnel shall not open the unit, as ther e are 
    high-voltage components inside. 
    ·  Qualified ALTINEX service personnel or their authoriz ed 
    representatives must perform all service. 
    1.2 Installation Precautions  ·  
    For best results, place the TNP600 in a dry area away  from dust. 
    · To prevent fire or shock, do not expose this unit to w ater or moisture. 
    Do not place the TNP600 in direct sunlight, near he aters or heat 
    radiating appliances, or near any liquid. Exposure t o direct sunlight, 
    smoke, or steam can harm internal components. 
    ·  Handle the TNP600 carefully. Dropping or jarring ca n damage the 
    bezel. 
    ·  Never place fingers inside the opening on either side  of the unit. This 
    action could cause injury due to sharp edges inside. 
    ·  Do not place heavy objects on top of the TNP600. Do  not use excessive 
    force to push down on the top of the unit. 
    ·  Disconnect the TNP600’s power cord to turn off the m ain power. This 
    supplies power to the power socket on the pop up panel . The power 
    outlet should be installed near the equipment and be  easily accessible. 
    · We recommend using wall outlets with a Ground Fault C ircuit 
    Interrupter (GFCI) for maximum protection. 
    ·  Install all cables according to the instructions foun d herein. Do not 
    force or pull out any cable or power cord attached  to the TNP600.  
    1.3 Cleaning  · 
    Surfaces should be cleaned with a dry cloth. Never u se strong 
    detergents or solvents such as alcohol or thinner. Do  not use a wet cloth 
    or water to clean the unit. 
    1.4 FCC Notice ·  
    This device complies with Part 15 of the FCC Rules. O peration is 
    subject to the following two conditions: (1) This devi ce may not cause 
    harmful interference, and (2) this device must accep t any interference 
    received, including interference that may cause unde sired operation. 
    · This equipment has been tested and found to comply wit h the limits for 
    a Class A digital device, pursuant to Part 15 of the  FCC Rules. These 
    limits are designed to provide reasonable protection a gainst harmful 
    interference when the equipment is operated in a co mmercial 
    environment. This equipment generates, uses, and can ra diate radio 
    frequency energy and, if not installed and used in ac cordance with the 
    instructions found herein, may cause harmful interfe rence to radio 
    communications. Operation of this equipment in a re sidential area is 
    likely to cause harmful interference in which case t he user will be 
    required to correct the interference at his expense. 
    ·  Any changes or modifications to the unit not expressly  approved by 
    ALTINEX, Inc. could void the user’s authority to op erate the 
    equipment. 
    2. Installation Procedures 
    Step 1.  Cut an opening into the table’s surface. Ref er to the ALTINEX website at www.altinex.com for tab le cutout requirements. 
      Note: The table can be 2.50” or less in thickness. Al ways confirm dimensions before cutting to insure that specifications have not changed.
     
    Step 2.  Insert the TNP600 into the table cutout.  
    Step 3.  Place the support brackets under the table a nd place them between the support mount grooves on t he side of the TNP600. Attach the brackets to the 
    groove at the desired height and secure them to the  bottom of the table using the thumbscrews provided. 
    Step 4.  To lower the unit, push on the top of the TN P600 until it locks into place. 
    Note:  A standard, empty, TNP600 does not latch in the  down position. A cable support bracket is required. The exact cable support bracket required 
    is determined at the time of customization.  
    If Custom Plates Are Installed
     
    Step 5.  Secure all cables to the underside of the tab le using the cable clamps and screws included with the  TNP600. Pass the power cord from the bottom of 
    the housing and attach it to the table separate from  the signal cables. 
      Leave enough slack in the service loop to allow for  easy opening and closing, but not too much as to cause excess drooping of the service loop. 
    Step 6.  Connect the appropriate cables with the corr ect input connectors on the bottom of the unit. 
    Step 7.  Once you have applied power and connected t he proper cables on the bottom of the unit you may raise the unit. To raise the TNP600 into position, 
    push down on the front of the top cover; the latchin g mechanism will then release, allowing the pneumatic  spring to raise it into position. 
    Note:  It may be necessary to adjust the service loop o f the cables for optimal performance. 
    3. Limited Warranty/Return policies 
    Please see the ALTINEX website at www.altinex.com for  details on warranty and return policies.   
    						
    							TNP600
    TNP600 TNP600
    TNP600 
      
     User’s Guide 
      
     
    400-0493-002 
     
             
    2 
    4. Technical Specifications 
    Specifications are subject to change. See www.altinex.com for up-to-date information. 
     
    Features/  
    Description  TNP600 
    Inputs 
     
       Customizable Custom 
    Audio/Video/Control 
    Outputs   
       Customizable Custom 
    Audio/Video/Control 
    Power   
       Customizable  US or International 
    Table 1. TNP600 General   
    MECHANICAL  TNP600 
    Max. Table Thickness    2.5 in  (64 mm) 
    Height, opened    7.3 in   (184 mm) 
    Height (above table)    3.2 in   (82 mm) 
    Height (below table)    4.0 in   (102 mm) 
    Width    10.0 in   (253 mm) 
    Depth    6.5 in   (166 mm) 
    Finish  Matte Black 
    T° Operating  (T ° Max)  10 °C-35 °C  (40 °C) 
    Humidity 
    90% non-condensing 
    Table 2. TNP600  Mechanical    Electrical  
    (Single outlet panel) 
    TNP600 
    Pass-Through Signals 
    All standard audio, video, network,  
    and modem signals are acceptable. 
    Power Rating  
    (pass-through AC power)  600W maximum 
    Table 3. TNP600 Electrical         
    						
    							TNP600
    TNP600 TNP600
    TNP600 
      
     User’s Guide 
      
     
    400-0493-002 
     
             
    3 
    5. About Your TNP600 
    The TNP600 is a compact interconnection solution designed for installation into a table as part of a presentation system. It is designed for mounting into a table , 
    podium, or other furniture to provide a way of conn ecting audiovisual equipment on top of the furniture  to a presentation system below the furniture. 
    The TNP600 is empty, but can be configured with vari ous multimedia and power input plates that can be accessed when the TNP600 is tilted open. The input 
    plates of the TNP600 are accessible by pushing down on  the top cover. The unit then auto tilts open with help from an internal pneumatic spring. Once open, the  
    input plate remains securely in place. The input pla te is hidden by pressing down on the top cover until  the latching mechanism engages. In its closed position,  
    the top panel lies flush with the tabletop until nee ded again. 
    All Tilt ‘N Plug Signal Management Solutions come wi th a standard top and bezel offering a high quality matte black finish. Other finishes or special bezel 
    configurations are available upon request. Please con tact an ALTINEX representative to discuss custom option s. 
    TILT UP LID
    BEZEL
    CUSTOMIZABLE
    INTERFACE AREA
    EMPTY/
    WITH GAS SPRING/LATCH
    MOUNTING BRACKET
    SUPPORT/    
    						
    							TNP600
    TNP600 TNP600
    TNP600 
      
     User’s Guide 
      
     
    400-0493-002 
     
             
    4 
    6. Application Diagrams  
    Diagram 1: Front Dimensions 
       
    7.3
     [184mm]
       
    						
    							TNP600
    TNP600 TNP600
    TNP600 
      
     User’s Guide 
      
     
    400-0493-002 
     
             
    5 
    Diagram 2: Side Dimensions 
       
    3.2
     [82mm]
    4.0
     [102mm]
       
    						
    							TNP600
    TNP600 TNP600
    TNP600 
      
     User’s Guide 
      
     
    400-0493-002 
     
             
    6 
    Diagram 3: Top Dimensions 
       
    6.5
     [166mm]
    10.0
     [253mm]
       
    						
    							TNP600
    TNP600 TNP600
    TNP600 
      
     User’s Guide 
      
     
    400-0493-002 
     
             
    7 
    Diagram 4: Mounting Sample 
       
    TABLETOP
    SUPPORT
    THUMBSCREW BRACKET
    THUMBSCREW
    BRACKET
    SUPPORT
       
    						
    							TNP600
    TNP600 TNP600
    TNP600 
      
     User’s Guide 
      
     
    400-0493-002 
     
             
    8 
    7. Operation  
    7.1 Opening and Closing the TNP600 
    The TNP600 will open easily when the top is pressed down and then 
    released.  
    When the TNP600 is not in use, simply press the top down  until it is level 
    with the surface of the table and then release.  The  unit will remain hidden 
    until needed again. 
    7.2 Power/Signal Connections 
    Connect external devices to the appropriate connect or on the TNP600.  
    Remember, the devices plugged into the AC power conn ectors should not 
    draw more than 600W of power.   
    8. Troubleshooting Guide 
    The TNP600 supplied was carefully tested and no proble ms were detected. 
    However, we would like to offer the following suggest ions: 
    · Please make sure that the highest quality network cabl es are used.  
    · Make sure that no cable or power cord is damaged or p inched. If 
    there has been damage, do not use the TNP600. Please  call the 
    ALTINEX Customer Service Department at (714) 990-230 0 to have 
    the unit repaired.  
    ·  If the unit does not rise into position correctly, ch eck the service 
    loops for the signal and power cords on the bottom of  the unit 
         
    						
    All Altinex manuals Comments (0)

    Related Manuals for Altinex TILT N PLUG CONFIGURABLE TABLETOP INTERCONNECT BOX TNP601 User Guide