    Have a look at the manual Altinex TILT N PLUG CONFIGURABLE TABLETOP INTERCONNECT BOX TNP600 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 18 Altinex manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							TNP600/ Customizable Tilt ‘N Plug® User’s Guide 
    400-0493-003  
     
     
     
     
     
     
    1 
     
    Welcome! 
    We greatly appreciate your purchase of the TNP600 Customizable 
    TILT ‘N PLUG®. We are sure you will find it reliable and simple to use. 
    Superior performance for the right price, backed by solid technical and 
    customer support is what ALTINEX has to offer. 
    We are committed to providing our customers with 
    Signal Management Solutions® to the most demanding audiovisual 
    installations at competitive pricing and we welcome you to join the ranks of 
    our many satisfied customers throughout the world. 
    1. Precautions and Safety Warnings 
    Please read this manual carefully before using your TNP600. Keep this 
    manual handy for future reference. These safety instructions are to ensure 
    the long life of your TNP600 and to prevent fire and shock hazards. Please 
    read them carefully and heed all warnings. 
    1.1 General 
     Unauthorized personnel shall not open the unit, as there are 
    high-voltage components inside. 
     Qualified ALTINEX service personnel or their authorized 
    representatives must perform all service. 
    1.2 Installation Precautions 
     For best results, place the TNP600 in a dry area away from dust. 
     To prevent fire or shock, do not expose this unit to water or moisture. 
    Do not place the TNP600 in direct sunlight, near heaters or heat 
    radiating appliances, or near any liquid. Exposure to direct sunlight, 
    smoke, or steam can harm internal components. 
     Handle the TNP600 carefully. Dropping or jarring can damage the 
    bezel. 
     Never place fingers inside the opening on either side of the unit. This 
    action could cause injury due to sharp edges inside. 
     Do not place heavy objects on top of the TNP600. Do not use excessive 
    force to push down on the top of the unit. 
     Disconnect the TNP600’s power cord to turn off the main power. This 
    supplies power to the power socket on the pop up panel. The power 
    outlet should be installed near the equipment and be easily accessible. 
     We recommend using wall outlets with a Ground Fault Circuit 
    Interrupter (GFCI) for maximum protection. 
     Install all cables according to the instructions found herein. Do not 
    force or pull out any cable or power cord attached to the TNP600.  
    1.3 Cleaning 
     Surfaces should be cleaned with a dry cloth. Never use strong 
    detergents or solvents such as alcohol or thinner. Do not use a wet cloth 
    or water to clean the unit. 
    1.4 FCC Notice 
     This device complies with Part 15 of the FCC Rules. Operation is 
    subject to the following two conditions: (1) This device may not cause 
    harmful interference, and (2) this device must accept any interference 
    received, including interference that may cause undesired operation. 
     This equipment has been tested and found to comply with the limits for 
    a Class A digital device, pursuant to Part 15 of the FCC Rules. These 
    limits are designed to provide reasonable protection against harmful 
    interference when the equipment is operated in a commercial 
    environment. This equipment generates, uses, and can radiate radio 
    frequency energy and, if not installed and used in accordance with the 
    instructions found herein, may cause harmful interference to radio 
    communications. Operation of this equipment in a residential area is 
    likely to cause harmful interference in which case the user will be 
    required to correct the interference at his expense. 
     Any changes or modifications to the unit not expressly approved by 
    ALTINEX, Inc. could void the user’s authority to operate the 
    equipment. 
    2. Installation Procedures 
    Step 1. Cut an opening into the table’s surface. Refer to the ALTINEX website at www.altinex.com for table cutout template. 
     Note: The table can be 2.50” or less in thickness. Always confirm dimensions before cutting to insure that specifications have not changed. 
    Step 2. Insert the TNP600 into the table cutout. 
    Step 3. Place the support brackets under the table and place them between the support mount grooves on the side of the TNP600. Attach the brackets to the 
    groove at the desired height and secure them to the bottom of the table using the thumbscrews provided. 
    Step 4. To lower the unit, push on the top of the TNP600 until it locks into place. 
    Note: A standard, empty, TNP600 does not latch in the down position. A cable support bracket is required. The exact cable support bracket required 
    is determined at the time of customization.  
    If Custom Plates Are Installed 
    Step 5. Secure all cables to the underside of the table using the cable clamps and screws included with the TNP600. Pass the power cord from the bottom of 
    the housing and attach it to the table separate from the signal cables. 
     Leave enough slack in the service loop to allow for easy opening and closing, but not too much as to cause excess drooping of the service loop. 
    Step 6. Connect the appropriate cables with the correct input connectors on the bottom of the unit. 
    Step 7. Once you have applied power and connected the proper cables on the bottom of the unit you may raise the unit. To raise the TNP600 into position, 
    push down on the front of the top cover; the latching mechanism will then release, allowing the pneumatic spring to raise it into position. 
    Note: It may be necessary to adjust the service loop of the cables for optimal performance. 
    3. Limited Warranty/Return policies 
    Please see the ALTINEX website at www.altinex.com for details on warranty and return policies.  
    						
    							TNP600 User’s Guide 
    400-0493-003  
     
     
     
     
     
     
    2 
     
    4. Technical Specifications 
    Specifications are subject to change. See www.altinex.com for up-to-date information. 
     
    Features/ Description TNP600 
    Inputs  
       Customizable Custom Audio/Video/Control 
    Outputs  
       Customizable Custom Audio/Video/Control 
    Power  
       Customizable US or International 
    Compatibility 
    DS801-429 
    DS801-431 
    DS801-432 
    Table 1. TNP600 General 
     
    MECHANICAL TNP600 
    Max. T able Thickness  2.5 in (64 mm) 
    Height, opened  7.3 in  (184 mm) 
    Height (above table)  3.2 in  (82 mm) 
    Height (below table)  4.0 in  (102 mm) 
    W idth  10.0 in  (253 mm) 
    Depth  6.5 in  (166 mm) 
    Finish Matte Black 
    T Operating  (T Max) 10C-35C  (40C) 
    Humidity 90 non-condensing 
    Table 2. TNP600  Mechanical  
    Electrical (Single outlet panel) TNP600 
    Pass-Through Signals All standard audio, video, network, and modem signals are acceptable. 
    Power Rating  (pass-through AC power) 600W  maximum 
    Table 3. TNP600 Electrical  
     
      
    						
    							TNP600 User’s Guide 
    400-0493-003  
     
     
     
     
     
     
    3 
     
     
    5. About Your TNP600 
     Compact interconnect Solutions 
     Mounts into existing or new furniture 
     Configurable with multimedia and/or power input plates 
     High-quality matte black finish 
     Fits tables up to 2.5” thick 
    The TNP600 is a compact interconnection solution designed for installation into a table as part of a presentation system. It is designed for mounting into a table, 
    podium, or other furniture to provide a way of connecting audiovisual equipment on top of the furniture to a presentation system below the furniture. 
    The TNP600 is empty, but can be configured with various multimedia and power input plates that can be accessed when the TNP600 is tilted open. The input 
    plates of the TNP600 are accessible by pushing down on the top cover. The unit then auto tilts open with help from an internal pneumatic spring. Once open, the 
    input plate remains securely in place. The input plate is hidden by pressing down on the top cover until the latching mechanism engages. In its closed position, 
    the top panel lies flush with the tabletop until needed again. 
    All Tilt ‘N Plug Signal Management Solutions come with a standard top and bezel offering a high quality matte black finish. Other finishes or special bezel 
    configurations are available upon request. Please contact an ALTINEX representative to discuss custom options. 
     
     TILT UP LID
    BEZEL
    CUSTOMIZABLE
    INTERFACE AREA
    EMPTY/
    WITH GAS SPRING/LATCH
    MOUNTING BRACKET
    SUPPORT/  
    						
    							TNP600 User’s Guide 
    400-0493-003  
     
     
     
     
     
     
    4 
     
    6. Application Diagrams 
     
    TNP600 With Standard Configuration Plate DS801-429 Installed into it  
    						
    							TNP600 User’s Guide 
    400-0493-003  
     
     
     
     
     
     
    5 
     
     
    Diagram 2: Front Dimensions 
     
     
     
     
     
     
          7.3
     [184mm]  
    						
    							TNP600 User’s Guide 
    400-0493-003  
     
     
     
     
     
     
    6 
     
    Diagram 3: Side Dimensions 
     
     
     3.3
     [83mm]
    4.0
     [101mm]  
    						
    							TNP600 User’s Guide 
    400-0493-003  
     
     
     
     
     
     
    7 
     
    Diagram 4: Top Dimensions* 
     
     
    * Not Cutout Dimension  6.5
     [166mm]
    10.0
     [253mm]  
    						
    							TNP600 User’s Guide 
    400-0493-003  
     
     
     
     
     
     
    8 
     
    Diagram 5: Mounting Sample 
     
     
     TABLETOP
    THUMBSCREWTHUMBSCREW
    SUPPORT
    BRACKET
    SUPPORT
    BRACKET  
    						
    							TNP600 User’s Guide 
    400-0493-003  
     
     
     
     
     
     
    9 
     
    7. Operation 
    7.1 Opening and Closing the T NP600 
    The TNP600 will open easily when the top is pressed down and then 
    released. 
    When the TNP600 is not in use, simply press the top down until it is level 
    with the surface of the table and then release.  The unit will remain hidden 
    until needed again. 
    7.2 Power/Signal Connections 
    Connect external devices to the appropriate connector on the TNP600.  
    Remember, the devices plugged into the AC power connectors should not 
    draw more than 600W of power. 
     
    8. Troubleshooting Guide 
    The TNP600 supplied was carefully tested and no problems were detected. 
    However, we would like to offer the following suggestions: 
     Please make sure that the highest quality network cables are used.  
     Make sure that no cable or power cord is damaged or pinched. If 
    there has been damage, do not use the TNP600. Please call the 
    ALTINEX Customer Service Department at (714) 990-2300 to have 
    the unit repaired.  
     If the unit does not rise into position correctly, check the service 
    loops for the signal and power cords on the bottom of the unit 
     
      
    						
    All Altinex manuals Comments (0)