Home > Altinex > Audio-visual interconnect box > Altinex TILT N PLUG 2 X PWR 2 X USB TNP355C User Guide

Altinex TILT N PLUG 2 X PWR 2 X USB TNP355C User Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Altinex TILT N PLUG 2 X PWR 2 X USB TNP355C User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 18 Altinex manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							TNP355C INTERCONNECT BOX User’s Guide 
    400-0615-001 
     
     
     
     
     
    1 
     
    Welcome!
    We greatly appreciate your purchase of your TNP355C Series 
    Tilt N Plug. We are sure you will find it reliable and simple to 
    use. We are committed to providing Signal Management 
    Solutions® to our customers for the most demanding 
    audiovisual installations at competitive pricing and we welcome 
    you to join the ranks of our many satisfied customers 
    throughout the world.  
     
    1. Precautions and Safety Warnings  
    Please read this manual carefully before using your Tilt N 
    Plug. Interconnect Box. Keep this manual handy for future 
    reference. These safety instructions are to ensure the long life 
    of your Tilt N Plug and to prevent fire and shock hazards. 
    Please read them carefully and heed all warnings.  
    1.1 General  
     Unauthorized personnel shall not open the unit as there 
    are high-voltage components inside. Only qualified Altinex 
    service personnel or their authorized representatives must 
    perform all service.  
    1.2 Installation Precautions  
     For best results, place the Tilt N Plug in a dry area away 
    from dust. 
    To prevent fire or shock, do not expose this unit to water 
    or moisture. Do not place the unit in direct sunlight, near 
    heaters or heat-radiating appliances, or near any liquid. 
    Exposure to direct sunlight, smoke, or steam can harm 
    internal components.  
     Handle carefully; dropping or jarring can damage the 
    bezel.  
     Never place fingers inside the opening on either side of 
    the unit. This action could cause injury due to sharp edges 
    inside.  
     Do not place heavy objects on top of the Tilt N Plug. Do 
    not use excessive force to push down on the top of the 
    unit.  
     Disconnect the power cord to turn off the power. This 
    supplies power to the socket on the pop-up panel. The 
    power outlet should be installed near the equipment and 
    be easily accessible.  
     Install all cables according to the instructions found herein. 
    Do not force or pull any cable that is attached to the Tilt N 
    Plug.  
    1.3 Cleaning  
     Surfaces should be cleaned with a dry cloth. Never use 
    strong detergents or solvents such as alcohol or thinner.  
     
    2. Installation Procedures  
    Step 1 Cut an opening into the table’s surface. Refer to the ALTINEX website at 
    http://www.altinex.com/ for table cutout requirements.  
    NOTE: The table can be 2.25 in (57 mm) or less in thickness. Always confirm 
    dimensions before cutting to insure that specifications have not changed. 
    Step 2 Insert the TNP355C into the table cutout.  
    Step 3 Place the support brackets under the table and place them between the support 
    mount grooves on the side of the unit. Attach the brackets to the groove at the 
    desired height and secure them to the bottom of the table using the knurled 
    table securing screws provided with the additional wing nuts for added 
    tightening.  
    Step 4 To lower the unit, push on the top cover until it locks into place.  
    Step 5 Secure power cable to the underside of the table using the cable clamps and screws included with the TNP. Pass the 
    power cord from the bottom of the housing and attach it to the table separate from the signal cables. Leave enough slack 
    in the service loop to allow for easy opening and closing, but not too much as to cause excess drooping of the service 
    loop. 
    Step 6 Once you have applied power on the bottom of the unit you may raise the unit. To raise the unit into position, push down 
    on the front of the top cover; the latching mechanism will then release, allowing the pneumatic spring to raise it into 
    position.  
    NOTE: It may be necessary to adjust the service loop of the cable for optimal performance.  
     
     
    3. Limited Warranty/Return Policies  
    Please see the ALTINEX website at www.altinex.com for details on warranty and return policies.    
    						
    							TNP355C User’s Guide 
    400-0615-001 
     
     
     
     
     
    2 
     
    4. Technical Specification 
    Specifications are subject to change. Please visit http://www.altinex.com for up-to-date specification 
     
    Features/Description  
    TNP355C 
    Pass-Through AC Power          9ft. (3.0 m) 
     125 VAC,60 Hz, 12A NEMA Socket-Plug (2) 
    Internal USB circuit USB 2.0 type A female (2) 
    Agency Approval 
     UL/C-UL Listed File E254082 
    Accessories Included 
    Hardware Mounting screws/brackets 
    Cable clamps/screws 
    Table 1 TNP355 General Specifications 
     
     
    Mechanical  
    Max. Table Thickness 2.25 in (57 mm) 
    Height, opened 5.88 in (149 mm) 
    Width 5.7 in (145 mm) 
    Depth 5.2 in (132 mm) 
    Custom Finish Polished Chrome 
    Weight (approx.) 2.75 lb. (1.25 kg) 
    Shipping Weight 5.5 lb. (2.5 kg) 
    T Operating 10C - 35C 
    T Maximum 40C 
    Humidity 90 non-condensing 
    Table 2 TNP355 Mechanical Specifications 
     
     
    Electrical 
     (Dual Outlet Panel) TNP355C 
    Power Rating  
     (pass-through AC power) 
    120VAC,60Hz, 
    12A 
    Power Rating 
     (USB 2.0 charging port) 5VDC, 3A total 
    Table 3 TNP355 Electrical Specifications 
     
       
    						
    							TNP355C User’s Guide 
    400-0615-001 
     
     
     
     
     
    3 
     
    5. The TNP355C Interconnect Box 
     
     Tamper resistant dual AC plugs 
     Dual built in circuitry for USB ports  
     Ultra flat surface when closed 
     Custom chrome bezel and top cover 
     Simple, drop-in installation 
     
    The TNP355C is a compact interconnect solution designed for mounting into 
    tables, podiums, or other furniture as part of a presentation system. Power 
    and USB are accessed by pushing down on the top cover allowing the unit 
    to tilt open.  
     
    The power and USB sockets are hidden by pressing down on the top cover until the latching mechanism engages. In the closed 
    position, the top cover lays almost flush with the tabletop. This tabletop solution offers dual 12 Amps AC sockets along with 2 USB ports 
    that can deliver up to 3A of charging power indicated by a green LED light.  
     
    The tabletop solution was specially designed for use with USB compatible devices. The power cable is split to deliver power to both 
    outlets on the tabletop from one AC plug. The TNP355C is one of many solutions available in the TNP Jr product line that can be 
    customized with many different connectivity options. 
      
      
    						
    							TNP355C User’s Guide 
    400-0615-001 
     
     
     
     
     
    4 
     
    6. Application Diagrams 
     
    Diagram 1: Typical Setup and use of a TNP355C 
     
     Diagram 2: Front View 
       
    						
    							TNP355C User’s Guide 
    400-0615-001 
     
     
     
     
     
    5 
     
     
    Diagram 3: Mounting the TNP355C 
     
     
    Diagram 4: Side Dimensions 
      
    Diagram 5: Top Bezel Dimensions
     
       
    						
    							TNP355C User’s Guide 
    400-0615-001 
     
     
     
     
     
    6 
     
    7. Operation 
    7.1 Opening and Closing the Tilt N Plug 
    The Tilt N Plug will open easily when the top is pressed down 
    and then released. 
    When the Tilt N Plug is not in use, simply press the top down 
    until it is level with the surface of the table and then release.  The 
    unit will remain hidden until needed again.  
    7.2 Power/Signal Connections 
    Connect external devices to the appropriate connector on the Tilt 
    N Plug. Remember, the devices plugged into the AC power 
    connectors should not draw more than 12A. 
     
     
    8. Troubleshooting Guide 
    The Tilt N Plug supplied was carefully tested and no problems were detected. However, we would like to offer the following 
    suggestions: 
    TNP 
    Symptom Resolution 
    USB ports are not 
    charging 
    1. Make sure that the power cord is connected. 
    2. Make sure the USB LED indicator is on 
    Damaged power cord 
    1. Make sure that no cable or power cord is damaged or pinched.  
    2. If there has been damage, do not use the Tilt N Plug. Please call the ALTINEX Customer 
    Service Department at (714) 990-2300 to have the unit repaired. 
    Unit raises too slowly 
    1. If the unit does not rise into position correctly, check the service loops for the signal and power 
    cords on the bottom of the unit. If the service loop is too small the cables will counteract the 
    spring trying to raise the unit into position. 
    Unit tilts up too fast 
    1. If the unit rises into position too fast, check the service loops for the signal and power cords on 
    the bottom of the unit. If the service loop is too large and the cables are putting upward pressure 
    on the unit, the unit will tilt up too fast. 
    Unit does not close all 
    the way 
    1. If the unit does not close flush with the bezel, check the service loops for the signal and power 
    cords on the bottom of the unit. If the service loop is putting upward pressure in the unit, the unit 
    will not be able to seat all the way down. 
      
    						
    All Altinex manuals Comments (0)