Version 1 103 Bauer Drive, Oakland, NJ 07436 • 800-648-7229 • Fax: 800-286-0114 www.alpha-tools.com Alpha® Filter/Regulator Manifold System Instruction Manual MANUAL Part No: 1030-0021 Part No: 1030-0022 Part No: 1030-0023 Part No: 1030-0024
Page 2
2 TABLE OF CONTENTS Introduction ........................................................................................................ 3 About the Symbols ................................................................................. 3 Installation and Maintenance for the Filter/Regulator Manifold Assembly ......... 4 Tools Needed ......................................................................................... 5 Pre-Installation...
Page 3
3 INTRODUCTION Thank you for purchasing the Alpha ® Filter/Regulator Manifold System, a system that helps eliminate potential issues caused by rust or contamination in the pipes or connectors feeding pneumatic tools. To ensure correct use, read this Instruction Manual and the Instruction Manual for the pneumatic tool and follow the operating instructions. Keep this manual in a place where operators can access it easily whenever necessary! ABOUT THE SYMBOLS According to the hazard level, all...
Page 4
4 INSTALLATION AND MAINTENANCE FOR THE FILTER/ REGULATOR MANIFOLD ASSEMBLY The F/R manifold system comes in two sizes with two choices of threads and is designed for installation at point of use. The system consists of a connection adapter block, a Filter/Regulator with auto dump valve for condensation, a 3-port pressure relief valve, an anodized aluminum manifold with quick disconnect cou- plers and plugs. The Filter/Regulator will allow you to set the pressure to the tools at 85 to 90 PSI, while...
Page 5
5 (Fig.3) Drop LegBall Valve The assemblies come completely assembled using three modular clamps. The two outer modular T-clamps are designed for mounting the unit to the wall, so the weight of the unit is not supported by the connection pipe and adapter. Note: Although the units ship with the layout direction of left to right, if the environment warrants it, the Filter/Regulator assembly can be setup to use in the opposite direction (from right to left). See Page 8 for detailed instructions on...
Page 6
6 CAUTION! The weight of the unit should not be supported by the supply piping. If your piping is mounted fl at against the wall, and you cannot connect directly to the supply line, use one of the following options to install the Alpha ® F/R Manifold Assembly. OPTION 1: ALPHA® ADAPTER AIR HOSE ASSEMBLY The Adapter Hose Assembly can be used to make the F/R Manifold Assembly easier to install. (See Fig. 4) NOTE: Adapter Hose Assembly is only available for Part No. 1030-0022 (53CFM) and 1030-0023...
Page 7
7 OPTION 2: ALPHA® MOBILE AIR HOSE ASSEMBLY The F/R Manifold assembly can be mounted directly onto your stone layout frames and/or closer to the point of use with an Alpha ® Mobile Air Hose Assembly (See Fig. 5). NOTE: Mobile Hose Assembly is only available for Part No. 1030-0022 (53CFM) and 1030-0023 (106CFM) F/R Manifolds. The Mobile Hose Assemblies are made of ½” Flexzilla hose with ½” NPT male swivel fi ttings on both ends and come in 15ft to 40ft lengths. PART NODESCRIPTION CONNECTOR...
Page 8
8 Air Flow (Left to Right) 6. Place the Modular T-clamp onto the adapter block and align so it sits fl at against the wall. 7. Level the Modular T-clamp and install a screw to support. 8. Check and make sure the rubber sealing ring is fl ush against the outsides. 9. Check and make sure the rest of the manifold assembly and clamps are fl ush to the wall. 10. Install the remaining screws to secure the modular T-clamps. 11. Connect to the air line. NOTE: If using the Alpha® Adapter Hose Assembly,...
Page 9
9 1. In order to mount the F/R Manifold on the LEFT side of the air drop line, you need to disassemble the unit and re-assemble. Using a 4mm or 5mm hex key, loosen up the hex bolts on the Modular Clamps (#2 and #4) which will allow you to remove all the components of the F/R Manifold. (See Fig. 10) NOTE: 1. 4mm hex required for the 3/8” Manifold Assembly 2. 5mm hex required for the 1/2” Manifold Assembly 2. After all components are de- tached, line up all the components in the...
Page 10
10 CHANGING THE FILTER/REGULATOR TO A RIGHT TO LEFT CONFIGURATION 1. Now that the Filter/Regulator Assembly has been changed to a RIGHT to LEFT confi guration, the pressure gauge needs to be removed and re-attached to the backside of the Filter/Regulator. 2. Remove the clear plastic cover by twisting it clockwise, remove the two screws securing the pressure gauge to the Filter/Regulator. (See Fig. 13) 3. Remove the pressure gauge by pulling it out of the Filter/Regulator. (See Fig. 14) 4. Turn...