Page 21

18
Basic Operations
Shift Direction and Offset frequency setting
Conventional repeaters are operated in the DUPLEX mode, which receives an incoming
signal on one frequency and re-transmits on another. The difference between these two fre-
quencies is called the offset frequency. The offset is variable between 0 to 99.995MHz on
this unit.
- 0.600 + 0.600
Shift release (off)
At –600kHz
1.After pressing the FUNC key, and pressing the
MHz key while [F] appears on the display, the
display will show the...

Page 22

19
Basic Operations
Memory Mode
This mode allows recalling and operating the preprogrammed frequency or setting. This unit pro-
vides up to 200 memory channels (80 exclusive channels each for VHF and UHF, from 00 to 79CH
and 40 common channels for VHF and UHF, from 100 to 139), 1 CALL channel each for V and U
(C), 1 program-scan edge memory channel each for V and U (PL) (PH) and 1 VFO automatic
Memory mode
Memory channel
In case the SUB side is in the memory mode
program setting channel (AL) (AH)....

Page 23

20
Basic Operations
 How to program memory channel (s)
1.Select a frequency to be programmed in the
VFO mode and set the parameters as appropri-
ate. Refer to the next page for programmable
parameters.
2.By pressing FUNC key, [F] and [Memory No.]
icons will appear on the display.
3.Rotate the main dial (or press Mic UP/DOWN
key) to select the desired memory channel num-
ber.
4.An empty channel is shown with a flashing
[Memory No.] icon.
5.By pressing V/M key while [F]icon is on the
display, programming...

Page 24

21
Basic Operations
Programmable data in the memory channel
Each Memory channel including 00 – 99, 100 – 39, CALL channel and AL, AH, PL, PH channel
can store following:
• Frequency
• Shift frequency
• Shift direction (+ / -)
• Tone encoder frequency
• Tone decoder frequency
• Tone encoder/decoder setting
• DCS encoder code
• DCS decoder code
• DCS setting
• Skip CH setting
• Busy channel Lock Out (BCLO)
• Digital mode setting
• Digital code
• Narrow mode setting
• AM mode setting
• Clock shift setting...

Page 25

22
Basic Operations
Channel name (Alphanumeric) registration function
The memory channels stored in the memory mode can be displayed with an alphanumeric tag
instead of the default frequency display. There are 67 characters available including A-Z, 0-9.
1.In the memory mode, select a channel to be
programmed.
2.Press the H/L key together with the FUNC key.
3.The display shows [A    ] flashing.
4.Rotate the dial to select a character to be pro-
grammed.
5.By pressing the BAND key, the character stops...

Page 26

23
Basic Operations
CALL mode
This is a memory mode that allows the transceiver to quickly recall the assigned memory channel
by simply pressing the CALL key, regardless of the current status of the unit.
The default setting is 145.00MHz/433.00MHz, and one CALL channel is available on each band.
To recall a CALL channel
Select the desired VHF or UHF band by pressing the BAND key.
1.Press the CALL key. The C icon appears on the
display and the transceiver enters the CALL
mode. In this mode, the main dial...

Page 27

24
Basic Operations
IMPORTANT: The Monitor function only operates on the MAIN band. The Monitor func-
tion operates irrespective of Tone squelch/DCS function setting.
Reverse function
This function is for monitoring the transmission frequency
instead of receiving frequency in repeater operation. This tech-
nique is commonly used to check if it is possible to commu-
nicate without using a repeater by monitoring the accessing
station’s signal strength.
When -5.000MHz SHIFT is set
1.Keep pressing the SQL...

Page 28

25
Basic Operations
To transmit
1.Set the transmission band to the MAIN side.
2.Be sure that you are authorized to operate on the
selected frequency. Check the system and monitor
the frequency to make sure that you are not going
to disturb any ongoing communications.
3.Press the PTT key on the microphone. The TX lamp (red)
illuminates to show the unit is transmitting. The SUB-
band audio mutes during the transmission. If the receiver’s
frequency combination is VHF amateur/accessory RX
band such as...

Page 29

26
Parameter Setting Mode
Press the FUNC key /UP key
Press the SQL/DOWN key Default display
 Function
STEP 20Channel Step setting
TIMERScan type switching
BEEP 2Beep sound ON/OFF
TOT OFFTime-Out-Timer ON/OFF 
TOTP OFF
TOT penalty ON/OFF
APO OFFAuto-Power-Off ON/OFF 
ALERT
Tone Burst frequency setting*
CKSFT OFFClock Shift setting     
BELL OFF
Bell function setting
BCLO OFFBusy-Channel-Lock-Out setting
SCR OFFTheft Alarm ON/OFF
COLOR 1 Illumination color switching
LAMP 4
Dimmer setting
CCall sign setting...

Page 30

27
Parameter Setting Mode
To use the parameter setting mode
1.Press the FUNC key for more than 2 seconds to
enter the parameter Setting mode.
2.Select a menu by pressing the FUNC key and
the SQL key, or UP/DOWN keys on the micro-
phone.
3.Rotate the main dial to change the setting.
4.Pressing the FUNC/SQL and UP/DOWN key
will complete the setting and enter the next
menu.
5.Pressing any key other than the FUNC/SQL or
the UP/DOWN key will complete the setting
and the unit will exit the parameter setting...