Home > Albrecht > Communications receiver > Albrecht AE80H 50-Channel Portable Scanner Owners Manual

Albrecht AE80H 50-Channel Portable Scanner Owners Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Albrecht AE80H 50-Channel Portable Scanner Owners Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 76 Albrecht manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							OWNER’S MANUAL
    AE80H
    50-Channel Portable Scanner 
    						
    							FEATURES
    Your new Albrecht AE80H 50-Channel Portable Scanner gives you direct access to over 34,000 exciting
    frequencies, including police and fire departments, ambulance services, and amateur radio services.
    You can select up to 50 channels to scan, and you can change your selection at any time.
    The secret to your scanner’s ability to scan so many frequencies is its custom-designed microprocessor
    – a tiny, built-in computer.
    Your scanner has these special features:
    10 Preprogrammed Search Bands – let you search for transmissions within preset frequency ranges,
    so you can find interesting frequencies more quickly.
    50 Channels – let you store up to 50 of your favorite frequencies for easy recall and scanning.
    Duplicate Frequency Check – automatically warns you if you try to store a frequency you’ve already
    stored, to help you use the scanner’s memory more efficiently.
    Monitor Memory – lets you temporarily save a frequency located during a direct search, so you can
    move it to channel storage later.
    Channel Lockout – keeps channels you select from being scanned.
    Memory Backup – keeps the channel frequencies stored in memory for about 1 hour during a power
    loss.
    Two-Second Scan Delay – delays scanning for 2 seconds before moving to another channel, so you
    can hear more replies.
    Key Lock – lets you lock the keys to help prevent accidentally changing the scanner’s programming.
    Flexible Antenna with BNC Connector – provides excellent reception. The BNC connector makes it
    easy to attach and remove the antenna or a variety of optional antennas.
    Liquid Crystal Display – clearly displays how the scanner is set and makes it easy to change those
    settings.
    Three Power Options – you can power the scanner from internal batteries (not supplied – including
    non-rechargeable batteries, rechargeable batteries, or a rechargeable scanner battery pack) or external
    AC or DC power (using optional adapters).
    We recommend you record your scanner’s serial number here. This number is on the scanner’s back
    panel.
    Serial Number: ____________________
    Your AE80H scanner can receive all of these frequencies:
    · 68-88 MHz (VHF-Lo)
    · 137-174 MHz (2-Meter Amateur Radio, VHF Hi)
    · 380-512 MHz (Military Aircraft, UHF Lo, 70-cm Amateur Radio, UHF „T“ Band)
    · 806-960 MHz (UHF Public Service, Trunked Services, UHF Hi, 33-cm Amateur Band (some
    countries)
    For a list of the frequency ranges in the ten preprogrammed search bands, see „Search Bands“. 
    						
    							PREPARATION
    POWER SOURCES
    You can power your scanner from any of four sources:
    . Internal batteries (not supplied) with the provided battery holder
    . A rechargeable scanner battery pack (not supplied)
    . Standard AC power (using an optional AC adapter)
    . Vehicle battery power (using an optional DC cigarette-lighter adapter)
    Notes:
    . The PWR jack lets you connect an external AC or DC adapter to operate the scanner. Connecting an
    adapter to PWR disconnects the internal batteries. You can use the PWR jack with either non-
    rechargeable or rechargeable nickel-cadmium batteries installed.
    . The CHG jack lets you connect an external AC or DC adapter to operate the scanner. The internal
    batteries remain connected when you connect an adapter to CHG, and get recharged when you connect
    a charger.
    Warning: Never use the CHG jack with non-rechargeable batteries! If you try to recharge non-
    rechargeable batteries, they could get very hot and explode.
    Using Batteries
    You can power your scanner from six AA batteries. For the longest operation and best performance, we
    recommend alkaline batteries. You can also power the scanner using a rechargeable scanner battery
    pack or rechargeable nickel-cadmium batteries, and recharge it as you use the scanner.
    Caution: Do not mix old and new batteries, different types of batteries (standard, alkaline, or
    rechargeable), or rechargeable batteries of different capacities.
    Follow these steps to install batteries or a battery pack.
    1. Press down on the battery compartment cover on the bottom of the scanner and slide the cover in the
    direction of the arrow to remove it.
    2. Slide the battery holder out of the battery compartment.
    3. If you are installing individual batteries, insert six AA batteries in the battery holder as indicated by the
    polarity symbols (+ and -) marked on the battery holder.
    4. Slide the battery holder or battery pack into the compartment.
    Caution: The battery holder or battery pack fits only one way inside the battery compartment. Do not
    force it.
    5. Replace the cover.
    When battery power is low, BATT flashes and the scanner beeps about every 3 seconds. Immediately
    replace all six non-rechargeable batteries or recharge the rechargeable batteries or battery pack.
    Caution: Always dispose of old batteries promptly and properly. Do not bury or burn them. 
    						
    							Using Standard AC Power
    To power the scanner from AC power, you need an AC adapter.
    Cautions:
    . You must use an AC adapter that supplies 9 volts and delivers at least 200 milliamps. Its center tip
    must be set to negative, and its barrel plug must correctly fit the scanner’s PWR/CHG jack. The
    recommended adapter meets these specifications. Using an adapter that does not meet these
    specifications could damage the scanner or the adapter.
    . When you finish using the AC adapter, disconnect it from the AC outlet first. Then disconnect it from
    the scanner.
    Plug the adapter’s barrel plug into the scanner’s PWR jack. Then plug the adapter’s power module into
    a standard AC outlet.
    Using Vehicle Battery Power
    To power the scanner from your vehicle’s cigarette-lighter socket, you need a DC adapter.
    Cautions:
    You must use a DC adapter that supplies 9 volts and delivers at least 200 milliamps. Its center tip must
    be set to negative, and its plug must correctly fit the scanner’s PWR/CHG jack. The recommended
    adapter meets these specifications. Using an adapter that does not meet these specifications could
    damage the scanner or the adapter.
    To protect your vehicle’s electrical system, always plug the adapter into the scanner before you plug it
    into your vehicle’s cigarette-lighter socket. Always unplug the adapter from the vehicle’s cigarette-lighter
    socket before you unplug it from the scanner.
    Plug the adapter’s barrel plug into the scanner’s PWR jack. Then plug the adapter’s power module into
    your vehicle’s cigarette-lighter socket.
    Notes:
    Mobile use of this scanner is unlawful or requires a permit in some areas. Check the laws in your area.
    If the scanner does not operate properly when you connect a DC adapter, unplug the adapter from the
    cigarette-lighter socket and clean the socket to remove ashes and other debris.
    Charging a Rechargeable Battery Pack/Rechargeable Batteries
    Your scanner has a built-in charging circuit that lets you charge a rechargeable battery pack or
    rechargeable nickel-cadmium batteries while it is in the scanner. To charge it, simply connect an AC or
    DC adapter to the scanner’s CHG jack.
    It takes about 14-16 hours to recharge a battery pack (rechargeable batteries) that is fully discharged.
    You scan operate the scanner while recharging the battery pack (rechargeable batteries), but charging
    takes longer.
    Note: A rechargeable battery pack (rechargeable batteries) lasts longer if you let it fully discharge once
    a month. To do this, simply use the scanner until BATT flashes and the scanner beeps about every 3
    seconds. Then fully charge it.
    Important! At the end of a rechargeable battery pack or batteries useful life, it must be recycled or
    disposed of properly. Contact your local, county, or state hazardous waste management authorities for
    information on recycling or disposal programs in your area. Some options that might be available are:
    municipal curb-side collection, drop-off boxes a retailers such as your local store, recycling collection
    centers, and mailback programs. 
    						
    							CONNECTING THE ANTENNA
    Follow these steps to attach the supplied flexible antenna to your scanner.
    1. Align the slots around the scanner’s connector with the tabs on the ANT jack.
    2. Press the antenna down over the jack and turn the antenna’s base clockwise until it locks into place.
    Connecting an Optional Antenna
    The ANT jack on the top of the scanner makes it easy to use the scanner with a variety of antennas.
    Instead of the supplied antenna, you can attach a different one, such as an external mobile antenna or
    outdoor base station antenna.
    Follow the installation instructions supplied with the antenna, route the antenna cable to the scanner,
    then connect it to the ANT jack.
    Warning: Use extreme caution when installing or removing an outdoor base station antenna. If the
    antenna starts to fall, let it go! It could contact overhead power lines, if the antenna touches a power
    line, contact with the antenna, mast, cable or guy wires can cause electrocution and death! Call the
    power company to remove the antenna. Do not attempt to do so yourself.
    CONNECTING AN EARPHONE/HEADPHONES
    For private listening, you can plug an earphone or mono headphones with a 3.5 mm plug into the
    PHONE jack on top of your scanner. This disconnects the internal speaker.
    Caution: To protect your hearing, follow these guidelines when you use an earphone or headphones:
    Do not listen at extremely high volume levels. Extended high-volume listening can lead to permanent
    hearing loss.
    . Once you set the volume, do not increase it. Over time, your ears adapt to the volume level, so a
    volume level that does not cause discomfort might still damage your hearing.
    Warning: Do not use an earphone or headphones with your scanner when operating a motor vehicle or
    riding a bicycle, in or near traffic. Doing so can create a traffic hazard and could be illegal in some
    areas.
    CONNECTING AN EXTENSION SPEAKER
    In a noisy area, an extension speaker or an amplified speaker might provide more comfortable
    listening.
    Plug the speaker cable’s 3.5 mm plug into your scanner’s PHONE jack.
    USING THE BELT CLIP
    You can use the belt clip for hands-free carrying when you are on the go. Simply slide the belt clip over
    your belt or waistband. 
    						
    							YOUR SCANNER
    A LOOK AT THE KEYPAD
    Your scanner’s keys might seem confusing at first but this information should help you understand each
    key’s function.
    SCAN – scans through the programmed channels.
    MANUAL – stops scanning to let you directly enter a channel number.
    BAND – selects a preprogrammed search band.
    MON – accesses the monitor memory.
    LICHT – turns on/off the display’s backlight
    / or \/ -- searches down or up from the currently displayed frequency, or selects the direction when you
    scan channels.
    (key symbol) – locks/unlocks the keypad to prevent accidental entries.
    CLEAR – clears an incorrect entry.
    PGM – lets you program frequencies into channels.
    Number Keys – use these keys to enter the numbers for a channel or frequency.
    DLY/. (delay/decimal point) – programs a 2-second delay for the selected channel, or enters a decimal
    point (necessary when programming frequencies).
    L-OUT/E (lockout/enter) – locks out channels so they will not be scanned, or enters frequencies into
    channels.
    A LOOK AT THE DISPLAY
    The display has indicators that show the scanner’s current operation.
    MAN – appears when you manually select a channel.
    SCAN – appears when you scan channels.
    MON – appears when you listen to the monitor memory.
    BATT – appears when battery power is low.
    L/O – appears when you manually select a channel you locked out.
    SRCH – appears during a band or direct frequency search.
    / or \/ -- indicates the search or scan direction.
    DELAY – appears when you program a 2-seconds delay for a channel. 
    						
    							PGM – appears while you program frequencies into the scanner’s channels.
    (key symbol) – appears when you lock the keypad.
    ch – appears after the digits (1-50) that show which channel the scanner is tuned to.
    -d – appears during a direct frequency search.
    000.000 – the digits on the right of the display show which frequency the scanner is tuned to.
    Error – appears when you make an entry error.
    dUPL (duplicate) – appears when you try to store a frequency that is already stored in another channel.
    UNDERSTANDING BANDS/MONITOR MEMORY
    Search Bands
    Your scanner can tune over 34,000 different frequencies. Many of these frequencies are grouped within
    permanent memory locations called search bands.
    BandDisplayed Search Range (MHz)Description
    068-78VHF Lo
    178-88VHF-Lo
    2137-144Aircraft/Air Shows, VHF
    3144-1482-Meter Amateur Radio
    4148-174VHF Hi
    5380-420UHF Lo
    6420-45070-Centimeter Amateur Radio
    7450-512UHF Lo
    8806-870UHF „T“ Band
    9870-960UHF Hi
    You can search these bands to quickly find active frequencies you might want to store into the scanner’s
    channels. For example, if you wanted to search for transmissions between amateur radio operators,
    you could search only the search bands where you are most likely to hear the transmissions (Bands 3,
    and 6).
    Note: The frequencies in the scanner’s search bands are preset. You cannot change them.
    Monitor Memory
    The scanner also has a monitor memory that you can use to temporarily store a frequency while you
    decide whether to save it into a channel. This is handy for quickly storing an active frequency when you
    are searching through an entire band using direct search. See „Direct Search“. 
    						
    							0PERATION
    TURNING ON THE SCANNER/SETTING VOLUME AND SQUELCH
    Note: Make sure the scanner’s antenna is connected before you turn it on.
    1. Turn SQUELCH fully counterclockwise.
    2. Turn VOLUME clockwise until it clicks and you hear a hissing sound.
    3. Turn SQUELCH clockwise until the hissing sound stops.
    Notes:
    . If the scanner picks up unwanted, partial, or very weak transmissions, turn SQUELCH clockwise to
    decrease the scanner’s sensitivity to these signals. If you want to listen to a weak or distant station, turn
    SQUELCH counterclockwise.
    . If SQUELCH is adjusted so you always hear a hissing sound, the scanner does not scan properly.
    . If you have not stored frequencies into any channels, the scanner does not scan.
    STORING ACTIVE FREQUENCIES
    You can manually store frequencies you already know into the scanner’s channels. You can also store
    frequencies you found using band search directly into channels. You can also store a frequency into a
    monitor memory then store it into a channel.
    If you do not have a reference to frequencies in your area, follow the steps in „Band Search“ on Page ??
    or „Direct Search“  to search for transmissions.
    Manually Storing Frequencies
    If you know a frequency you want to store, you can store it manually.
    1. Press PGM. PGM appears.
    2. Use the number keys to enter the channel number where you want to store the frequency (1-50), then
    press PGM again. Or, repeatedly press PGM until the desired channel number appears.
    3. Use the number keys and DLY/. to enter the frequency (including the decimal point) you want to store
    into that channel.
    4. Press E to store the frequency.
    Notes:
    If you entered an invalid frequency in Step 3, Error appears, the channel number flashes, and the
    scanner beeps three times after you press E. Simply repeat Steps 3 and 4.
    Your scanner automatically rounds the entered frequency down to the nearest valid frequency. For
    example, if you enter a frequency of 151.4730, your scanner accepts it as 151.4700.
    If you entered a frequency that is already stored in another channel, dUPL (duplicate) and the lowest-
    numbered channel containing the duplicate frequency flash for about 3 seconds. To store the frequency
    anyway, press E again.
    5. Repeat Steps 2-4 to store more frequencies into channels. 
    						
    							Band Search
    If you do not know of a frequency to store, you can search your scanner’s preprogrammed search
    bands (see „Search Bands“) for active frequencies, then store any that you find into your scanner’s
    channels.
    Follow these steps to search for and store active frequencies using band search.
    1. Press BAND. The last selected band number (B followed by the band number) and the frequency
    search range appear for about 2 seconds.
    2. To select a different band within 2 seconds, enter the band’s number (0-9) or repeatedly press BAND
    until the desired band number appears.
    After about 2 seconds, SRCH / appears, the next available channel flashes, and the scanner begins
    searching rapidly upward in that band (from lowest to highest frequency) for an active frequency.
    Notes:
    To reverse the search direction at any time, hold down \/ for about 1 second.
    To search the band upward or downward in small increments (in steps or 5 of 12.5 kHz, depending on
    the band), repeatedly press and release / or \/.
    To select a different band after the scanner begins searching the current band, simply repeat Step 2.
    The scanner stops when it finds an active frequency.
    3. To store the displayed frequency in the channel currently flashing on the display, press E. The
    scanner stores the frequency, then the next available channel flashes and continue the search.
    Notes:
    You cannot store a frequency in the monitor memory during band search.
    After you store a frequency into the last available channel, --ch appears instead of a channel number. If
    you try to store a channel while --ch appears, Ch FULL appears briefly. In order to store more
    frequencies, you must clear some channels. See „Clearing a Channel“ on Page ??.
    4. To search for another active frequency in the selected band, hold down / or \/ for about 1 second.
    Direct Search
    You can search up or down from the currently displayed frequency and store the frequency into the
    monitor memory.
    1. Press MANUAL or PGM, then use the number keys and DLY/. to enter the frequency where you want
    to start the search.
    Note: To start from a frequency already stored in one of your scanner’s channels, press MANUAL or
    PGM, enter the desired channel number, then press MANUAL or PGM again.
    2. Hold down / or \/ for about 1 second to search up or down from the selected frequency.
    When the scanner finds an active frequency, it stops searching.
    3. To store the frequency in the monitor memory, simply press MON. MON appears on the display.
    4. To continue the search, hold down / or \/ for about 1 second. 
    						
    							MOVING A FREQUENCY FROM THE MONITOR MEMORY TO A CHANNEL
    1. Press MANUAL, enter the channel number where you want to store the frequency, then press PGM.
    PGM, the frequency number or 000.0000, and the selected channel number appear.
    2. Press MON. MON and the frequency appear and the channel number flashes.
    3. Press E. MON disappears, the channel number stops flashing, and the scanner stores the frequency
    in the selected channel.
    MONITORING A STORED CHANNEL
    You can continuously monitor a specific channel without scanning. This is useful if you hear an
    emergency broadcast on a channel and do not want to miss any details – even though there might be
    periods of silence – or if you simply want to monitor that channel.
    Follow these steps to manually select a channel.
    1. Press MANUAL.
    2. Enter the channel number.
    3. Press MANUAL again.
    SCANNING THE CHANNELS
    To begin scanning channels or to start scanning again after monitoring a specific channel, press SCAN.
    SCAN and / appear, and the scanner begins to rapidly scan upward until it finds an active frequency.
    If the scanner finds an active frequency, it stops and displays that channel and frequency number, then
    it automatically begins scanning again when the transmission ends on that frequency.
    Notes:
    You must store frequencies into channels before the scanner can scan them.
    To change the scanning direction, press / or \/.
    The scanner does not scan empty channels.
    LISTENING TO THE MONITOR MEMORY
    To listen to the frequency stored in the monitor memory, press MANUAL then MON. MAN, MON and the
    frequency stored in the monitor memory appear.
    CLEARING A CHANNEL
    1. Press MANUAL.
    2. Use the number keys to enter the channel number containing the frequency you want to delete, then
    press PGM. Or, repeatedly press PGM until the desired channel number appears. PGM appears.
    3. Press CLEAR. The frequency number flashes.
    4. Press L-OUT. L/O (lockout – see „Locking Out a Channel“ on Page ??) appears, the channel number
    flashes, and the frequency number changes to 000.0000 to indicate the frequency is cleared.
    5. To delete more frequencies, repeat Steps 2-4. 
    						
    All Albrecht manuals Comments (0)

    Related Manuals for Albrecht AE80H 50-Channel Portable Scanner Owners Manual