Page 21
21 Note: When you store frequency while all channels entered, CH FULL appears. In order to store more frequencies, you must clear some channels. See Deleting Frequencies on Page 22. 6. To store that frequency in the monitor memory, simply press MON. To search for another active frequency in the selected band, press and hold / or \/ for about a second, then repeat Step 4. Tips for direct search You can search frequencies within the range of 1 to 10 MHz as follows: 1. Press MAN or PGM. 2. Use the number...
Page 22
22 To begin scanning channels or to start scanning again after monitoring a specific channel, press SCAN. Notes: l You must store frequencies into channels before the scanner can scan them (see Searching For and Storing Active Frequencies on Page 13). l The scanner does not scan empty channels. The scanner scans through all channels (except those you have locked out) in the active banks (see Locking Out Channels and Frequencies on Page 25 and Turning Channel-Storage Banks Off and On on Page 21). To...
Page 23
23 TURNING CHANNEL-STORAGE BANKS OFF AND ON To turn off banks while scanning, press the banks number key until the bar under the banks number disappears. The scanner does not scan any of the channels within the banks you have turned off. Notes: l You cannot turn off all banks. There must be at least one active bank. l You can manually select any channel in a bank, even if the bank is turned off. To turn on banks while scanning, press the banks number key until a bar appears under the banks number. MOVING...
Page 24
24 1. Press AUTO. AUTO appears. 2. Pressing AUTO key or turn TUNE knob, to select the channel bank where you want to store monitor memory frequencies. If you select a bank that contains at least one empty channel, a bar flashes under the bank number, and AC-, the number of empty channels in the bank, CH, and AUTO appears. Notes: l To select bank 10, press 0. l If you do not want to select the bank, press the banks number key. If you select a bank that does not contain any empty channels, a bar flashes...
Page 25
25 2. Use the number keys to enter the channel number or monitor memory containing the frequency you want to delete. 3. If you are deleting the frequency in a channel, press PGM. If you are deleting the frequency in a monitor memory, press MON. 4. Press 0, then press ENTER. The frequency is deleted. Deleting Frequencies from All Locked-Out Channels Within a Bank You can delete the frequencies in all locked-out channels within a bank (see Locking Out Channels and Frequencies on Page 25). This lets you...
Page 26
26 1. Press AUTO. AUTO appears. 2. Pressing AUTO keys or turn TUNE knob, to select the channel bank. 3. Press and hold down ENTER, then press / to sort channels from the lowest to the highest frequency, or press \/ to sort channels from the highest to the lowest frequency. As the scanner sorts the frequencies, Sor. appears on the display. USING MONITOR MEMORIES Monitor memories are temporary storage areas where you can store up to 50 frequencies while you decide whether or not to save them into...
Page 27
27 SPECIAL FEATURES DELAY Many agencies use a two-way radio system that might have a pause of several seconds between a query and a reply. Your scanners delay feature lets it wait for 2 seconds after each transmission on a channel or frequency while scanning or searching. To program a 2-second delay for a channel while scanning, manually select the channel and press FUNC then press DELAY/CL until DELAY appears. When your scanner stops on the channel, it waits for 2 seconds after each transmission on...
Page 28
28 To lock out a frequency during a each search mode, press L/OUT when the scanner stops on the frequency. The scanner locks out the frequency, then continues searching. Notes: l The scanner does not store locked-out frequencies during search. l You can lock out as many as 200 frequencies. If you try to lock out more than 200 frequencies, L-FULL appears on the display. Follow these steps to remove the lock-out from a frequency. 1. Press BAND or LIMIT or DIRECT/· to enter search operation. 2. Press L/O...
Page 29
29 With the priority feature, you can scan through programmed channels and still not miss an important or interesting call on a specific channel. You can program ten priority channel. Follow these steps to program the channels as the priority channel. 1. Press PGM. 2. To select the channel where you want to store the frequency, use the number keys to enter the priority channel number (1-10), then press PRI. 3. Using the number keys, enter the frequency you want to store into that channel. 4. Press ENTER...
Page 30
30 CHANGING THE AM/FM/WFM RECEIVE MODE The scanner is preset to the most common AM/FM/WFM receive mode for each frequency range. The preset modes are: Frequency Band (MHz)Receive Mode 25.000-87.495FM 87.500-107.950WFM 108.000-136.975AM 137.000-224.995`FM 225.000-399.9875AM 400.000-1300.000FM The preset mode is correct in most cases. However, some ham radio broadcasts do not operate in the preset mode. If you try to listen to a broadcast when the scanner is not set to the correct receive mode, the...