T3 Prox Keypad Programming – Cheat Sheet Factory Code = 123456 1. Enter Program Mode(wait for Green light, before pressing AL button) 1 2 3 4 5 6 AL All programming functions are performed while the lock is in program mode. 2. Change Factory Code to New Master Code (Must be 6 digits) AL 1 AL AL * (Enter Master Code) (Re Enter Master Code) 3. Enter Date AL 38 AL * (Enter Month Day Year- Use MMDDYY) 4. Enter Time AL 39 AL * (Enter Military Time) 5. Enter Day of Week AL 40 AL * (Enter 1 – 7, 1 = Sun, 7 = Sat) 6. Add New Users: Prox Card Only AL 2 AL * Present Card AL 2 AL * Present Card (User ID #) 7. Add New Users: Pin Only AL 2 AL AL * AL 2 AL AL * (User ID #) (Enter User code 3–6 digits) 8. Add New Users requiring Prox Card & Pin Number (Use Steps 6 & 7 for each user requiring Prox & Pin) AL 2 AL AL * AL 2 AL * Present Card 9. User Enable with Timeout AL 5 AL AL * (User ID #) (Enter 1 – 999 hours) 10. Passage Mode AL 45 * 11. Re-lock Mode AL 46 * 12. Timed Passage Mode AL 47 * (Enter 1 – 999 hours) 13. Print Audit Trail IR1 AL 55 *