    Have a look at the manual Alarm Lock New KEY LOGGING FeatureWiring Instructions User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 84 Alarm Lock manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							ADDENDUM  
    NEW KEY LOGGING FEATURE  
    WI1587  1/07 
     
     
     
     
     
     
    The new Key Logging feature creates an entry in the Audit Log when a conventional key is used for entry.  Two sample log 
    entries are shown below, one printed, the other as displayed in DL-Windows.  To enable Key Logging, simply connect the 
    wires as shown in the images at the bottom. 
    345 Bayview Avenue 
    Amityville, New York 11701 
    For Sales and Repairs 1-800-ALA-LOCK 
    For Technical Service 1-800-645-9440 
    Publicly traded on NASDAQ    Symbol: NSSC 
    © ALARM LOCK 2007 
    HOW TO ROUTE AND CONNECT THE WIRES 
    1. Route wires through door as shown.  The 
    cylinder housing has two terminal housings, 
    and each housing contains two wires -- one 
    housing contains red/black wires, the other 
    black/black. 
    ------- AUDIT LOG -------   
    01/16/07 13:06:35 Tue 
     13:01:59  001 PROGRAM 56 
     13:01:29  001 PROGRAM 57 
     13:00:53  001 ENTRY 
     13:00:26  013 ENTRY 
     13:00:17  KEY ENTRY 
     13:00:03  012 ENTRY 
     12:56:27  001 PROGRAM 2 
     12:56:27  001 PROGRAM 40 
     12:56:04  001 PROGRAM 39 
     12:55:00  NEW CLCK TIME 
     12:01:39  OLD CLCK TIME 
     12:00:45  RAM TEST:PASS 
     12:00:45  POWER UP 
    ------------------------- 
    End of Audit Log  
    Sample log entry printed by the AL-
    IR1 infrared printer. 
    Sample log entry as displayed by  
    DL-Windows (v3.6.0 or later). 
    Be sure two wires 
    are side-by-side 
    and do not overlap 
    2. After installing the inside housing, be 
    certain wires are not pinched between 
    the housing and the mounting plate. 
    Hold-down 
    clamp 
    3.    Plug in each pair of connectors.  Verify that the 
    wire colors in each pair of female and male terminal 
    housings are the same -- red/black to red/black
     and 
    black/black to black/black. 
    Red/Black 
    to 
    Red/Black Black/Black 
    to 
    Black/Black 
    Red/
    black 
    wires 
    Black/
    black 
    wires  
    						