Have a look at the manual Alarm Lock Lever Spring Replacement Kit User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 84 Alarm Lock manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
ADDENDUM LEVER SPRING REPLACEMENT KIT WI1368 11/04 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 Publicly traded on NASDAQ Symbol: NSSC © ALARM LOCK 2004 HOW TO REPLACE THE LEVER SPRING (PART HW1220) 2. Remove the Lever Handle Spring (HW571) and set aside. A new spring will be substituted during reassembly (step 7). 1. With outside housing removed from door, unscrew two screws and remove the Spring Cover Plate (HW565) as shown. 3. Remove Connector Plate (HW570). 5. Insert Plastic Ring (HW573). 4. Remove Lever Connector (HW572). 8. Replace the Spring Cover Plate (HW565) and secure with two screws. APPLICABLE MODELS DL2700 DL3000 PDL3000 DL4100 PDL4100 DL2800 Spring Cover Plate (HW565) Screws (2) Connector Plate (HW570) Lever Connector (HW572) Outside Housing Lever Handle Spring Old Spring (HW571) New Spring (HW1220) Plastic Ring (HW573) Spring Cover Plate Lever Connector 6. Replace Lever Connector (HW572) and Connector Plate (HW570). 7. Install new Lever Handle Spring (HW1220) in place of old spring (HW751). Do not re-use spring Connector Plate New Plastic Ring Connector Plate (HW570) Lever Connector (HW572) New Lever Handle Spring (HW1220)