Alarm Lock Door Alarms PG21 Series Installation Instructions
Here you can view all the pages of manual Alarm Lock Door Alarms PG21 Series Installation Instructions. The Alarm Lock manuals for Alarm Lock are available online for free. You can easily download all the documents as PDF.
Page 1
1 PG21 Series Pilfergard Door Alarms INSTALLATION INSTRUCTIONS WI738F 1/06 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs, (800) 645-9445 For Technical Service, (800) 645-9440 © ALARM LOCK 2006 AL ARM LOCK DESCRIPTION The PG21 is a microprocessor-controlled door alarm for sur- face mounting on a door or door frame. Typical applications include emergency fire escape doors, nursing home stairwell doors, rear restaurant and theater doors. The PG21 is de- signed to...
Page 2
2 7. Position the Magnetic Actuator as indicated by the red sticker on the side of the Housing Cover. If stickers were removed, use the Magnet Alignment Mode (see page 3) or place the Magnetic Actuator 1½ from the bottom edge of the Baseplate. Mark holes and (as with the Baseplate) use a 1/8 (0.125) bit, and drill the hole 1 deep. 8. Install the Magnetic Actuator with the supplied #8 sheet- metal screws (1). Be sure to insert the Magnet (P1358) and Magnet Cover (P0291) into the Magnet...
Page 3
3 2. Reed selection jumper W1 is located in the center of the PCB. The jumper should be set to the side of the unit that will have the magnet installed. (See Figure 5 below). 3. Select jumper options (J1- J9) as follows. (Refer to the Jumper Options table, below and page 5). Important: The jumpers are only read at startup and when- ever the unit is armed. If the jumpers are changed after power up, the unit must be rearmed before the jumper changes take effect....
Page 4
4 D. MOUNTING Before mounting, install a mortise cylinder into the Housing Cover (H354-28) as follows: 1. Referring to the Figure 5 at right, (a) install mortise cylinder (Alarm Lock Model CEM, optional) into the Housing Cover from the outside with the key slot at the 6 oclock position; (b) install the Locking Arm (HW1154). Be sure to route the strobe wire under the Locking Arm to avoid interfer- ence (see Fig 5b), then screw the Lock Ring (P1267) onto...
Page 5
5 MODE NAME FEATURE DETAILS JUMPER POSITIONS Factory Default Highest Security Fire/Emergency Exit Door Nursing Home Stairwell Door Delivery Door--Latching Alarm Opening door without key while armed causes a latching alarm (key required to silence). Key required to exit and to turn off siren after an alarm. Alarm siren time-out: 2 minutes. After time-out, LED flashes. Door can be propped open indefinitely, as follows: Turn key to the left while opening door (this avoids alarm). After...
Page 6
6 MODE NAME FEATURE DETAILS JUMPER POSITIONS For Multiple Door Installa- tions A PG21 installed on several doors each with its unique siren sound. Four siren sounds: Sweep, Pulsing Sweep, Steady, Pulsing Steady. Set a different siren sound for each door in order to easily identify which door has been accessed. Jumpers 1 and 2 are config- ured. Sweep Pulsing Sweep Steady Pulsing Steady Door Ajar Mode Exit/Entry Door without Key Needed No Key Passage Mode Friendly...
Page 8
8 ALARM LOCK LIMITED WARRANTY ALARM LOCK SECURITY SYSTEMS, INC. (ALARM LOCK) warrants its products to be free from manufacturing defects in materials and workmanship for 24 months following the date of manufacture. ALARM LOCK will, within said period, at its option, repair or replace any product failing to operate correctly without charge to the original purchaser or user. This warranty shall not apply to any equipment, or any part thereof, which has been repaired by others, improperly installed,...