Home
>
Alarm Lock
>
Alarm Lock
>
Alarm Lock Daylight Saving Time Firmware Technical Note User Manual
Alarm Lock Daylight Saving Time Firmware Technical Note User Manual
Have a look at the manual Alarm Lock Daylight Saving Time Firmware Technical Note User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 84 Alarm Lock manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
1 DAYLIGHT SAVING TIME… Alarm Lock Systems, Inc. 345 Bayview Avenue Amityville NY 11701 800-252-5625 02/05/07 Alarm Lock T3 & T3 Prox Trilogy’s have been manufactured since 1998 with firmware that automatically adjusts the clock for Daylight Saving Time. As you may know, Congress recently passed an energy bill that included extending Daylight Saving Time by about a month. Beginning in 2007, DST will start the second Sunday of March and end on the first Sunday of November. This will cause the locks to adjust three weeks late in the spring and one week early in the fall. Current models have begun shipping with new firmware that will adjust to the new settings. These models will require DL-Windows V3.6 or higher to program the new DST. o PDL3000 V40B - Triangle #17 printed on the box o DL3000 V34K - Triangle #4 printed on the box o DL2800 V35G – Triangle #4 printed on the box o Balance of models to follow There are three choices in handling the DST issue: • Leave all existing or installed T3 & T3 Prox Trilogy’s with DST enabled (factory default) and they will still change the time at the old DST dates. This means that the clock will be off just the 3 weeks in the beginning and 1 week at the end of the new DST. So by doing nothing, the clock will still adjust twice a year, just to the old DST. For some companies, they will have no issues with this; they will simply adjust the records to reflect old DST • Disable the DST setting so the lock will not adjust for DST at all. All existing Trilogy locks will have to be visited twice a year to manually program the correct time (DST), either thru keypad programming or using V3.6 or higher software. • Replace the lock with a new one that is running the new firmware and program it with DL-Windows V3.6. Remember: • The firmware or chips that control these settings in existing locks cannot be changed or upgraded for the new DST. The firmware is soldered to an electronic board inside the lock and is typically potted, there is no way to remove and replace the firmware. • Simply having V3.6 software and an existing Trilogy lock will not adjust the clock to the new DST. It will also require a lock with the newer firmware. • Existing Trilogy’s will not automatically change the clock twice a year to coincide with the new DST, regardless of which version of software is used to program the lock. • There are two components required to allow the programming of the new DST to automatically have the clock self adjust in March and November of each year. o Trilogy’s with the new firmware as outlined above o V3.6 or higher software • Once Congress made the new DST official, we began to develop new firmware for each T3 lock model for the new DST.