AL-DTM-III PROCEDURAL CHANGES FOR THE PL3000 / PL3500 The procedure below is required only when a PC or DTM communication Function Card is not presently enrolled in the lock; i.e. the lock is new (out-of- box), or the lock has had all programming erased (restoring factory default). PC/DTM Communications Previous versions of the AL-DTM did not require the 299 code (Function Card #2) to be presented twice; the AL-DTM-III does require Function Card #2 to be presented twice, and therefore the AL-DTM 299 Function Card #2 must be enrolled into the lock prior to using the AL-DTM-III. Note: When using the new PL3500 with DL-Windows 3.5 (or higher), the AL- DTM-III must be used. Direct PC communications is not currently supported, and the PL3500 must be setup as a PL3000 lock-type in DL-Windows 3.5 (or higher). Procedure: All lock programming MUST be erased to restore the out of box factory de- fault, as follows: PL3000: Follow the Erase All Programming instructions in the Wiring and Power Up section in WI1280, in which the shunt connector is plugged into the yellow wire connector. PL3500: Power up the lock, wait and listen for three beeps, then hold down the out- side lever. After erasing all lock programming, both lock models wait for a proximity card to be presented. Therefore, present a proximity card (to place the lock into learn mode), then immediately present the first two Function Cards (card #1 for initi- ating PC communications, card #2 for initiating AL-DTM communications). Af- ter cards #1 and 2 have been presented and enrolled, wait for the lock to time- out and lock. Now the PL3000 can be programmed by the PC or the AL-DTM-III. Currently, the PL3500 can only be programmed by the AL-DTM-III; the PL3500 is not sup- ported by DL-Windows at this time. © ALARM LOCK 2006 WI1457A 3/06 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 Publicly traded on NASDAQ Symbol: NSSC AL-DTM-III PROCEDURAL CHANGES FOR THE PL3000 / PL3500 The procedure below is required only when a PC or DTM communication Function Card is not presently enrolled in the lock; i.e. the lock is new (out-of- box), or the lock has had all programming erased (restoring factory default). PC/DTM Communications Previous versions of the AL-DTM did not require the 299 code (Function Card #2) to be presented twice; the AL-DTM-III does require Function Card #2 to be presented twice, and therefore the AL-DTM 299 Function Card #2 must be enrolled into the lock prior to using the AL-DTM-III. Note: When using the new PL3500 with DL-Windows 3.5 (or higher), the AL- DTM-III must be used. Direct PC communications is not currently supported, and the PL3500 must be setup as a PL3000 lock-type in DL-Windows 3.5 (or higher). Procedure: All lock programming MUST be erased to restore the out of box factory de- fault, as follows: PL3000: Follow the Erase All Programming instructions in the Wiring and Power Up section in WI1280, in which the shunt connector is plugged into the yellow wire connector. PL3500: Power up the lock, wait and listen for three beeps, then hold down the out- side lever. After erasing all lock programming, both lock models wait for a proximity card to be presented. Therefore, present a proximity card (to place the lock into learn mode), then immediately present the first two Function Cards (card #1 for initi- ating PC communications, card #2 for initiating AL-DTM communications). Af- ter cards #1 and 2 have been presented and enrolled, wait for the lock to time- out and lock. Now the PL3000 can be programmed by the PC or the AL-DTM-III. Currently, the PL3500 can only be programmed by the AL-DTM-III; the PL3500 is not sup- ported by DL-Windows at this time. © ALARM LOCK 2006 WI1457A 3/06 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 Publicly traded on NASDAQ Symbol: NSSC