Alan AE108H Operating Guide
Here you can view all the pages of manual Alan AE108H Operating Guide. The Alan manuals for Communications receiver are available online for free. You can easily download all the documents as PDF.
Page 21
Scanning Bank Scanning 1.IfSCANis not indicated on the display, press . TheAE180Hshould begin scanning. The indicators for the selected Banks ( 1through10) appear on the display. The indicator of the Bank currently being monitored flashes. While theAE180His scanning, the word SCANmoves across the display. Scanning stops on any active channel that is not “Locked Out”, and displays the Channel Number and frequency or Alpha Name. Scanning resumes automatically after the transmission stops. 2.You can...
Page 22
To access a specific channel: 1.Press . 2.Enter the channel number using the numeric keys. 3.Press again. Priority Scan TheAE180Hhas 10 Priority Channels, 1 per Bank. Initially these are the first channel in each Bank. (e.g. Channel 1, Channel 11, Channel 21, and so on.) In priority scan mode, the scanner checks the Priority Channel(s) every 2 seconds during the Scan cycle. If a transmission is received, the scanner will stop at that channel. If the Priority Channel in any Bank is “Locked Out”, it will...
Page 23
Locking Out Channels You may have programmed certain channels that you do not want to hear every time you scan. These might be channels that are busy a major portion of the time, causing the scanner to stop at the channel(s) often enough to interrupt the scan cycle. You can Lock Out those channels so they are not scanned. 1.Go directly to the channel using any of the methods described above. 2.Press .L/Oappears on the display. That channel is now “Locked Out” of the scanning cycle. To include the channel...
Page 24
Searching Band Search TheAE180Hhas 13 Preprogrammed Search Bands. You can search any of these Bands to find desired frequencies if you do not have a Frequency Directory handy, or if new stations have been added since the Directory was published. 1.Press and hold /BANDto enter the Band Search Mode. Then the upper and lower limits of the band currently selected are displayed. 2.Use VFO control, or to select the band you wish to search. 3.Wait for about 2 seconds and theAE180Hwill begin searching that Band....
Page 25
4.Enter the higher limit of your search range. 5.Press . Using the Limit Search 1. Press /BANDto enter Limit Search mode. 2.Press or to stop searching. (”HOLD” appears on the display.) VFO search You can search by using VFO control. 1.In Manual mode, enter the frequency by using the number keypad and turnVFO control. -- OR -- In Band Search or Limit Search, press then enter the frequency by using the number keypad, and turn the VFO control. “V” appears on the display. 2.Turn the VFO control clockwise to...
Page 26
Care and Maintenance Replacing the Battery Pack 1. Turn the On-Off/Volume Control OFF. 2. Turn the scanner over so you are looking at the back. If the Belt clip is attached, remove it by taking out the two screws. 3. Press in on the ribbed area and slide the Battery Cover down and off. 4. Carefully unplug the Battery pack and lift it out of the case. You may need to exert slight pressure toward the top of the scanner as you slide the Battery Pack out of the case. 5. Carefully plug in the new Battery...
Page 27
6. Insert the Battery Pack by placing the bottom in the case first. Make sure it is seated within the case before replacing the Battery Cover. 7. Replace the Battery Cover by putting the two tabs in the corresponding opening and sliding it upward until it locks in place. Location If strong interference or electrical noise is received, relocate the scanner or its antenna away from the source of the noise. A higher elevation, if possible, may provide better reception. Do notuse the scanner in...
Page 28
Birdies All scanners are subject to receiving undesired signals or birdies. If your scanner stops during SEARCH Mode and no sound is heard, it may be receiving a birdie. Birdies are internally generated signals inherent in the electronics of the scanner. Use the Search Skip feature to skip the unwanted frequencies. Proper Care of Your Scanner Use only the AC Adapter/Charger that came with your scanner. Do not leave the AC Adapter/Charger plugged in for long periods. Avoid placing the scanner in direct...
Page 29
Optional Accessories and Replacement Parts ITEM PART NO. Spare Battery Pack BP-180 Replacement Rubber Antenna AT-396 Earphone EP-009 AC Adapter/Charger AD-235 Straight Cigarette LighterPower Cord(fused)UA-502 Coiled Cigarette Lighter Power Cord (fused)UA-502A Belt Clip with 2 screws BCK-150 AE180H Operating Guide OM AE180H 26 30 Y:...UB302BH(AE180H).vp Tue Jul 08 16:25:39 2003 Color profile: Disabled Composite Default screen
Page 30
Troubleshooting If yourAE180His not performing properly, try the steps listed below. PROBLEM SOLUTION Scanner won’t work. Check the power connections. Check the volume and squelch. Make sure the power switch is turned on. Improper reception. Check the antenna connection. You may be in a fringe area. Reposition the scanner. Scan won’t stop. Adjust the Squelch Control. Check the antenna connection. It is possible that none of the programmed frequencies are active at the time. Try Band Search. Scan won’t...