Selective Metal Detector «Sorex» 7281. Operating manual AKA LLC+7(495)623-4026 621-0481 http://aka.2000.ru [email protected] 11 «S» menu. To enter the «S» menu press and hold on the device panel. To browse its entries press the same button several times. To adjust parameters use buttons and . Press for exit or automatic exit 7 seconds after the end of the adjustment Menu entries. 1. General Boost 2. FGR Filter (false ground response) 3. HRN (hot rock neutralization) on/off 4....
Page 12
Selective Metal Detector «Sorex» 7281. Operating manual AKA LLC+7(495)623-4026 621-0481 http://aka.2000.ru [email protected] 12 HRN (Hot rock neutralization) on/off. This option allows turning on/off non-discrimination algorithm of hot rock signal neutralization. When it is turned on, most of the round-shaped rocks do not give identification signal, only the threshold tone with a light sound increase appears. The search becomes more comfortable in the area...
Page 13
Selective Metal Detector «Sorex» 7281. Operating manual AKA LLC+7(495)623-4026 621-0481 http://aka.2000.ru [email protected] 13 Economy mode (only for version 1.04) The key feature of this mode is a shift to a low power consumption resulted from the reduction of ECC excitation current. Upon that, detectors runtime may reach 40 hours (with 2800 mAh battery). Besides, this mode allows performing ground balancing more accurately when working at the highly mineralized...
Page 14
Selective Metal Detector «Sorex» 7281. Operating manual AKA LLC+7(495)623-4026 621-0481 http://aka.2000.ru [email protected] 14 set a piece of ferrite to the centre of the search coil surface from the distance of 25-30 cm, finishing the balancing. Puzzled? Lets make it easier: Take a CD and pass it flatwise in front of the search coil. If the CD gives vertical hodograph and VDI within -1 0 +1, then the device is ready for the air tests. If VDI of the CD differs from these...
Page 15
Selective Metal Detector «Sorex» 7281. Operating manual AKA LLC+7(495)623-4026 621-0481 http://aka.2000.ru [email protected] 15 After you have learned how to choose the balancing area, memorize the approximate balance digit in lower left corner of the screen in the balancing mode. Its sharp difference, especially in same weather conditions, during next balancing may be caused by metal in the ground, and you should change the ground balancing area for...
Page 16
Selective Metal Detector «Sorex» 7281. Operating manual AKA LLC+7(495)623-4026 621-0481 http://aka.2000.ru [email protected] 16 Find a clear area, 60 cm wide. Go to manual setup mode and making short horizontal search passes (but quicker) with a 50 cm amplitude, 3-5 cm above the ground, you will see a straight ground line on the screen (if it jerks, there is a metal). Upon that, if the balance is incorrect, you will hear a buzz from the ground and onscreen ground line...
Page 17
Selective Metal Detector «Sorex» 7281. Operating manual AKA LLC+7(495)623-4026 621-0481 http://aka.2000.ru [email protected] 17 choose the optimum frequency of the excitation current for these temperature conditions. Thereby all basic device parameters are sure to be kept, including absorbed current. In sea beach operations and other complicated soils with high conductivity we recommend to use the General Boost option for better balancing accuracy. Sometimes...
Page 18
Selective Metal Detector «Sorex» 7281. Operating manual AKA LLC+7(495)623-4026 621-0481 http://aka.2000.ru [email protected] 18 Position of some metal targets on the VDI scale(for 7 kHz search coils). VDI Scale Objects From -90 to -86 hot rocks, incorrectly set up ground. From -86 to -70 small nails and other metal scrap. From -70 to -50 medium size wrought nails, small arrow heads. From -50 to -35 large wrought nails, medieval knives, flat arrow heads, horseshoes, locks and other fairly...
Page 19
Selective Metal Detector «Sorex» 7281. Operating manual AKA LLC+7(495)623-4026 621-0481 http://aka.2000.ru [email protected] 19 Discrimination Sector Setup. To setup required discrimination sector, press several times, select entry setup left discriminator border. You will see a VDI digit in the square frame above the left border of the discrimination sector. Use buttons and to change this number, moving the border to the left, increasing range of targets...
Page 20
Selective Metal Detector «Sorex» 7281. Operating manual AKA LLC+7(495)623-4026 621-0481 http://aka.2000.ru [email protected] 20 Static mode (Pin-Point) This mode is used basically as a secondary mode to clarify target location in the ground. After target detection in dynamic mode (primary search mode), put the coil slightly aside from the assumed target location and press . Warning! Avoid turning this mode on in the zone of target sensitivity (put the coil rather far...