Operating & Filter Replacement Directions Thank You for choosing an Airpura High Efficiency Air Purifier To bring you the benefits of clean indoor air To Begin Using Your Airpura... Inspect the exterior of your Airpura to verify there is no damage from shipping. If any damage is noted please follow the instructions in the Airpura returns policy. Wipe the unit with a damp cloth to remove any dust from packaging Plug the unit into a regular grounded 110 volt outlet Turn on the unit to MAX and allow it to run for a few minutes Set the variable speed control to the level you wish The most efficient way to use your Airpura for regular air quality maintenance is to run it at a low speed 24 hours a day 7 days a week Feel the difference breathing clean air makes to your health Replace the 4 screws and tighten Turn the Airpura back onto its casters Replace the gasket To close the filter chamber Position the indentation in the cover into the center of the HEPA filter P600 Open the filter chamber following the instructions on page 2 Pull the bulb and reflector together upward out of the connector Push the replacement bulb firmly into the connector Airpura limited warranty 5 years on parts and 10 years labor Details on line at www.airpura.com Replacing the UV Bulb and TitanClean Reflector TM Place the reflector around the bulb and replace the retaining screws Snip off the plastic retainer (for shipping only: does not need to be replaced) Unscrew the 2 retaining screws of the reflector Close the filter chamber following instructions on page 4
Filter Maintenance and Replacement The HEPA Filter The Activated Carbon Filter Can be vacuumed from the exterior of the unit once a month or more often. Should be replaced at least after 12 months of use Should be replaced at least every 3 to 5 years of normal use Remove the 4 retaining screws Take off the cover Let the spiral open to fill the opening Open the top of the spiral to make a slight funnel Insert the carbon canister into the funnel and hold it straight Let the canister slidedown the filter slider Pull the filter slider upout of the cavity using both hands and let the canister slide to the bottom of the cavity Remove the filterslider and fold it for further use Place a felt gasketat the bottom of the filter chamber Position the pre-filterinside the filter chamber