Page 11

                                                                      AIR CONDITIONER SERVICE MANUAL 412AC-210M 
Revision 7 Page 1 
CHAPTER 1 
INTRODUCTION 
1. SCOPE 
The scope of this manual encompasses the scheduled and unscheduled maintenance 
procedures for the continued airworthiness of the Air Comm Corporation air conditioning 
system installed in the Bell 412 series helicopter. 
 
2. PURPOSE 
The purpose of this manual is to provide the aircraft mechanic in the field the necessary 
information to...

Page 12

                                                                      AIR CONDITIONER SERVICE MANUAL 412AC-210M 
Revision 7 Page 2 
6. ABBREVIATIONS 
InHg:  Inches of Mercury 
Lbs:  Pounds 
Oz:  Ounces 
Psig:  Pounds per Square Inch (guage) 
gr:  Grams  
kg:  Kilograms 
Kg/Cm: Kilograms per Centimeter 
ml:  Milliliters 
mm:  Millimeters 
Nm                  Newton-meters 
 
7. PRECAUTIONS 
The following precautions are found throughout this manual, and will vary depending on 
the seriousness of the...

Page 13

                                                                      AIR CONDITIONER SERVICE MANUAL 412AC-210M 
Revision 7 Page 3 
11. DISTRIBUTION 
This  document is  to  be  placed  with  the  aircraft  maintenance  records  at  the  time  of 
system installation. 
Changes  will  be  made  to  this  document  in  response  to  “Safety  of  Flight”,  and  or  “Non-
safety of Flight” issues. Any changes will result in a revision to this document. Revisions 
shall be noted in the Record of Revisions...

Page 14

                                                                      AIR CONDITIONER SERVICE MANUAL 412AC-210M 
Revision 7 Page 4 
annunciator light (which shows on when the system is operating), the A/C & Blower 
on/off switch, and the Hi/Lo switches for the forward and aft evaporator blowers. 
 
 
 
Figure 1:  Cockpit A/C Control Panel 
 
The blower motors are two speed operation (Hi/Lo), and may be operated in conjunction 
with the A/C or Blower modes.  
 
The compressor is mounted on the aft side of...

Page 15

                                                                      AIR CONDITIONER SERVICE MANUAL 412AC-210M 
Revision 7 Page 5 
 
The system is also equipped with a Hi/Lo pressure switch. This switch is designed to 
protect the system against over-pressure situations, or in the event of refrigerant loss 
from the system. The switch also prevents the system from operating in low ambient 
temperatures below 50º F (10º C). 
  
The switch operating pressures are: 
 
Low Pressure Function: 
Cut-out at...

Page 16

                                                                      AIR CONDITIONER SERVICE MANUAL 412AC-210M 
Revision 7 Page 6 
15. REFRIGERATION CYCLE ILLUSTRATION 
 
NOTE: This illustration is provided as a reference only and may not match actual  
   installation 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
 
        High pressure liquid 
        High pressure vapor 
        Low pressure liquid 
        Low pressure vapor 
        Expansion valve        
         By pass line 
 
Figure 2:...

Page 17

                                                                      AIR CONDITIONER SERVICE MANUAL 412AC-210M 
Revision 7 Page 7 
CHAPTER 2 
AIRWORTHINESS LIMITATION SECTION 
 
 
1. AIRWORTHINESS LIMITATIONS 
 
The  Airworthiness  limitations  section  is  FAA  approved  and  specifies  inspections  and 
other  maintenance  required  under  Sections  43.16  and  91.403  of  Federal  Aviation 
Regulations unless an alternative program has been FAA approved. 
 
 No airworthiness limitations are...

Page 18

                                                                      AIR CONDITIONER SERVICE MANUAL 412AC-210M 
Revision 7 Page 8 
CHAPTER 3 
 INSPECTIONS   
1. INSPECTION REQUIREMENTS 
 
PERIODIC INSPECTIONS  
          (Hours are aircraft time)  
Item Prior to Cooling Season 
Every 25 Hours of Operation, +/- 3 hrs. 
Every 100 Hours of Operation, +/- 10 hrs. Special Inspection Information  
Evaporator Blower Hi/Lo Operation X  X Check for operation and security.  
Condenser Blower Motor & Fan Assy. X...

Page 19

                                                                      AIR CONDITIONER SERVICE MANUAL 412AC-210M 
Revision 7 Page 9 
3. INSPECTION PROCEDURES  
 
NOTE 
Refer to “Chapter 4 location and access” to locate all components for inspection. 
 
A. Inspection of the FWD and AFT evaporator blower motors 
 
CAUTION 
Fans are designed to operate with the resistance of the entire ducting system. 
Operation of the evaporator fans with any part of the distribution system removed may 
cause permanent...

Page 20

                                                                      AIR CONDITIONER SERVICE MANUAL 412AC-210M 
Revision 7 Page 10 
 
d. Place the A/C mode switch into the Off position and verify that the 
condenser fan is deactivated. 
e. Ensure that the jumper wire is removed from the binary switch. 
 
C. Inspection of compressor drive belt 
a. Remove transmission cowling to gain access to compressor drive 
belt and visually inspect the A/C compressor drive belt for the 
following: 
1. Any signs of...