Have a look at the manual Air Vent Inc. ShingleOver Filtered Ridge Vent Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 38 Air Vent Inc. manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
SHINGLEOVERFILTEREDRIDGEVENT Installation Instructions Fits roofs with 3/12 to 16/12 pitches. 1.On existing roofs, remove cap shingles. Mark slot width at both ends of ridge. Use slot guides imprinted on vent and refer to drawings below. Snap chalk line on both sides of ridge. 4.Prefasten first section using roofing nails through predrilled nail bosses. Continue to prefasten remaining sections, making sure support ribs are flat on the roof and filter is secure between shingles and vent.5.Use utility knife to cut final section to length. Final section should be oriented so that the inte grated end plug is flush with the end of the roof. Prefasten final section.6.Nail cap shingles in place using roofing nails long enough to penetrate roof sheathing. Use nailing lines provided on vent as guide. If using a nail gun, see #8 under important notes. 2.Cut slot (plumb cut, if possible). Note: Adjust depth of blade to avoid cutting rafters or trusses. Refer to drawings below for slot dimensions. Remove debris from slot. 3.Center vent over slot. End should be flush with end of roof. Make sure vent’s support ribs sit flat on the roof, and that filter is secure between shingles and vent. Hipand Gable Roofs Cut slot 3/4 on both sides of ridge centerline or from ridge board and to within 6 of end wall or hip intersection as illustrated in Figure 4. L and T Shaped Roofs Cut slot, as per Figure 5and run the ridge vent across long ridge. On short ridge, cut slot to within 12 of junction point and run the ridge vent from end of roof to butt against crossing the ridge vent. Chimneys Cut slots to within 12 of chimney. Run the ridge vent from end of roof to butt against chimney as shown in Figure6. Highest quality copolymerremains sturdy, nailable, and flexible,in all climates. Cap shingles install easily,makingthe vent virtually invisible. External wind bafflecreates low air pressure above the vent and helps pull air out of the attic. Built in end plug seals the end. High gloss nailing linesfor accurate, fast cap shingle nailing. Nail bosses, reinforced nail holes designed to prevent over nailing, located at 16 and 24 centers. Air slotshave 18 sq. inches free vent area per lineal foot. INSTRUCTIONS FOR CUTTING SLOTS 4117 Pinnacle Point Drive Suite 400, Dallas TX 75211 800AIRVENT (2478368) (See other side for additional installation instructions) IMPORTANT NOTES 1.When using standard flat 3 tab shingles, it is unnecessary to caulk under flange of the vent. 2.Caulk between low areas of shingle and flange of vent, making sure you don’t plug drain holes. 3.When applying vents to shakes, fold felt as shown in drawings on other side. 4.Before fastening vent, make sure filter is secured between shingles and vent. 5.When installing vent in cold weather, leave a 1/8 gap between vent sections to allow for expansion in hot weather. 6.See instructions below for cutting slot. 7.For best appearance, run the ridge vent from end to end to give the roof a more even, attractive appearance. 8.When using a nail gun to install cap shingles over the ridge vent, special care should be taken. It is important that the roofing nails penetrate the roof deck without compressing the ridge vent. Nails driven too deep will dimple or distort the cap shingles. Nails not driven deep enough may allow the ridge vent fasteners to back out of the roof deck and could result in blowoffs. NOTE:Air Vent’s written warranty for this product shall not apply in any instance in which the product was not installed in accordance with the instructions contained herein. indicates slot widthindicates vent runindicates end wall Reinforced ribsfor greater stability and rigidity. Imprinted slot guidesfor proper slot opening and alignment.Internal weatherfiltermade of untreated, unwoven fiberglass to protect from weather infiltration. 6 from end wall to slot6 from end wall to slot6 from end wall to slot 6 121212 slot widthEnd wall End wall End wall End wall Fig. 6 Run the ridge vent to end of ridge Hip endFig. 4Gable endFig. 5 Run the ridge vent to end of ridge End wallEnd wall 6 from end wall to slot 6 from end wall to slot
SHINGLEOVERFILTEREDRIDGEVENT Installation Instructions Fits roofs with 3/12 to 16/12 pitches.S ee below for special conditions of steep pitch r oofs and truss type construction. Thanks for choosing ShingleOver Filtered Ridge Vent! This product is engineered to provide the best, most efficient ventilation system available. When properlyi nstalled, ShingleOver Filtered Ridge Vent will: • Help prevent the premature deterioration of shingles and other roofing materials caused by inadequate ventilation. • Meet typical roof shingle warranty ventilation requirements. • Help prevent attic heat buildup and ice dams by continuously moving air along underside of roof deck. For best results install adequate intake vents ShingleOver Filtered Ridge Vent is designed to exhaust moistureladen air from the attic. To achieve optimum ventilation efficiency, existing roof vents, turbine vents and gable vents should be removed or plugged, and intake ventilation must be installed at the soffit or eave. Products such as Air Vent’s Continuous Soffit Vent, Vented Drip Edge or Undereave Vent provide the necessary intake v entilation for optimum performance provided the intake net free area matches or exceeds the exhaust net free area. ShingleOver Filtered Ridge Vent is asnap to install! Just follow these simple instructions. If you have any questions or require special installation assistance, call our tollfree number from 8 a.m. 5 p.m. (C.S.T.) Mon. Fri.: 1800AIRVENT (2478368) Tools needed for installation •Hammer •Utility knife •Chalk line •Roofing nails •Tape measure •Circular saw What and Who is Covered and for How LongProvided that the ridge vent has been installed in strict accordance with Air Vent Inc.’s (Air Vent) written installation instructions, Air Vent warrants that its ridge vent will be free from manufacturing defects for 30 (thirty) years from the date of purchase. Should any manufacturing defect occur during the 30year period following date of purchase, Air Vent will provide replacement material for that portion of the product deemed to be defective (not including labor costs incurred in removing defective vent or installing replacement product.) In the event of replacement according to the terms of this warranty, the original warranty shall apply to the replace ment material and will extend for the balance of the original warranty period in effect at the time the vent proved defective. Replacement Plus™ Protection Air Vent ridge ventilation products are covered by Replacement Plus™ protection for a period of 5 (five) years, provid ed that theridge vent has been installed in strict accordance with Air Vents written installation instructions. Under this warranty feature, Air Vent, at no charge, will replace any ridge vent found to be defective during the Replacement Plus™ period (the Replacement Plus™ period begins when the ridge vent application is completed). Air Vents maximum liability under Replacement Plus™ will be equal to the reasonable cost to replace the defec tive ridge vent, including labor. In instances in which Air Vent, according to the terms of this warranty, has agreed to pay the cost of labor required to replace a defective ridge vent, Air Vent will provide reimbursement only upon receipt of a copy of the contractors invoice or other written evidence of the completion of the work which Air Vent, at its sole discretion, deems acceptable. TransferabilityIf there is a change in ownership, the warranty may be transferred by the original purchaser of the ridge vent to the new owner under the terms and conditions of this warranty. The warranty will then cover the period of 30 years following the purchase of the ridge vent. If the warranty is transferred from the original purchaser to a new owner during the 5 (five) year Replacement Plus™ period, the remaining period of Replacement Plus™ will be available to the subsequent property owner. At the end of the Replacement Plus™ period, the warranty will cover 25 years following the purchase of the ridge vent. LimitationsAir Vent shall not be liable for, and this warranty does not apply to, any failure, defect or damage resulting from or connected with misuse, abuse, neglect or improper handling or storage, or installation not in strict adherence to Air Vents written instructions; impact or foreign objects, fire, flood, earthquake, lightning, hurricane, hail, tornado or other violent storms or other act of God; or defects in, failure of or damage caused by materials used as a roofing base over which the vent is installed or by movement, distortion, cracking or setting of walls or the foundation of the building. Air Vent reserves the right to discontinue or modify any of its products, including color, and shall not be liable as a result of such discontinuance or modification, nor shall Air Vent be liable in the event replacement material may vary in color in comparison to the original product as a result of normal weathering. If Air Vent replaces any material under this warranty,it may substitute products designated by Air Vent to be of comparable quality or price range in the event the product initially installed has been discontinued or modified. Other ConsiderationsTHIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER ORAL OR WRITTEN WARRANTIES, LIABILITIES OR OBLIGATIONS OF AIR VENT. PERTINENT STATE LAW SHALL CONTROL FOR WHAT PERIOD OF TIME SUBSEQUENT TO SALE A CONSUMER HOME OWNER MAY SEEK A REMEDY PURSUANT TO THE IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL AIR VENT BE LIABLE FOR CONSE QUENTIAL OR INCIDENTAL DAMAGES OF ANY KIND, INCLUDING ANY DAMAGE TO THE BUILDING, ITS CONTENTS OR ANY PERSONS THEREIN, RESULTING FROM THE BREACH OF ANY WARRANTY SET FORTH HEREIN. NO FIELD REPRESENTATIVE OF AIR VENT OR ANY DISTRIBUTOR OR DEAL ER IS AUTHORIZED TO MAKE ANY CHANGE OR MODIFICATION TO THIS WARRANTY. SOME STATES DO NOT ALLOW LIMITATIONS ON OR THE EXCLU SION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE EXCLUSIONS MAYNOT APPLY TO YOU. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. 30YEARLIMITEDWARRANTY Limited, nonprorated and transferable What the Customer Must DoTo obtain performance under this warranty, the homeowner/consumer must notify Air Vent in writing of any manufacturing defect promptly following its discovery,and shall submit with such notification proof of date of purchase and vent installation, in order to provide Air Vent an opportunity to investigate the claim and examine the material claimed to be defective. All notifications shall be provided to: Air Vent Inc. 7700 Harker Drive, Peoria, Illinois 61615. Air Vent shall then promptly inspect the claimed defect before the furnishing of any replacement vent is approved, and Air Vent shall, within a reasonable time after approval, provide a replacement vent (or vents) under the terms of the warranty. This warranty is effective on ridge vents applied on or after September 1, 2008. PLEASE COMPLETE THIS FORM AND RETAIN WITH YOUR IMPORTANT PAPERS Date installed _______________________________________________________________________ Installed by _________________________________________________________________________ Address ____________________________________________________________________________ City ________________________________________________________________________________ State ____________________________________________________ Zip ______________________ Property owner _____________________________________________________________________ Property address ____________________________________________________________________ City ________________________________________________________________________________ State ____________________________________________________ Zip ______________________ 4117 Pinnacle Point Drive, Suite 400 Dallas TX 75211 Fig. 3TRUSS TYPE CONSTRUCTIONFig. 2 STEEP PITCH ROOF (16/12) F ig. 1R IDGE BOARD TYPE CONSTRUCTION (See other side for additional installation instructions) 1 31/8 ”(SV II) 10 3/4 ”(SVII 9) 91/2 ”(SV II 7) RIDGE B OARDRIDGE VENT FILTER CAP SHINGL ES RO OFI NG NAILS AIR SLO TS DRAIN SL OTS 11/2” 1” 6 12 RAFTERRAFTER Cut outsl ot for existin groof const ruction, le ave gap for new roof co nstruction 3/4 ” 3/4” 3” Do not le tcap shingl eover hang edge of air slot FELT Return roo fingfelt for new roo fco nstr uction o ruse co ntinuo us sealan tbead for existing ro of con structi on TRUSS TRUSS 11/2” 3/4” 3”3/4 ”CAUTI ON: on steep pit ch roof condit ions verify p rope r clearance fromedge of sheathing pri or to nailing 13 1/8 ”(SV II) 1 0 3/4 ”(SVII 9) 9 1/2 ”(SV II 7) RIDGE B OARDR IDGE VENT FILTER C AP SHI NGL ES ROOFI NG N AILS AIR SLO TS DRAIN SL OTS 11/2” 1” 6 12 RAFTERRAFTER C ut outsl ot for existin groof const ruction, le ave gap for new roof co nstruction 3/4” 3/4” 3” Do not le tcap shingl eover hang e dge of air slot F ELT R eturn roo fingfelt for new roo fco nstr uction oruse co ntinuo us sealan tbead for existing ro of con structi on