    Have a look at the manual Air Vent Inc. ShingleOver Filtered Ridge Vent Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 38 Air Vent Inc. manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							SHINGLEOVERFILTEREDRIDGEVENT
    Installation Instructions
    Fits roofs with 3/12 to 16/12 pitches.
    1.On existing roofs, remove cap shingles. Mark
    slot width at both ends of ridge. Use slot guides
    imprinted on vent and refer to drawings below.
    Snap chalk line on both sides of ridge.
    4.Prefasten first section using roofing nails
    through predrilled nail bosses. Continue to 
    prefasten remaining sections, making sure 
    support ribs are flat on the roof and filter is
    secure between shingles and vent.5.Use utility knife to cut final section to length.
    Final section should be oriented so that the inte
    grated end plug is flush with the end of the roof.
    Prefasten final section.6.Nail cap shingles in place using roofing 
    nails long enough to penetrate roof sheathing. 
    Use nailing lines provided on vent as guide. If
    using a nail gun, see #8 under important notes.
    2.Cut slot (plumb cut, if possible). Note: Adjust
    depth of blade to avoid cutting rafters or trusses.
    Refer to drawings below for slot dimensions.
    Remove debris from slot.
    3.Center vent over slot. End should be flush
    with end of roof. Make sure vent’s support ribs 
    sit flat on the roof, and that filter is secure
    between shingles and vent.
    Hipand Gable Roofs
    Cut slot 3/4 on both sides of ridge centerline
    or from ridge board and to within 6 of end
    wall or hip intersection as illustrated in 
    Figure 4.
    L and T Shaped Roofs
    Cut slot, as per Figure 5and run the ridge vent 
    across long ridge. On short ridge, cut slot to within
    12 of junction point and run the ridge vent from 
    end of roof to butt against crossing the ridge vent.
    Chimneys
    Cut slots to within 12 of chimney. 
    Run the ridge vent from end of roof to butt 
    against chimney as shown in 
    Figure6.
    Highest quality copolymerremains sturdy,
    nailable, and flexible,in all climates.
    Cap shingles install easily,makingthe vent 
    virtually invisible.
    External wind bafflecreates low 
    air pressure above the vent and helps 
    pull air out of the attic.
    Built in end plug seals the end.
    High gloss nailing linesfor accurate, 
    fast cap shingle nailing.
    Nail bosses, reinforced nail holes 
    designed to prevent over nailing, 
    located at 16 and 24 centers.
    Air slotshave 18 sq. inches free vent area
    per lineal foot.
    INSTRUCTIONS FOR CUTTING SLOTS
    4117 Pinnacle Point Drive
    Suite 400, Dallas TX  75211
    800AIRVENT (2478368)
    (See other side for additional installation instructions)
    IMPORTANT NOTES 
    1.When using standard flat 3 tab shingles, it is unnecessary to caulk under flange of the vent.
    2.Caulk between low areas of shingle and flange of vent, making sure you don’t plug drain holes.
    3.When applying vents to shakes, fold felt as shown in drawings on other side.
    4.Before fastening vent, make sure filter is secured between shingles and vent.
    5.When installing vent in cold weather, leave a 1/8 gap between vent sections to allow for expansion in hot weather.
    6.See instructions below for cutting slot.
    7.For best appearance, run the ridge vent from end to end to give the roof a more even, attractive appearance.
    8.When using a nail gun to install cap shingles over the ridge vent, special care should be taken. It is important that the roofing 
    nails penetrate the roof deck without compressing the ridge vent. Nails driven too deep will dimple or distort the cap shingles. 
    Nails not driven deep enough may allow the ridge vent fasteners to back out of the roof deck and could result in blowoffs.
    NOTE:Air Vent’s written warranty for this product shall not apply in any instance in which the product was not installed in accordance with the instructions contained herein.
    indicates slot widthindicates vent runindicates end wall
    Reinforced ribsfor greater
    stability and rigidity.
    Imprinted slot guidesfor proper
    slot opening and alignment.Internal weatherfiltermade of 
    untreated, unwoven fiberglass
    to protect from weather
    infiltration.
    6 from 
    end wall
    to slot6 from 
    end wall
    to slot6 from 
    end wall 
    to slot
    6
    121212 slot widthEnd wall
    End wall End wall
    End wall
    Fig. 6
    Run the ridge vent
    to end of ridge
    Hip endFig. 4Gable endFig. 5
    Run the ridge vent to
    end of ridge
    End wallEnd wall 6 from 
    end wall 
    to slot
    6 from 
    end wall 
    to slot
                                  
    						
    							SHINGLEOVERFILTEREDRIDGEVENT
    Installation Instructions
    Fits roofs with 3/12 to 16/12 pitches.S
    ee below for special conditions of steep pitch 
    r
    oofs and truss type construction.
    Thanks for choosing ShingleOver
    Filtered Ridge Vent!
    This product is engineered to provide the best, most 
    efficient ventilation system available. When properlyi
    nstalled, ShingleOver Filtered Ridge Vent will:
    • Help prevent the premature deterioration of shingles and 
    other roofing materials caused by inadequate ventilation.
    • Meet typical roof shingle warranty ventilation requirements.
    • Help prevent attic heat buildup and ice dams by 
    continuously moving air along underside of roof deck.
    For best results install adequate
    intake vents
    ShingleOver Filtered Ridge Vent is designed to exhaust
    moistureladen air from the attic. To achieve optimum 
    ventilation efficiency, existing roof vents, turbine vents 
    and gable vents should be removed or plugged, and intake
    ventilation must be installed at the soffit or eave. Products
    such as Air Vent’s Continuous Soffit Vent, Vented Drip
    Edge or Undereave Vent provide the necessary intake 
    v
    entilation for optimum performance provided the intake 
    net free area matches or exceeds the exhaust net free area.
    ShingleOver Filtered Ridge Vent is 
    asnap to install!
    Just follow these simple instructions. If you have any 
    questions or require special installation assistance, call 
    our tollfree number from 8 a.m.  5 p.m. (C.S.T.)
    Mon.  Fri.: 1800AIRVENT (2478368)
    Tools needed 
    for installation
    •Hammer
    •Utility knife
    •Chalk line
    •Roofing nails
    •Tape measure
    •Circular saw
    What and Who is Covered and for How LongProvided that the ridge vent has been installed in strict accordance with Air Vent Inc.’s (Air Vent) written installation
    instructions, Air Vent warrants that its ridge vent will be free from manufacturing defects for 30 (thirty) years from
    the date of purchase.
    Should any manufacturing defect occur during the 30year period following date of purchase, Air Vent will provide
    replacement material for that portion of the product deemed to be defective (not including labor costs incurred in
    removing defective vent or installing replacement product.)
    In the event of replacement according to the terms of this warranty, the original warranty shall apply to the replace
    ment material and will extend for the balance of the original warranty period in effect at the time the vent proved
    defective.
    Replacement Plus™ Protection  Air Vent ridge ventilation products are covered by Replacement Plus™ protection for a period of 5 (five) years, provid
    ed that theridge vent has been installed in strict accordance with Air Vents written installation instructions. Under
    this warranty feature, Air Vent, at no charge, will replace any ridge vent found to be defective during the
    Replacement Plus™ period (the Replacement Plus™ period begins when the ridge vent application is completed).
    Air Vents maximum liability under Replacement Plus™ will be equal to the reasonable cost to replace the defec
    tive ridge vent, including labor.
    In instances in which Air Vent, according to the terms of this warranty, has agreed to pay the cost of labor required to
    replace a defective ridge vent, Air Vent will provide reimbursement only upon receipt of a copy of the contractors
    invoice or other written evidence of the completion of the work which Air Vent, at its sole discretion, deems acceptable.
    TransferabilityIf there is a change in ownership, the warranty may be transferred by the original purchaser of the ridge vent to the
    new owner under the terms and conditions of this warranty. The warranty will then cover the period of 30 years 
    following the purchase of the ridge vent.
    If the warranty is transferred from the original purchaser to a new owner during the 5 (five) year Replacement Plus™
    period, the remaining period of Replacement Plus™ will be available to the subsequent property owner. At the end
    of the Replacement Plus™ period, the warranty will cover 25 years following the purchase of the ridge vent.
    LimitationsAir Vent shall not be liable for, and this warranty does not apply to, any failure, defect or damage resulting from or
    connected with misuse, abuse, neglect or improper handling or storage, or installation not in strict adherence to Air
    Vents written instructions; impact or foreign objects, fire, flood, earthquake, lightning, hurricane, hail, tornado or
    other violent storms or other act of God; or defects in, failure of or damage caused by materials used as a roofing
    base over which the vent is installed or by movement, distortion, cracking or setting of walls or the foundation of 
    the building.
    Air Vent reserves the right to discontinue or modify any of its products, including color, and shall not be liable as a
    result of such discontinuance or modification, nor shall Air Vent be liable in the event replacement material may vary
    in color in comparison to the original product as a result of normal weathering. If Air Vent replaces any material
    under this warranty,it may substitute products designated by Air Vent to be of comparable quality or price range in
    the event the product initially installed has been discontinued or modified.
    Other ConsiderationsTHIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER ORAL OR WRITTEN WARRANTIES, LIABILITIES OR OBLIGATIONS OF AIR VENT. PERTINENT
    STATE LAW SHALL CONTROL FOR WHAT PERIOD OF TIME SUBSEQUENT TO SALE A CONSUMER HOME OWNER MAY SEEK A REMEDY PURSUANT TO
    THE IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL AIR VENT BE LIABLE FOR CONSE
    QUENTIAL OR INCIDENTAL DAMAGES OF ANY KIND, INCLUDING ANY DAMAGE TO THE BUILDING, ITS CONTENTS OR ANY PERSONS THEREIN,
    RESULTING FROM THE BREACH OF ANY WARRANTY SET FORTH HEREIN. NO FIELD REPRESENTATIVE OF AIR VENT OR ANY DISTRIBUTOR OR DEAL
    ER IS AUTHORIZED TO MAKE ANY CHANGE OR MODIFICATION TO THIS WARRANTY. SOME STATES DO NOT ALLOW LIMITATIONS ON OR THE EXCLU
    SION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE EXCLUSIONS MAYNOT APPLY TO YOU.
    This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
    30YEARLIMITEDWARRANTY
    Limited, nonprorated and transferable
    What the Customer Must DoTo obtain performance under this warranty, the homeowner/consumer must notify Air Vent in writing of any 
    manufacturing defect promptly following its discovery,and shall submit with such notification proof of date of 
    purchase and vent installation, in order to provide Air Vent an opportunity to investigate the claim and examine the
    material claimed to be defective. All notifications shall be provided to: Air Vent Inc. 7700 Harker Drive, Peoria, Illinois
    61615. Air Vent shall then promptly inspect the claimed defect before the furnishing of any replacement vent is
    approved, and Air Vent shall, within a reasonable time after approval, provide a replacement vent (or vents) under the
    terms of the warranty. This warranty is effective on ridge vents applied on or after September 1, 2008.
    PLEASE COMPLETE THIS FORM AND RETAIN WITH YOUR IMPORTANT PAPERS
    Date installed _______________________________________________________________________
    Installed by _________________________________________________________________________
    Address ____________________________________________________________________________
    City ________________________________________________________________________________
    State  ____________________________________________________ Zip ______________________
    Property owner _____________________________________________________________________
    Property address ____________________________________________________________________
    City ________________________________________________________________________________
    State  ____________________________________________________ Zip ______________________
    4117 Pinnacle Point Drive, Suite 400 
    Dallas TX  75211
    Fig. 3TRUSS TYPE CONSTRUCTIONFig. 2 STEEP PITCH ROOF (16/12)
    F
    ig. 1R
    IDGE BOARD TYPE CONSTRUCTION
    (See other side for additional installation instructions)  1
    31/8 ”(SV II)
    10  3/4 ”(SVII 9)
     
    91/2 ”(SV II 7)
    RIDGE B OARDRIDGE VENT
    FILTER
    CAP SHINGL ES
    RO OFI NG
    NAILS
    AIR SLO TS
    DRAIN SL OTS 11/2”
    1”
    6
    12
    RAFTERRAFTER
    Cut outsl ot  for  existin groof
    const ruction, le ave gap for
    new roof co nstruction 3/4 ”
    3/4”
    3” Do not le tcap
    shingl eover hang
    edge  of air slot
    FELT
    Return roo fingfelt  for new roo fco nstr uction
    o
    ruse co ntinuo us sealan tbead  for existing
    ro of  con structi on  TRUSS
    TRUSS
    11/2”  3/4”
    3”3/4 ”CAUTI ON:  on  steep pit ch
    roof  condit ions verify p rope r
    clearance  fromedge of
    sheathing pri or to nailing  13 1/8 ”(SV II)
    1
    0 3/4 ”(SVII 9)
     9 1/2 ”(SV II 7)
    RIDGE B OARDR
    IDGE VENT
    FILTER
    C
    AP SHI NGL ES
    ROOFI NG
    N
    AILS
    AIR SLO TS
    DRAIN SL OTS 11/2”
    1”
    6
    12
    RAFTERRAFTER
    C
    ut outsl ot  for  existin groof
    const ruction, le ave gap for
    new roof co nstruction 3/4”
    3/4”
    3” Do not le tcap
    shingl eover hang
    e
    dge  of air slot
    F
    ELT
    R
    eturn roo fingfelt  for new roo fco nstr uction
    oruse co ntinuo us sealan tbead  for existing
    ro of  con structi on   
    						