Air Vent Inc. Roof Mount Attic Fan Installation Instructions
Have a look at the manual Air Vent Inc. Roof Mount Attic Fan Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 38 Air Vent Inc. manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
WARNING: Read all warning messages and instructions before starting installation of this fan. Failure to follow these safety instructions can result in injury or even death. If you need assistance in understanding these instructions or have questions or comments, please call 1 (309) 692-6969. ELECTRICAL HAZARDS DANGER: The electrical installation and wiring of this fan must be done by a qualified electrician in accordance with all local codes and standards, including fire-rated construc- tion. Failure to do the installation properly can result in fire or even death. NOTE: A few hours of operation without appar - ent problems does not necessarily imply that the installation is safe. DANGER: Do not substitute a solid state speed control for the thermostatically controlled on-off switch that comes with this fan. Use of a solid state speed control can result in a fire causing injury or death. DANGER: Watch out for existing electrical wiring and other utility wires or pipes when selecting a location for the fan. Do not install the fan where there is electrical wiring in the way. Select another location or have a qualified electrician move the wiring to a different location. DANGER: Before servicing or cleaning unit, switch power off at the service panel and lock service panel to prevent power from being switched on accidentally. When the ser - vice disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel. LACERATION HAZARDS DANGER: This fan has an unguarded fan blade. Do not use in locations which are readily accessible to people or ani- mals. Do not let children play in an attic where this fan has been installed. Contact with this fan while in operation can result in injury or even death. DANGER: Switch the power off at the service panel and lock the service panel before servicing the motor. When the ser - vice disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel. This fan is thermostatically controlled - it may start at any time if the power is not switched off at the service panel. Contact with the fan blades while the fan is operating can result in serious injury. W ARNING: This product has sharp metal edges that can cut your hands. Wear canvas work gloves while handling the fan during installation. OTHER HAZARDS D ANGER: For general ventilating use only. Do not use to exhaust hazardous or explosive materials or vapors. Use of this fan to exhaust hazardous, explosive or flammable materials may result in a fire or explosion, causing injury or death. PRECAUCIÓN: Lea todos las instrucciónes y advertencias, antes de empezar a instalar este ventilador. El caso omiso de estas instrucciónes, puede ocasiónarle lesiónes graves o inclusive hasta la muerte. Si usted necesita ayuda para com prender estas instrucciónes, tiene preguntas o comentarios, favor de llamar al: 1 (309) 6926969. RIESGOS ELECTRICOS PELIGRO: La instalación electrica y el alambrado de este ventilador debera ser hecho por una electricista cualificado de acuerdo con todos códigos y las normas locales, incluy endo normas de fuego para la construcción. El caso omiso de una instalación apropiada puede provocar fuego o inclu sive hasta la muerte. NOTA: Unas pocas horas con el venti lador operando sin problemas aparentes no significa que la instalación sea segura. PELIGRO: No substituya el control termostático de interrup tor que controla el encendido y apagado que viene con este ventilador. Usar de cualquier otro control puede provocar fuego causando heridas o hasta la muerte. PELIGRO: Tenga cuidado con las instalaciónes electricas ya existentes o cualquier otra instalación o tuberías cuando elija el lugar apropiado para su ventilador. No instale el venti lador donde haya alambres o cables que le puedan estorbar. Elija otro lugar o consulte con un electricista cualificado para hacer un movimiento de instalación electrica adecuada hacia otro lugar. PELIGRO: Antes de hacer servicio o limpieza a la unidad, cerciórese de cortar la corriente de la caja de registro eléc trico y asegúrela para prevenir que se haga una conexión imprevista. Si es imposible asegurar la caja de registro eléc trico, amarre seguramente un aviso del peligro tal como una etiqueta a la caja. RIESGOS DE LACERACIÓN PELIGRO: Este ventilador tiene unas aspas peligrosas de metal sin protección. No coloque en lugares al alcance de las personas o animales. No permita que los niños jueguen en el ático cuando el ventilador haya sido instalado. El con tacto con este ventilador cuando esté en funcionamiento puede provocar daños graves o inclusive hasta la muerte. PELIGRO: Ceriórese de cortar la corriente de la caja de registro eléctrico y asegúrela, antes de empezar a trabajar en la banda del motor o el motor. El contacto con la banda del ventilador mientras esté funcionando puede ocasionarle heridas graves. Esto también le puede atraer hacia las aspas provocando daños más graves o inclusive hasta la muerte. PRECAUCIÓN: Este producto tiene bordes muy afilados que podrían cortarle las manos. Use guantes de lona mien tras usted esté instalado el ventilador. OTROS RIESGOS PELIGRO: Uso exclusivo para ventilación general. No use este producto para extraer gases peligrosos, materiales explosivos u otros vapores. Installation Instructions Roof Mounted Power Attic Ventilator Ventilador de Poder Del Ático Montado en el Techo Important Safety Information Información Importante Para Su Seguridad Part No. 18370
ROOF MOUNTED POWER ATTIC VENTILATOR INSTALLATION INSTRUCTIONS NOTE: Air intake openings are necessary for proper exhaust operation. Best results will be obtained if these openings are located around the eaves. Undereave soffit grills or continuous soffit vents are suggested. Sq. Ft. of Air Intake Model Opening Needed RV26 3.9 RV28 4.4 TOOLS NEEDED : Electric drill, tape measure, hammer & nails, utility knife and pencil, jig or sabre saw, roofing nails, phillips screw driver, adjustable wrench, wire cutter, work gloves and safety glasses. VENTILADOR DE PODER DEL ÁTICO MONTADO EN EL TECHO INSTRUCCIÓNES PARA LA INSTALACIÓN NOTA: Aberturas para la toma de aire son necesarias para una apropiada operación. Se obtendrán mejores resultados si estas aberturas están localizadas alrededor de los aleros. Se sugiere el uso de rejiillas de sofito bajo alero o ventilas continuas de sofito. Pies cuadrados (metros cuadrados) de abertura Modelo para toma de aire abertura necesaria. RV26 3.9 RV28 4.4 HERRAMIENTAS REQUERIDAS PARA INSTALACION: Taladro, cinta de medir o regla, martillo, clavos para techo, navaja, lapiz, serrucho, destornillador llave, tijeras, lentes de seguridad y guantes de uso rudo. 1. POSITIONING THE POWER ATTIC VENTILATOR ON THE ROOF: Set the unit approximately in the center of the roof close to the ridgeline. Position the ventilator so that the unit can only be seen from one side of the house. 1. ACOMODANDO EL VENTILADOR DE PODER EN EL TECHO: Acomode la unidad aproximadamente en el centro del techo cerca del madero horizontal superior. Acomode la unidad de tal manera que solo se pueda ver de un lado de la casa. 2. DRILL THE GUIDE HOLE: Measure the distance to the ridgeline and to one end of the roof. Transfer these exterior dimensions to inside the attic. Next locate a cen- ter position between two rafters (inside the attic) as near as possible to the outside measurements. Drill a guide hole through the roof from inside that is equal distance from the two rafters. Place a marker through the roof for quick identification while on the roof. 2. HAGA EL AGUJERO GUÍA: Mida la distancia del madero horizontal superior hasta el punto final del techo. Traslade las medidas exteriores a la parte interna del ático. Despues localice una posición centrada entre 2 vigas (dentro del ático) lo mas cerca posible de las dimensiónes exteriores. Haga un agujero guía en el techo. Ponga una marca en el techo para una identifi cación más rapida mientras esté en el techo. 3. CUTTING THE HOLE: Draw a circle 14 1/2´´ in diameter using the guidehole as the center. A template is provided on the back of the carton for drawing the circle. 3. PARA HACER EL AGUJERO: Dibuje un círculo de 14 1/2 pulgadas de di·metro usando el agujeroguía como el centro. El patrón viene incluido en la parte trasera de la caja de carton, para dibujar el círculo. 4. CUTTING THE HOLE IN THE ROOF . Using a sabre saw, cut and remove all roof shingles (and deck) inside the 14 1/2´ ´ diameter circle. Next cut an extra 1 inch off the top half of the hole (shingles only) to allow room for placing and positioning the flange. Do not cut through any rafters. Cutting a rafter may cause your roof to sag. 1.) 2.) 3.)
4. PARA CORTAR EL AGUJERO EN EL TECHO: Usando una sierra caladora, corte y remueva las tejas (y la made ra) que este adentro del círculo de 14 1/2 pulgadas de diámetro. Después corte 1 pulgada más en la parte de arriba del agujero (solo la teja) para dar espacio y acomo dar la corona. No corte ningúna viga. El cortar una viga puede causar que su techo se hunda. 5. SECURING THE BASE: Make sure the base flange parallels the ridgeline of the roof. The embossed arrow and word UP should be pointing towards the ridgeline. Slip the upper half of the flange under the shingles. Center unit over the hole. Attach flange securely to roof using roofing nails around the perimeter of the unit (Underneath shingles at the top). A nonhardening caulk can be used to seal between the flange and shingles. 5. PARA ASEGURAR LA BASE: Cerciórese de que la base de la corona esté paralela con la del madero hor izontal superior del techo. Las flechas realizadas y la palabra “UP” deben estar apuntado hacia el madero horizontal superior. Deslice la parte superior de la corona debajo de las tejas. Centre la unidad sobre el agujero. Junte la corona seguramente al techo usando clavos para techo alrede dor del perímetro de la unidad (debajo de las tejas supe riores). Una goma suave puede ser usada para sellar la corona con la teja. 6. INSTALLING THE THERMOSTAT: Inside the attic, separate the thermostat cover from the mounting plate. Secure the plate to a rafter. See step 7 to connect the thermostat. 6. PARA INSTALAR EL TERMOSTATO: Dentro del ático, separe la cubierta del termostato de la base de montaje. Asegure la base a una viga. Vea el paso 7 para conectar el termostato. 7. WIRING THE THERMOSTAT: DANGER: The electrical installation and wiring of this fan must be done by a qualified electrician in accordance with all local codes and standards, including fire-rated construction. Failure to do the installation properly can result in fire or even death. NOTE: A few hours of oper - ation without apparent problems does not necessarily imply that the installation is safe. DANGER: Do not substitute a solid state speed control for the thermostatically controlled on-off switch that comes with this fan. Use of a solid state speed control can result in a fire causing injury or death. D ANGER: Make sure the circuit breaker powering the circuit on which the fan will operate is turned OFF before wiring the thermostat. You can be shocked or electrocut- ed if the breaker is not off. Wire the thermostat as shown in diagram 7. Attach your ground wire to the thermostat box. 7. ALAMBRANDO DEL TERMOSTATO: PELIGRO: La instalación eléctrica y el alambrado de este ventilador deberá ser hecho por una electricista capac itado de acuerdo con todos códigos y normas locales, incluyendo normas contra incendios en la construcción. El caso omiso de una instalación apropiada puede provo car incendios o inclusive la muerte. NOTA: Unas pocas horas con el ventilador operando sin problemas apar entes no significa que la instalación sea segura. PELIGRO: No substituya con un control de velocidades transistorizado el control termostático del interruptor que controla el encendido y apagado que viene con este ven tilador. El uso de cualquier otro control puede provocar incendios, causando heridas o aún la muerte. 5.) 6.) 4.)
PELIGRO: Cerciórese de que el circuito de poder que va alimentar el circuito del ventilador este APAGADO antes de conectar el termostato. Podría usted recibir una des carga eléctrica o resultar electrocutado si la corriente no está apagada. Conecte el termostato como muestra en el diagrama 7. Conecte el alambre de tierra a la caja del termostato. 8. THERMOSTAT OPERATION: The thermostat operates on a temperature setting. Set the temperature dial to a 100-110°F setting. When the power ventilator is opera- tional, the fan should start automatically when the attic temperature rises above the preset setting and cut off when the attic is cooled down to the thermostat setting. DANGER: Switch the power off at the service panel and lock the service panel before servicing the motor. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel. This fan is thermostatically controlled - it may start at any time if the power is not switched off at the service panel. Contact with the fan blades while the fan is operating can result in serious injury. 8. OPERACIÓN DEL TERMOSTATO: El termostato fun ciona según la temperatura indicada. Ajuste el marcador a una posición de 100 110° F. Cuando el ventilador de poder esté listo para operar, empezará a trabajar automáticamente cuando la temperatura del desván suba de la posición marcada y se apagara cuando la tempera tura en el desván sea menos que la posición indicada en al termostato. PELIGRO: Cerciórese de cortar la corriente de la caja de registro eléctrico y asegúrela, antes de empezar a trabajar en el motor. Si es imposible asegurar la caja de registro eléctrico, amarre seguramente un aviso del peligro tal como una etiqueta a la caja. Este ventilador está contro lado por un termostato que lo puede hacer funcionar en cualquier momento si el interruptor no está apagado en la caja de registro eléctrico. El contacto con las aspas de este ventilador cuando el ventilador esté operando puede provocar daños serios. LIMITED WARRANTY Model RV28 is warranted for ten years and Model RV26 is war - ranted for five years from date of purchase against defects in workmanship and materials. This warranty covers fan blade, motor, thermostat and housing. If you believe any part is defec- tive, call 1-800-527-1924 for Customer Service. If it’s determined that parts need to be returned, they must be shipped freight pre- paid to Air Vent, 4117 Pinnacle Point Drive, Suite 400, Dallas, TX 75211. If found to be defective following examination by Air Vent, any defective part will be replaced free of charge and returned freight prepaid. This warranty does not cover any labor costs, including those required for field repair or replacement or removal of any allegedly defective part. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. REPLACEMENT PLUS PROTECTION The Air Vent product to which this warranty applies is covered by Replacement Plus protection for a period of five (5) years (Model RV28) or two (2) years (Model RV26), provided that the product has been installed in strict accordance with Air Vent’s written installation instructions and in accordance with all local codes and standards, including those pertaining to fire-rated construction. Under this warranty feature, Air Vent, at no charge, will replace any part covered by this warranty and found to be defective during the Replacement Plus period (the Replacement Plus period begins when the power vent installation is complet- ed.) Air Vent’s maximum liability under Replacement Plus will be equal to the reasonable cost of the replacement part, including labor to remove the defective part and install the replacement part. In instances in which Air Vent, according to the terms of this warranty, has agreed to pay the cost of labor required to replace a defective part, Air Vent will provide reimbursement only upon receipt of a copy of the contractor’s invoice or other written evidence of the completion of the work which Air Vent, at its sole discretion, deems acceptable. LÍMITE GARANTÍA Modelo RV28 está garantizado por 10 años y Modelo RV26 está garantizado por 5 años desde la fecha de su compra, contra defectos de manufactura y materiales. Esta garantía cubre las aspas, el motor, el termostato, y la cubierta de metal. Si usted considera que alguna pieza es defectuosa, llame al Departamento de Servicio al Cliente, 1 800 527 1924. Si se determina que las piezas deben ser devueltas a Air Vent, envíelas con porte postal prepagado a Air Vent, 4117 Pinnacle Point Drive, Suite 400, Dallas, TX 75211. Si encontramos defec tos bajo el examen de Air Vent, Inc., cualquier parte será reemplazada sin costo alguno y le devolveremos el dinero de su flete. Esta garantía no cubre ningún costo por mano de obra, incluyendo aquellos solicitados para reparar fallas, reemplazamientos o cambio de cualquier parte defectuosa que se declare. Esta garantía le da derechos específicos y legales, y usted asimismo tendrá otros derechos los cuales varían de estado a estado. PROTECCIÓN REPLACEMENT PLUS El producto de ventilación Air Vent para el cual esta garantía aplica está cubierto con la protección Replacement Plus por un periodo de 5 annos (Modelo RV28) o 2 annos (Modelo RV26), a condición de que el producto haya sido instalado de acuerdo con las instrucciones escritas de instalación de Air Vent y de acuerdo con todos los estándares y códigos locales, incluyen do aquellos pertinentes al factor de riesgo de incendio en las construcciones. Bajo este aspecto de la garantia, Air Vent, sin costo alguno, remplazará cualquier pieza cubierta por la garan tia encontrada defectuosa durante el periodo marcado por la proteccion Replacement Plus (el periodo Replacement Plus inicia cuando la instalación eléctrica del ventilador sea conclui da). La responsabilidad máxima de Air Vent, bajo el periodo de Replacement Plus será igual al costo de la parte a reemplazar, incluyendo la mano de obra requerida para remover la parte defectuosa e instalar la parte de reemplazo. En circustancias en las cuales Air Vent, de acuerdo con los términos de esta garantia, haya acordado pagar el costo de la mano de obra para reempla zar una parte defectuosa, Air Vent proveerá el reembolso solamente bajo la recepción de una copia de la factura del contratista u otra evidencia escrita de la con clusión del trabajo, la cual será juzgada aceptable bajo la exclu siva discreción de Air Vent. 7.) WIRING THE THERMOSTATCONECTANDO EL TERMOSTATO Part No. 18370