Application procedures and conditions are beyond the control of the manufacturer and/or seller of FilterVent and for this reason neither manufacturer nor seller can be responsible for the failure of the product when not used according to instructions and specifications. Air VentÕs written warranty for this product shall not apply in any instance in which the product was not installed in accordance with the instructions contained herein. FilterVent ¨is a patented product of Air Vent Inc. Form 14015-8/03 © 2003 Air Vent, Inc. 3000 West Commerce, Dallas, TX 75212 309-692-6969 FAX: 1-800-635-7006 www.airvent.com DO NOT EXTEND SLOT OVER OVERHANG OF ROOF. New Construction FILTERVENT INSTALLATION INSTRUCTIONS ¨ Existing Roofs 6ý 6ý 2ý TOTAL SLOT WIDTH RIDGE SLOT END WALLSIDE WALL 1.Remove cap shingles along entire length of ridge.2.Snap chalk line along centerline of peak.3.Snap parallel lines on both sides of peak for ridge pole or truss construction. (See drawings inside.)4.Mark end of slot 6ý from inside of end wall on each end. 5. Cut through shingles to roof sheathing with utility knife.6.Strip away cut-out scrap from slot.7.Cut through roof sheathing with power saw. Set depth at sheathing thickness (approx. 3/4ý).8.Remove cut out portions of sheathing. Once slot is cut out, follow Steps 3 through 9 for New Construction. 5.Inset end plugs.6.Join FilterVent sections with connector plugs.7.Extend FilterVent past ends of slot to full length of ridge. Cut final section.8.Align joined FilterVent over slot, fasten in place.9.Place straps over joints and fasten in place. 1.Cut ridge slot for ridge pole or truss construction as shown inside.2.Shingle roof up to slot.3.Let top course of shingles lay over unslotted portion of ridge (ends) to form one thickness.4.Place FilterVent over open slot.
FILTERVENT INSTALLATION INSTRUCTIONS¨ 111/4ý long aluminum screw shank nails are supplied. For ease of installation and to prevent vent damage, #8 x 1 1/4ý long galvanized sheet metal screws may be used. 2For installation on asphalt shingles, slate, machine split shingles or other smooth surfaces, caulking is not required between the vent and roof surface. 3Before applying vent to dimensional or architectural shingles on new construction, leave felt long at ridge and fold back under vent (see drawings on other side), or caulk between low areas of shingle and flange of vent. 4When installing on flat tile, handsplit shakes, or standing seam roofs, use Tile FilterVent. Please call for assistance when using on barrel tile or high seam roofing. 5Use FilterVent products for roof slopes from 3/12 to 12/12. 6When installing these vents the slot must be cut in accordance with the illustrations shown within. 7When retrofitting, and on new installations where a ridge beam exists and the roof slope exceeds 9/12, a plumb cut must be used to keep the slot as narrow as possible. 8FilterVent works at maximum efficiency when used with an equal amount of soffit venting. This can be accomplished with Continuous Soffit Vent or 16ý x 8ý undereave louvers. 9Make all existing roof and/or gable end vents inoperable by plugging or blocking to prevent short-circuiting of the ventilation system. 10When installing straps at joints and ends, care must be taken not to distort or crush the ridge vent. 11Install connector straps at each end of the vent run. 12For best appearance, run FilterVent to ends of roof. Helpful Installation hints. Please read complete instructions before you begin!
On all installations, cut ridge slot for ridge pole or truss construction as shown below and in the architectural drawings below. Slot must not be cut within 6ý of end wall. DO NOT EXTEND SLOT OVER OVERHANG OF ROOF. FilterVenton asphalt shinges, 12/12 pitch Roof. FilterVent recommended for 3/12 to 12/12 pitch roofs.FilterVenton cedar shakes, 12/12 pitch roof. Roofing underlayment wraps around top course of shakes. Ridge Pole ConstructionAlternate 1 Ð for low pitch roofs. Typical FilterVent installations: NOTE: The illustrations at right depict the proper methods of installing ridge vents for various types of construction. FilterVent has 18 sq. in. net free vent area. It is not necessary to cut the slot extra wide. Maximum protection is attained when the vent is supported to the throat by the roof and shingles. 6ý 6ý 2ý TOTAL SLOT WIDTH RIDGE SLOT END WALL SIDE WALL New Construction FILTERVENT INSTALLATION INSTRUCTIONS ¨ Hip Roofs Cut slot 11/2ý on either side of ridge centerline and to within 6ý of end. 53/4ý 3ý TOTAL SLOT WIDTH6ý SHEATHING TRUSS OR RAFTER SHINGLES FILTERVENT 53/8ý 6 TO 1212 FILTERVENTSTARTER STRIP WOOD SHAKES SHEATHING TRUSSES 15# ROOFING FELT COURSE WITH SHAKES 7 WRAP TOP UNDER RIDGE VENT 53/8ý 11/4ý 126TO12 11/4ý SCALE: 3/16ý = 1ýSCALE: 3/16ý = 1ýSCALE: 3/16ý = 1ýSCALE: 3/16ý = 1ý FILTERVENT SHEATHING AIR SPACE RAFTERS WITH RIDGE POLE SHINGLES Ð 2 LAYERS WITH RETROFIT/REROOF 11/4ý 11/4ý 13/4ý 11/4ý 3 TO 6 13/4ý 12 3/4ý3/4ý 4ý MINIMUMSTARTER STRIP INSTRUCTIONS FOR CUTTING SLOTS
FILTERVENT INSTALLATION INSTRUCTIONS ¨ Tile FilterVenton pre-engineered standing seam metal roof. Separate adapter covers end of roof panels. Ridge Pole ConstructionAlternate 2 Ð for steep pitch roofs Tile FilterVentinstalled on either barrel roof tile or flat roof tile. Please call Air Vent for assistance when using on barrel tile or high seam roofing. Truss Construction CEMENT HERE BOTH SIDES HEX SLOTTED WASHER HEAD SCREW TILE FILTERVENTRIDGE VENT ADAPTOR (2 REQUIRED) NAILING BLOCK BETWEEN STANDING SEAMS (1ý X 3ý) STANDING SEAM ROOF ROOF SHEATH RAFTER6ý TO 12ý 53/8ý 11/2ý 11/4ý11/4ý 12ý 15# FELT ÒLÓ and ÒTÓ Shaped Roofs Cut slot and run FilterVent across long ridge. On short ridge, cut slot to within 12ý of junction point and run FilterVent from end of roof to butt against crossing FilterVent. indicates slot width indicates vent run Chimneys Cut slots to within 12ý of chimney. Run FilterVent from end of roof to butt against chimney. CONDITION WITH TRUSSES DOTTED51/4ý 1ý1ý 31/2ý2ý 12 9 FILTERVENT11/4ý WOOD SCREWS W/PLASTIC OR RUBBER WASHERS 2ý WOOD SCREWS AT EACH RAFTER/TRUSS 3/8ý X 3ý CEDAR BOARD SEALANT BEAD ROOFING/SHEATHING MINIMUM AIR SPACE 2ý RAFTERS/TRUSSES CUT OUT IN EXISTING CONSTRUCTION. OMIT IN NEW WITH 2ý RIDGE BEAMWITH TRUSSES 12ý 12ý12ý RUN FILTERVENT TO END OF RIDGE RUN FILTERVENT TO END OF RIDGE BARREL ROOF TILE 53/4ý 13/4ý 11/2ý 11/2ý 3 TO 612 3/4ý3/4ý FILTERVENTSHINGLES Ð 1 LAYER WITH NEW CONSTRUCTION, 2 LAYERS WITH RE-ROOF SHEATHING AIR SPACE TRUSSES SEALANT ROOF TILE 53/8ý 11/2ý 11/2ý11/2ý 3/4ý3/4ý FLAT ROOF TILE TILE NAILER AIR SPACE RAFTER RIDGE POLESHEATHING TRUSS NAILER 126 TO 12 TILE FILTERVENTÐ3-PIECE FLANGE COVERS END OF TILE HEX SLOTTED WASHER HEAD SCREW