    							- INSTRUCTIONS -
    Form C Relay for 12-18V DC Intercom Systems with Door Release
    WIRING DIAGRAMS:
    Page 1
    INSTALLATION:
    1. Install in a suitable location, either near the power source for the door release mechanism, or behind the intercom.
    2. Secure wire connections with proper termination, such as wire nuts or crimp connectors.
    3. Trim the wires to the desired length. 
    4. Cut the unused contact wire so the bare strands are not exposed.
    RY-18L COLOR CODE:
    Input of Relay:
    Red:L/RED, Postive trigger
    Gray:(-) NEGATIVE
    Output of Relay:
    Brown:COMMON
    Orange: N.O. Contact
    Yellow:N.C. Contact
    (See contact rating specs on 
    back page) The RY-18L Door Release Relay Module is an interface between the door strike contacts on the Aiphone unit and the 
    actual release mechanism. The contact ratings on Aiphone units vary, and are all Normally Open. If your strike or 
    maglock is a higher voltage or draws more current than specified for the unit, the RY-18L is required. It provides either a 
    Normally Open contact for an electric strike, or a Normally Closed contact for a magnetic lock. The contact rating 
    supports a majority of door release hardware available on the market. This relay is recommended with all JF, JK, and JO  
    systems when using the single door release feature, and for the LEM-1DL or LEF systems when connecting a maglock.
    MAGNETIC LOCK WIRING METHOD:
    (Normally Closed contact)
    Lock Power: Power source for Magnetic Lock
    When using 12-18V DC power, use the RY-18L.
    When using 24V DC power, use the RY-24L.
    LE-Series Sub
    1
    E
    +
    -
    EL
    EL
    LEM-1DL
    ~
    ~
    PT-1210N
    1
    E
    -
    Leave jumper 
    between E and -
    attached
    RedGry
    Brn
    Org
    YelCOM
    N/C
    Use Brown & Yellow wires 
    when connecting to Maglock.
    LOCK 
    POWER
    RY-18L
    Magnetic Lock
    RED:   L/RED
    BLK:   (-) Neg.
    BRN:   Common
    ORG:  N.O.
    YEL:   N.C.
    +
    -
    30405     0114
    1
    E
    +
    -
    L
    K11
    E
    -
    LEF-5 LE-Series Sub
    +
    -
    PS-1225UL
    Red
    Gry
    Brn
    Org
    Yel
    RY-18L
    LOCK 
    POWER
    +
    -
    Magnetic Lock
    COM
    N/C 
    						
    							NOTE:
    Release contacts on the JF-2MED are from 
    4-pin connector included with unit. 
    Connect Red & Brown wires as shown. 
    Orange & Yellow wires are not used.
    Release contacts on the JK-1MD/MED and 
    JO-1MD/FD are L/L terminals.
    Aiphone Communication Systems
    1700 130th Ave. N.E.
    Bellevue, WA  98005
    (425) 455-0510
    FAX (425) 455-0071
    Toll Free Technical Support:
    1-800-692-0200
    E-mail [email protected]
    RY-18L Instr.
    0114JD
    SPECIFICATIONS:
    Power Source: Supplied by master station
    Mounting: No mounting required
    Terminations: Color-coded prewired pigtails
    Relay Input: 12-18V DC, Red, Gray wires, 22AWG
    Relay Output:  Brown, Red, Orange wires, 18AWG
    N/O Output rating: 5A at 30V DC
    10A at 125V AC
    3A at 250V AC
    N/C Ouptut rating:  3A at 30V DC or 125V AC
    Wiring: 2 conductors from monitors door release contacts to RY-18L. 
    2 conductors from RY-18L to strike, with power for strike wired in series.
    Dimensions (HxWxD):  1-3/4  x  7/8 x  7/16, with wires extending approx. 7-1/2
    WIRING DIAGRAMS:
    A1
    A2
    B1
    B2
    S
    S
    DC 18V
    +
    -
    RELEASE
    (L)BRN
    (L)RED
    JK-1MD/MED
    JF-2MED
    JO-1MD/FD
    Door
    A1
    A2
    PS-1820UL
    +
    -
    .
    RedGry
    Brn
    Org
    Yel
    COM
    N/O
    N/C
    Use Normally Open 
    contact for electric strike
    ELECTRIC STRIKE 
    WIRING METHOD: JF/JK/JO OPEN VOICE COLOR VIDEO SYSTEM:
    PS-1820UL
    +
    -
    .
    RedGry
    Brn
    Org
    Yel
    COM
    N/O
    N/C
    Use Normally Closed 
    contact for magnetic lock
    MAGNETIC LOCK 
    WIRING METHOD:
    A1
    A2
    B1
    B2
    S
    S
    DC 18V
    +
    -
    RELEASE
    (L)BRN
    (L)RED Add 
    jumper 
    wire from 
    BRN to +
    Add 
    jumper 
    wire from 
    BRN to +
    NOTE:
    Only wiring pertaining to connection of door 
    release relay is shown here. 
    For complete system information, please 
    consult the main system installation manual. 
    +  -
    LOCK 
    POWER
    +  -
    LOCK 
    POWER
    JK-1MD/MED
    JF-2MED
    JO-1MD/FD 
    						
    All Aiphone manuals Comments (0)

    Related Manuals for Aiphone RY18L Instructions User Manual