Home > Aiphone > Telephone > Aiphone NH50AC Instructions User Manual

Aiphone NH50AC Instructions User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Aiphone NH50AC Instructions User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 161 Aiphone manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Brn
    Red
    Gray
    Brn
    Red
    Gray
    -INSTRUCTIONS -
    WIRING DIAGRAM:
    All Call Adaptor for NHX System
    1 NH-50AC for All Call up to 49 Stations, 2 NH-50AC for up to 79 Stations
    NHX-80X
    11
    12
    ~
    21
    22
    ~
    31
    32
    ~
    41
    42
    ~
    51
    52
    53
    54
    55
    56
    NOTES:
    1. The application requires one of the station buttons to be 
    used for All Call.  
    Therefore, the standard system can have up to 49 stations, 
    and the expanded system can have up to 79 stations.
    2. Only wiring concerning the NH-50AC is shown here.  For 
    complete installation and wiring information, please see the 
    NHX Installation instructions. PS-1225UL
    +
    -
    Trunkage Line 
    Connection 
    Terminals
    Some applications for Nurse Call systems require All Call. By including this adaptor, a station button on the master 
    can be used to call all of the patient stations simultaneously. An additional wire is required to each patient station.   
    NOTE: An NHX system installed with an NH-50AC included does not carry the UL 1069 listing. 
    NHX
    Nurse Call System
    11   1B
    12    1R
    BL
    21 2B
    22 2R
    BL
    31 3B
    32 3R
    BL
    41 4B
    42 4R
    BL
    51
    52
    5B
    A1 5R
    A2 BL
    P3
    P4
    D5
    D6
    X1
    +
    -
    AUX
    NH-50AC
    Brn
    Red
    Blk
    Trunk #1 
    Patient Stns*
    Brn
    Red
    Blk
    Trunk #2 Patient 
    Stns*
    Trunk #5 
    Patient Stns*
    Connections to 2nd NH-50AC:
    X1: Control wire
    A1: Audio
    A2: Audio
    12V+: Power 
    12V-: GroundBrn
    Red
    Gray
    Brn
    Red
    Gray
    * Patient Stations for All Call:
    Model NH-1SA/AC or NH-2SA/AC. 
    Additional BLACK wire coming from back of 
    unit connects to Gray wire of trunkage cable, 
    and to BL terminal of NH-50AC.
    IMPORTANT:
    Connection from CCU trunk line terminals determines which 
    column the All Call button will be on. (e.g. This example 
    shows trunk line 5, so All Call button will be on column 5  of 
    master station. Dip switch settings on the NH-50AC will 
    designate the All Call button position (1~10).
    Pg. 1
    Org
    Yel
    Grn
    Blu
    Brn
    Red
    Blk
    Trunk #3 Patient 
    Stns*
    Trunk #4 Patient 
    Stns*
    Brn
    Red
    Gray
    Brn
    Red
    Blk
    Brn
    Red
    Blk
    Org
    Yel
    Grn
    Blu
    Jumper to 
    Negative of 
    one PS-2420UL
    0708
    To AUX input of 2
    ndNH-50AC
    To 2ndNH-50AC
    (For 50-79 station system)
    } 
    						
    							NH-50AC Front
    CONTROLS AND SETTINGS:
    DIP SWITCH SETTINGS:
    1-2-4-8 Switches: (labelled 1, 2, 3, 4 on actual switch)
    1. Set dip switches to the numerical value of the station button 
    you are designating as the ALL CALL button.  (Recommended to use 10)
    2. Station numbers are 1-10 vertically on the master station.  
    If the All Call button is the TOP button on a column, set dip switch 1 to ON.   
    If the All Call button is the BOTTOM button, set switches 2 & 8 to ON.
    TRUNK VOL.:
    These switches adjust the output volume level of the All Call to each group of stations (trunk lines).
    Adjust the switch to LOW, MID, or HI for the desired volume.
    ALL CALL VOL.:
    This controls the overall output volume of the All Call.  Adjust to the desired level.
    VOL.ALL CALL
    VOLUME
    WIRING:
    1.  Follow the wiring diagram on page 1 of these instructions.
    2.  Connection from NHX-80X to A1, A2, P3, P4, D5, D6 terminals of the NH-50AC correspond to 
    which trunk line the All Call button is on. If the All Call button is on column 5 of the master,
    connect as shown on the diagram. If the All Call button is on any other column on the master,
    connect A1~D6 from appropriate corresponding trunk line terminals of NHX-80X.
    3.  The P3, P4, D5, D6 terminals act as a junction point for the common wires of the trunk line
    that the All Call adaptor is on. The NH-50AC has to be wired directly from the NHX-80X, then
    the patient station trunk wires go out from there.
    4.  Wiring from the NH-50AC to patient stations require an extra wire. Use the GRAY wire from
    the Aiphone #862208 trunk cable to connect the BLACK wire of the patient stations to the BL
    terminal of the NH-50AC. (Two BL terminals are paralleled internally, so either of them can be
    used.)
    5.  The X1 terminal is only used in systems beyond 49 stations when a second NH-50AC is 
    required.  The AUX input is only used on the second All Call adaptor.  Wire the A1, A2 
    terminals of the first adaptor to the AUX input of the second.
    OPERATION:
    1.  Press button on the master station that has been designated as the ALL CALL button.
    2.  Pick up handset and make announcement, or press and hold TALK button while speaking.
    3.  Hang up handset, or press OFF button when ALL CALL announcement is completed. 
    SPECIFICATIONS:
    Power Source: 12V DC.  Use PS-1225UL, one per system (powers one or two NH-50AC)
    Communication: Handset or push-to-talk.  All Call is transmit only.
    Wiring: 16 conductors from NHX-80X to NH-50AC
    1 pair from trunkage line plus one additional wire output to patient stations
    5 conductors from first to second NH-50AC
    Aiphone Communication Systems
    1700 130th Ave. N.E.
    Bellevue, WA  98005
    (425) 455-0510
    FAX: (425) 455-0071Toll Free Technical Support:
    1-800-692-0200
    E-mail [email protected]
    NH-50AC Instr
    0708JDJS
    ON
    OFF1  2  4  8
    1  2  3  4
    Back
    ALL CALL
    TRUNK 
    VOLUME
    1  2  3  4  5 HI
    MID
    LOW 
    						
    All Aiphone manuals Comments (0)

    Related Manuals for Aiphone NH50AC Instructions User Manual