Home > Aiphone > Telephone > Aiphone NENVPC Instructions User Manual

Aiphone NENVPC Instructions User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Aiphone NENVPC Instructions User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 161 Aiphone manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							+
    -
    - INSTRUCTIONS -
    The NE-NVP/C is a vandal proof and weather resistant sub station designed for use with the NEM system.  
    It is constructed of 12 gauge carbon steel with a white powder-coated finish.  The NE-NVP/C will flush 
    mount into a 3-gang masonry type box (Raco model 692 or equivalent) or surface mount using the 
    SBX-NVP.  Tamper proof screws and a tool for installation are included.
    WIRING DIAGRAM:
    Vandal Proof  and Weather Resistant Sub Station for NEM
    SBX-NVP 
    Surface Mount Box for NE-NVP/C
    Pg. 1
    1
    2
    3
    ~
    20
    E
    +
    -
    HRed
    Blk
    Blu
    Red
    Blk
    Blu
    Wht
    NEM, NDRNE-NVP/C
    NE-NVP/C
    PS-2420UL
    Red
    Blk
    Blu
    NE-NVP/C
    Blu
    Blu
    NBY-4ARY-PA
    BlkBlk
    Yellow
    Front View Back View
    5-½”
    7-½” 
    						
    							SPECIFICATIONS:
    Power Source: Supplied by master station.
    Speaker: 20 ohms, 2.5 diameter, water proof and puncture resistant, 2.4 oz. ceramic magnet.
    Call Button: SPST call button, momentary activation.
    Call Annunciation: Pressing the call button at sub activates and latches call at NEM master. The master
    stations LED will be lit and a ringing tone will be heard until the call is answered.
    Communication: Hands free at sub.  Master is push-to-talk or VOX handset.
    Faceplate: 12 gauge carbon steel with powder-coated white baked epoxy finish.
    Mounting Hardware: T10 Torx tamper proof screws and tool included (6x32 for use with flush gang box)
    Terminations: Color-coded prewired pigtails
    Wiring: 2 conductors homerun; or 1 common plus 1 individual per sub, looped through each sub.   
    Shielded cable is recommended.  
    Use Aiphone #822202 or #821802 for homerun wiring, #822206 for up to 5 stations  
    on each run, or #822210 for up to 9 stations on each run.
    Wiring Distance: 420 with 22AWG; 1,000 with 18AWG. 
    Dimensions (HxWxD):  NE-NVP/C alone:  7-1/2 x 5-1/2 x 2.  With SBX-NVP:  8-5/8 x 6-5/8 x 2-1/4
    Mounting Depth:  Provide mounting box with a minimum depth of 2-1/2 to allow space for internal components.
    Aiphone Communication Systems
    1700 130th Ave. N.E.
    Bellevue, WA  98005
    (425) 455-0510
    FAX (425) 455-0071
    Toll Free Technical Support:
    1-800-692-0200
    E-mail [email protected]. 2
    NE-NVP/C Instr.
    0512JD
    +
    - WIRING DIAGRAM:
    1
    E
    H
    2
    E
    H
    3
    E
    HRed
    Blk
    Wht
    Blu
    NDRM Master
    CP-544A board
    NE-NVP/CNE-NVP/C
    (w/dry closure output)
    PS-2420UL
    RY-PA BlkBlk
    Yel Dry closure 
    output for 
    duration of 
    call-in
    A+
    A-
    B+
    B-
    H
    Q
    E
    S
    B
    Y
    A1
    V1
    A2
    V2
    CP-544A board
    Red
    Blk
    Wht
    Blu
    OPERATION:
    1. To place a call from the remote station: Press the call 
    button once, then release and wait for a response 
    from the master station.  The call tone and LED 
    indicator at the master will remain activated until the 
    call is answered.  The call indicator LED on the door 
    station will be lit to indicate that a call has been 
    placed.
    2. To answer the call at the master station: Press the 
    channel selector button with the lit LED, which              
    indicates which remote has called in. Press TALK 
    button to talk, release to listen.
    3. Speak hands free at the remote station.
    4. To conclude the call, press the OFF button.
    5. To initiate a call from the master station to the remote, 
    simply press the channel selector button, then                     
    TALK to speak to the person at the remote. 
    6. Press OFF to conclude the call.  
    						