    LEM-1DL Supplement
    Pg. 1
    The LEM-1DL master station provides communication to and from a door station, and h\
    as a separate button 
    for door release. This supplemental instruction manual addresses many of the additional fu\
    nctions and 
    modifications for the LEM-1DL system, including installation and troubleshooting information.
    REFER TO INSTALLATION MANUAL INSIDE LEM-1DL BOX FOR STANDARD INSTALLATION INFORMATION
    MASTER STATION:
    LEM-1DL: 1-call master station with “Normally Open” door 
    release button
    DOOR STATIONS: 
    (Note: Door stations are weather resistant, made for outdoor use)
    LE-D:  Surface mount, plastic door station
    (included with LEM-1DLS Set)
    LE-DA:  Flush mount in 2-gang box, stainless steel cover
    LS-NVP/C:  Vandal resistant flush mount in 3-gang box, white 
    powder-coat finish
    LE-SS/A:  Vandal resistant flush mount sub in 2-gang box, 
    stainless steel
    LE-SSR:    Vandal resistant, red mushroom button, flush mount 
    in 2-gang box, stainless steel
    LE-SS-1G:  Vandal resistant flush mount sub in 1-gang box, 
    stainless steel
    Watch our how-to wiring video online.
    LEM-1DLS Set contains:
    1 LEM-1DL, 1 LE-D, 1 PT-1210N. Door strike not included.
    2 cond. shielded for intercom
    LEM-1DLLE-DLE-DALS-NVP/CLE-SS/A
    DAK-2S(2 component modules per kit)
    Separate 2 conductor for door release If using a non-Aiphone door strike, use separate power 
    source for door release mechanism.
    LE-D LEM-1DL
    PT-1210N
    Power 
    Source 
    for Strike
    !
    How-To
    Video Link
    OPTIONAL COMPONENTS & ACCESSORIES:
    RY-AC/A:  External signaling relay (Requires 12VDC power 
    supply)
    DAK-2S:  Dual master adaptor kit (1 per 2 master stations. Use 
    2 DAK-2S for up to 4 total master stations)
    SBX-NVP:  Surface mount box for LS-NVP/C
    SBX-2G:    Surface mount box for LE-SS/A, LE-SSR, LE-DA
    SBX-1G:    Surface mount box for LE-SS-1G
    EL-12S:  Door strike (for interior wood frame doors only)
    PT-1210N:  AC 12V Transformer (used for door strike and for 
    each master station)
    PS-1225UL:  12V DC Power Supply, 2.5A, UL Listed
    822202:  2 conductor, 22AWG, Shielded wire
    (Available in 500’ and 1000’ boxes) Install two separate runs of 
    this cable, one for the intercom and one for the door release.
    LEM-1DL Supplemental Instructions
    Single Master Station with Door Release         
    						
    							Please read and understand all 
    instructions before installation.
    LEM-1DL Supplement
    Pg. 2 WIRING DIAGRAM: Dual Master LEM-1DL System with DAK-2S Dual Master Adaptor
    OPERATION NOTES:
    1.  Only one master can be used at a time.
    2.  If both masters are activated, a feedback (squeal) will be heard t\
    hrough the system when either TALK button is pressed.
    3.  If feedback occurs, press the OFF button on one of the LEM-1DL masters.
    INSTALLATION GUIDELINES:
    1.  Use 2 conductor shielded wire from the door station to the first master, then to the second master.
    2.  Install the units at the desired locations.
    3.  Separate PT-1210N power supplies are required for each master station. NOTE: Connect power leads to master BEFORE plugging  in power supply.
    4.  Install the bare wire leg of the component module directly onto the \
    “1” terminal of the LEM-1DL’s. 
    5.  Attach the wire coming form the “1” terminal of the LE-D to the co\
    lored wire end of the component modules at both masters. (The component          
         modules will easily fit within the space available.)
    6.  Connect the “E” terminal between the door station and master s\
    tations.
    7.  If door release is included, use a separate 2-conductor wire from th\
    e “EL” terminals of the masters through an AC transformer and to the door strike.
    8.  The EL-12S is designed for a standard wood framed door and for light to \
    medium usage. If a different type of door is used, install a strike              
         appropriate for the door.
    9.  The door release button on the master station is a “Normally Open” contact closure.  Contact rating is 30V AC/DC @ 1 Amp.
    IMPORTANT!!!
    Each master  REQUIRES an individual power supply.
    1
    E E
    - 1
    EL
    EL +
    E
    - 1
    EL
    EL
    +
    -
    4 LEM-1DL Master Stations with 1 Door
    Note: In a multi-master system, all masters only talk to the 
    door station, and only one master can be on at a time
    LE-D LEM-1DLLEM-1DLLEM-1DL
    LEM-1DL
    Component 
    Module Component 
    Module Component 
    Module Component 
    Module
    PT-1210N PT-1210N
    PT-1210N PT-1210N
    LE-D
    LEM-1DL
    PT-1210N LEM-1DL
    PT-1210N
    Component  Module Component 
    Module
    Leave 
    E/- jumper 
    attached
    If using a non-Aiphone door strike, 
    use a separate power source for the 
    door release mechanism.
    !
    Aiphone EL-12S
    1
    E
    - E
    - 1
    EL
    EL +
    E
    - 1
    EL
    EL + 1
    E
    - 1
    EL
    EL +
    E
    -
    EL
    EL +
    Door Strike
    Power Source 
    for door strike                  
    						
    							1
    E
    -
    E
    - 1
    EL
    EL
    + -RY-AC/A
    BELL
    LE Series Sub LEM-1DL
    +
    -
    LOCK
    POWER
    RY-18L / RY-24L
    Magnetic Lock
    COMN/CBrn
    Org
    Ye l
    Blk
    Red
    Use Brown & Yellow wires 
    when connecting to a Maglock.
    LEM-1DL Supplement Pg. 3
    WIRING DIAGRAM: LEM-1DL System with External Signaling using RY-AC/A Relay
    MAGNETIC LOCK WIRING METHOD:
    (Normally Closed Contact)
    Lock Power: Power source for Magnetic Lock
    When using 12-18V DC, use the RY-18L
    When using 24-36V DC, use the RY-24L
    Leave 
    E/- jumper 
    attachedLeave 
    E/- jumper 
    attached
    +
    1
    E
    - E
    - 1
    EL
    EL +
    SYSTEM CONFIGURATION: 
    LEM-1DL with Door Release contact activating a Normally Closed relay for a Mage\
    ntic Lock
    Note:  For applications requiring a Normally Closed (N/C) contact (Ma\
    gnetic locks, etc.), an external
    relay should be chosen based on the lock’s power source.
     
    - When using a 12-18V DC magnetic lock, Aiphone’s RY-18L relay may be used.
      - For 24V DC magnetic locks, Aiphone’s RY-24L relay may be used.
      - A 3rd party relay of similar specifications may also be used.  Refer to manufacturer’s      
        documentation for connection details.
    Normally Open Dry 
    Contact to door 
    strike and powerComponent Module
    If a DAK-2S is not available, install components as shown below.
    Capacitor: 25V, 15-33ufd Non-polarized
    Diode: 1N4148 Output of RY-AC/A (Yellow 
    wires) provide a momentary 
    dry contact closure while 
    the call button on the door 
    station is being pressed.
    PS-1225UL
    NOTE: Intercom must be 
    powered with a 12VDC 
    power suplly when 
    RY-AC/A is connected.
    LEM-1DLComponent  ModuleLE-D
    White
    Red
    Black
    Power source for bell
    To 1 of LE-D and 
    WHITE wire of RY-AC/A To 1 of LEM-1DL       
    						
    							INSTALLATION TIPS:
    1.  Use shielded wire for the communication path, and ground one end of \
    the shield to an earth ground.
    2.  Run intercom wire at least 20” away from AC wiring, fluorescent lights or dimmer switches. 
    3.  Keep intercom cable away from alarm, data, phone, and video cables. 
    4.  Door release wires must be in a separately jacketed cable from the i\
    ntercom wires. Use two separate                
         cables; one for audio and one for door release.  
    5.  When installing a second master station, wire must be run from the first master station, not from the          
         door station. See diagram on page 2. 
    6.  Do not install master station near light switches, dimmer switches, \
    or other devices that may cause           
         interference with the intercom system. 
    7.  Do not install the master station on the opposite wall from the door\
     station. If the units are too close,          
         acoustical feedback may result.
    TROUBLESHOOTING GUIDE:
    Aiphone Corporation
    www.aiphone.com
    [email protected]
    (800) 692-0200LEM-1DL Supplement Pg. 4
    #90111
    0214JD
    PROBLEM POSSIBLE CAUSESOLUTION
    No call tone from door to master station. (A) OFF button on master not pressed.
    (B) E/- jumper not attached.(A) Press OFF button on master.  If call tone still doesn’t come 
    through, read solution (B).
    (B) Make sure jumper is attached to E/- terminals on door 
    station (or proper wires jumpered on LS-NVP/C, LE-SS/A 
    subs).  Wire from E/- should be connected to E of master.
    No communication from door station. E/- jumper not attachedEnsure that the jumper at the door station is attached between 
    E and - terminals
    No call tone, no communication.  Chirping 
    sound when volume control is turned all the 
    way up. Wrong voltage on LEM-1DLCheck power supply.  If it’s a model SKK-620B, remove and 
    replace with model PT-1210N.  Verify that voltage on +/- 
    terminals is between 12-16V AC or 12-24V DC.
    In system with RY-AC/A and external signaling 
    device connected, the external device is 
    activated every time TALK button is pressed. DAK-2S component module missing or 
    installed incorrectly.Make sure the component module is installed with the bare 
    wire under the 1 terminal and the white wire of the RY-AC/A 
    spliced to the colored wire.
    In a dual master system, call tone is heard 
    at the second master when pushing the talk 
    button on one master. Missing DAK-2S dual master adaptor 
    kit.Install 1 component module from the DAK-2S at each master.  
    See Pg. 2. If DAK-2S is not available, connect specified diode 
    and capacitor in parallel and install as shown on PG. 3.
    In a dual master system, feedback occurs 
    when pressing the talk button. One power supply is used for both 
    masters.Ensure that each master has its own power supply.  Use any 
    power supply with output between 12-16V AC or 12-24V DC.  
    Aiphone recommends the PT-1210N.
    AC noise when listening to the door station Intercom wiring run close to AC wiring.Ensure that the intercom wire is run at least 20” from any AC 
    electircal wire, or crossed at 90 degrees.  Intercom wire should 
    be shielded, with the drain wire connected to an earth ground 
    at the master end.
    AC noise when talking to the door station Power wires run with communication 
    wires.Ensure that power wires coming from the PT-1210N are not 
    run in the same jacket cable with the communication wires run 
    to the door. 
    						