Home > Aiphone > Telephone > Aiphone LEF5NE LEW5NE Instructions User Manual

Aiphone LEF5NE LEW5NE Instructions User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Aiphone LEF5NE LEW5NE Instructions User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 161 Aiphone manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							- INSTRUCTIONS -
    LEF-5-NE/LEW-5-NE
    5-call Master Station
    Master Station for use with the NEM and NDR Systems
    Aiphone Communication Systems 1700 130th Ave. N.E. 
    Bellevue, WA  98005
    (425) 455-0510
    FAX (425) 455-0071
    LEF-5-NE Instr. Page 1
    Toll Free Technical Support:
    1-800-692-0200
    E-mail [email protected]
    N1 D1 
    N2 D2
    N3 D3
    N4 D4
    N5 D5 
    NE HQ 
    L1 
    K1
    L2
    K2
    L3
    K3
    L4
    K4
    L5
    K5
    LE
    RF1 2
    Blk
    + -
    1 2345
    ~
    40 E
    H
    Q
    + -
    PS-2420UL
    NDR-40 LEW-5-NE/B
    AdaptorNE-DA
    +-PS-1225UL
    The LEF-5-NE is a 5-station master, equipped with a  door release button, and able to integrate into a larger 
    NEM or NDR system. In applications where up to 5 do or stations needs to be answered from the main NEM/
    NDR master as well as additional small master stati ons, the LEF-5-NE can be used. The LEW-5-NE  adaptor 
    is required .  This system can be used with the following subs:   NE-DA, NE-JA, NE-SS/SSR, NE-NVP/C,   
    NE-NVP-2DC-LE, NE-NVP-RA.
    NOTE: Standard LE-series sub stations cannot  be us ed 
    in a system with the LEF-5-NE master stations. The  LED 
    timing circuit in the LEF is modified. 
    The NA-A and NA-AN also cannot be used to call the 
    LEF-5-NE, but can be connected directly to the NDR/
    NDRM master station.  
    NE-JA
    Wire each door  
    station to a 
    designated 
    number station 
    as shown here.
    To Door 
    Strike for  Door #4
    To Door 
    Strike for  Door #1
    1 234
    Blk
    Grn
    RY-PA BlkYel
    RY-PABlk
    Yel
    Diode value:
    1N4001 ~ 4007
    1
    K1 2
    K2 3
    K3 4
    K4 5
    C E
    R L
    + -
    LEF-5-NE
    1
    K1 2
    K2 3
    K3 4
    K4 C5
    E
    R L
    + -
    LEF-5-NE
    K Terminal connections  
    are required in this 
    application, with or without 
    door release being included. 
    Leave jumper  intact
    WIRING DIAGRAM:  using NE-DA and NE-JA subs
    0113          
    						
    							RY-PABlkYel
    Aiphone Communication Systems
    1700 130th Ave. N.E. 
    Bellevue, WA  98005
    (425) 455-0510
    FAX (425) 455-0071
    Page 2
    Toll Free Technical Support:
    1-800-692-0200
    E-mail [email protected]
    N1 D1 
    N2 D2
    N3 D3
    N4 D4
    N5 D5 
    NE HQ 
    L1 
    K1
    L2
    K2
    L3
    K3
    L4
    K4
    L5
    K5
    LE
    RFRed
    Blk
    Wht
    + -
    1 2345
    ~
    40 E
    H
    Q
    + -
    PS-2420UL
    NDR-40 LEW-5-NE/B
    AdaptorNE-SS/SSR
    +-
    PS-1225UL
    1
    K1 2
    K2 3
    K3 4
    K4 5
    K5 E
    R L
    + -
    LEF-5-NE
    Wire each door  
    station to a 
    designated 
    number station 
    as shown here.
    To Door 
    Strike for  Door #5
    RY-PA Blk
    Yel
    To Door 
    Strike for  Door #1
    Diode value:
    1N4001 ~ 4007
    Red
    Blk
    Wht PurBlu
    Org 
    Org Yel
    Yel
    NE-NVP-2DC-LE
    Grn 
    wire
    Grn 
    wire
    NOTE: K  
    Terminal 
    connections are 
    required in this 
    application, with 
    or without door 
    release being 
    included. 
    WIRING DIAGRAM:  using NE-SS/SSR and NE-NVP-2DC-LE  subs 
    						
    							RY-PABlkYelTo Door 
    Strike for  Door #5
    N1 D1 
    N2 D2
    N3 D3
    N4 D4
    N5 D5 
    NE HQ 
    L1 
    K1
    L2
    K2
    L3
    K3
    L4
    K4
    L5
    K5
    LE
    RF
    +
    -
    PS-2420UL
    NDR-20A-RS LEW-5-NE/B
    AdaptorNE-NVP-RA
    +-
    PS-1225UL
    1
    K1 2
    K2 3
    K3 4
    K4 5
    K5 E
    R L
    + -
    LEF-5-NE
    Wire each  
    station to a 
    designated 
    number station 
    as shown here.
    RY-PA Blk
    Yel
    To Door 
    Strike for  Door #1
    Diode value:
    1N4001 ~ 4007
    NOTE: K  
    Terminal 
    connections are 
    required in this 
    application, with 
    or without door 
    release being 
    included. 
    Blue 
    Blue
    NAR-2A*
    * Reset Button: 
    (Any normally closed 
    button or keyswitch. 
    Not required when 
    using the NEM-RS 
    master.)
    1 2345
    ~
    20 E
    H
    Q S+ -Red Blk
    Gray
    Blue Pur
    Org Yel
    Grn 
    wire
    Red
    Blk
    Wht
    NE-NVP/C
    WIRING DIAGRAM:  using NE-NVP-RA and NE-NVP/C subs
    Aiphone Communication Systems 1700 130th Ave. N.E. 
    Bellevue, WA  98005
    (425) 455-0510
    FAX (425) 455-0071
    Page 3
    Toll Free Technical Support:
    1-800-692-0200
    E-mail [email protected] 
    						
    							Aiphone Communication Systems1700 130th Ave. N.E. 
    Bellevue, WA  98005
    (425) 455-0510
    FAX (425) 455-0071
    Page 4
    Toll Free Technical Support:
    1-800-692-0200
    E-mail [email protected]
    N1 D1 
    N2 D2
    N3 D3
    N4 D4
    N5 D5 
    NE HQ 
    L1 
    K1
    L2
    K2
    L3
    K3
    L4
    K4
    L5
    K5
    LE
    RF
    -
    +
    PS-1225UL
    LEW-5-NE/B Adaptor
    +-
    PS-1225UL
    1
    K1 2 34
    C 5
    E
    R L
    + -
    LEF-5-NE
    Red Blk
    Wht PurBlu
    Org 
    Org Yel
    Yel
    NE-NVP-2DC-LE
    Grn 
    wire
    1
    K1 2 345
    C E
    R L
    + -
    LEF-5-NEConnect with wires
    of the standard call button to activate a call when the  RED button is pressed.
    WIRING DIAGRAM:  with no NEM or NDR master being us ed 
    						
    							OPERATION: 
    1.  Pressing the call button at the door/sub station will activate the call tone, plus light the 
    appropriate station LED at the NEM/NDR master.  The  call tone will be heard at the LEF-5-NE  
    master(s) continually until the call is answered fr om any master in the system.   
    2.  To answer the call on the LEF or NEM/NDR master , press the station button corresponding to 
    the lit LED, then press TALK to speak to the visito r. When the first master answers the call, 
    the Occupied lamp will be lit on all other masters.  DO NOT answer the call if the Occupied 
    lamp is lit.
    3.  Communication at the master station is press-t o-talk, release-to-listen.  Communication at 
    the door station is hands free.
    4.  With communication established to the door stat ion, pressing the door release button will 
    activate the door release mechanism at the correspo nding door.
    5.  When the call is completed, press OFF on the LE F master, or the associated black OFF 
    button on the NEM/NDR master. The Occupied lamp wil l go out on all masters when the call  
    is cancelled. 
    SPECIFICATIONS:
    Power Source: 12V DC at master.  Use PS-1225UL. 
    Communication Output: 800mW @ 20 ohms (receive); 500m W @ 20 ohms (transmit)
    Communication: Push-to-talk, release-to-listen at ma ster station.
    Hands free at sub station.
    Calling: Master to sub:  By voice  Sub to master:  Mono-electronic call tone
    Compatible Remotes: NE-DA, NE-JA, NE-SS/SSR, NE-NVP/ C, NE-NVP-2DC-LE,
    NE-NVP-RA
    Wiring: 3 conductors from door/sub to LEW-5/NE Adapt or (Aiphone #822203)   
    2 common plus 2 individual conductors per door from  
    LEW-5-NE to LEF-5-NE (Max. 12 conductors with 5 doo r stns)
    (Aiphone #822212)
    7 conductors from LEW-NE to NEM/NDR master (Aiphone  #822212)
    2 conductors from master to their respective power  supply.
    Shielded cable is recommended.
    Wiring Distance: 420 with 22AWG; 1,000 with 18AWG.  
    Dimensions (H x W x D): 7 x 5-1/2 x 2-1/4  (dimen sions are for the LEW-5-NE)
    Aiphone Communication Systems
    1700 130th Ave. N.E. 
    Bellevue, WA  98005
    (425) 455-0510
    FAX (425) 455-0071
    Page 5
    LEF-5-NE  Instr. 0113PHToll Free Technical Support:
    1-800-692-0200
    E-mail [email protected] 
    						
    All Aiphone manuals Comments (0)