Aiphone IPW1A Instructions User Manual
Have a look at the manual Aiphone IPW1A Instructions User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 161 Aiphone manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
- INSTRUCTIONS - The IPW-1A offers voice-quality Intercom function over standard IP based networks. Designed specifically to integrate seamlessly into a new or existing LAN / WAN infrastructure, the IPW-1A system is capable of supporting hundreds of stations. Providing intercom/paging solutions to a large variety of applications including commercial, industrial, residential, general security, office, and institutional. IPW-1A Intercom-Over-IP Adaptor Pg. 1 1 NAMES & FEATURES FEATURES: · Cost-effective multi-master (PC-based) based design · Compatible with IE Series sub stations and AX-DM · Scalable to hundreds of stations / locations · Works with standard wired and wireless network infrastructure. (LAN/WAN) · Digital audio recording and playback capability via included software. · Relay output for remote release (N/O or N/C) IPW-1A 0211 Package Contents: (1) IPW-1A (1) PT-1211C (1) Mounting hardware (1) Software CD (1) Install manual Rear plate IN0 IN1 NC C NOPWR Front plate NAMES & FUNCTIONS: 1.Reset switch (reset unit) 2.RS-232 Serial Port (for firmware recovery) 3.Green and Red Status Lights 4.Sub station connector 5.Door release relay output & external input. Door release:NC = Normally closed contactNO = Normally open contact C = Common External input:IN0 = call button input (simulates door call in)IN1 = sensor input (changes icon in CommuniCenter adaptor list)Gnd = ground 6.RJ-45 10/100 ethernet jack & connection indicator LED’s (network connection) 7.Power input connector 1234 567 IN0 IN1 NO C NC
2 INSTALLATION & MOUNTING Installation Instructions: 1.If the IPW-1A adaptor is not on the same LAN or network segment as the PC master station, ensure that the IPW-1A has been pre-programmed with the proper connection settings prior to physical adaptor installation. See the CommuniCenter Operations manual (included on CD with IPW-1A). 2.Wire the sub station to the proper connector on the IPW-1A, and connect to the network using the standard RJ-45 jack. Wiring from the sub station to the IPW-1A should be a 2-conductor, shielded cable. Connect the PT-1211C power supply included to the power input connector. Mounting Instructions: 1.Mount the IPW-1A adaptor in a controlled area or in an enclosure suitable to the installation environment. The IPW-1A chassis is neither vandal resistant nor weather resistant. Secure the provided mounting bracket and then slide the IPW-1A onto the bracket as shown. If mounting the unit on a shelf, attach the 4 rubber feet that are included. Pg. 2 Wiring to sub station should be 2-conductor shielded cable.Wire distance from IPW-1A to IE series sub station: 22AWG = 387 feet, 18AWG = 980 feet RESETRS-232STATUSSUB PT-1211C SUB 1 2Audio Only DoorIE Series sub station LANPWR POWER PT Note: Contact rated at 30V, 1A. 1.Load the software onto the PC to be used as a master station. Insert the CD (included with IPW-1A) or download the latest version from the Aiphone website (www.aiphone.com). 2.Install the CommuniCenter software by following the on-screen prompts, or by executing “setup.exe” to begin the installation process. 3.IPW-1A adaptors within the same broadcast domain as the PC will appear in the sub station location list. Consult the CommuniCenter Operation manual document for further software functionality and configuration information. NOTE – If installing system over a WAN please refer to the CommuniCenter Operation manual. 3 CommuniCenter SOFTWARE INSTALLATION 4-11/16 4 1-5/8 * IN0 IN1 NO C NC
Pg. 3 4 STATION SET-UP DHCP Enabled: · An IP address will automatically be assigned to each IPW-1A with the default ID# as 0 and Location Name left blank. · Right click on each station to open the drop down box, and select Settings. This will open the Hardware Configuration tool. Give each adaptor a unique ID# along with a unique Location Name. · It is recommended that a password be set for each adaptor. This password can be the same for all adaptors in the LAN if you wish. To set the password, right click on the device and select Launch in browser. Under Security Settings, enter a password of your choosing in the Set Password field and select Apply. Once set, this password must be entered before any changes can be made in the Hardware Configuration tool, or web interface. RED and GREEN LEDs next to RS-232 Serial Port Unit powering up: · While the unit is searching for its IP address, the Red LED and Green LED will blink alternately. In the absence of a DHCP server any network activity during this time should allow it to get an IP address, such as opening a web browser. · Upon finding its IP address, the IPW-1A will use SonicIP to verbally announce that address. At this time the Red LED will blink. · If an error is detected, the Red LED will remain on, then the Green LED will blink three or five times depending on the error. Upon blinking the error message, the unit will reset itself. It will blink five times if the firmware is corrupt or if there is an IP address conflict. It will blink three times if the network hardware could not be initialized, or if there is a corrupt MAC address. 5 HARDWARE DIAGNOSTICS
Device running / normal operation: · During normal operation, the Green LED will remain on while the Red LED will remain off. Pushing the reset button: · Upon pressing the reset button, the Green LED and Red LED will remain on. If the reset button is held for 10 seconds or more, the Green LED will remain lit and the Red LED will blink, resetting the unit to factory defaults. Ethernet jack LED status Yellow:link is established Green:connected to 10Mbit network Orange: connected to 100Mbit network 6 SPECIFCATIONS WARRANTY Aiphone warrants its products to be free from defects in material and workmanship under normal use and service for a period of one year after delivery to the ultimate user. We will repair free of charge or replace at no charge Aiphone product, that upon examination by an Aiphone Repair Technician is proven defective and under warranty. Aiphone reserves the right to make the final decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty.This warranty covers bench repairs by the Aiphone Service Department only, and does not extend to units that have been repaired or altered outside of the factory. Aiphone is not responsible for any costs incurred involving on-site service calls. This warranty shall not apply to any Aiphone product that has been subjected to misuse, neglect, accident, power surge, or used in violation of instructions furnished. Hardware Specifications: Input Voltage: Use Aiphone PT-1211C (included); 15-24V AC/DC Network Interface:10/100 Base-T Ethernet (Auto detection) RJ-45 IP Assignment: Static or Dynamic Hardware Protocols:TCP/IP, UDP, DHCP, SNMP, AutoIP, SonicIP, Ipzator Contact Aiphone for additional supported protocols Transport Bandwidth:≈128Kbps per active session (normal mode) ≈64Kbps per active session (low bandwidth mode) Audio Encoding:PCM (raw), G.7II (mLaw) Audio Sampling:16bit at 8kHz (normal mode) 8bit at 8kHz (low bandwidth mode) Output Level: Determined by sub station Relay Contact Rating:30V AC/DC 1.0A (resistive) Operating temperature: 32°F to 104°F (0°C to 40°C) Dimensions:1-1/2″H x 4-1/4″W x 4-15/16″D Software System Requirements: For optimum performance of the CommuniCenter program, we recommend the following minimum requirements: Operating System:Microsoft Windows XP (SP2), Windows Vista Processor:1 GHz or faster Memory:256MB of RAM Hard drive:50MB of available disk space Sound Card:Windows supported sound card (w/ speaker & microphone) ®® Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071 TOLL FREE TECHNICAL SUPPORT: (800) 692-0200 E-MAIL: [email protected] Pg. 4 IPW-1A Instr. 0211DM