Home > Aiphone > Telephone > Aiphone GTVAX Instructions User Manual

Aiphone GTVAX Instructions User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Aiphone GTVAX Instructions User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 161 Aiphone manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							- INSTRUCTIONS -
    The GT-VAX is a video module that provides a connection for up to 2 external CCTV cameras for viewing 
    the area surrounding the GT entrance panel. When a visitor calls from the entrance station, the view from 
    the separate CCTV camera will be seen on the tenants monitor station. The tenant has the option to switch 
    over to a second CCTV camera (if equipped).  The GT-VAX module will be installed in the entrance panel, 
    but will not be seen. 
    CCTV Interface Module for GT Multi-Unit Video Entry System
    WIRING DIAGRAM:
    ENTRANCE PANEL CONFIGURATION:
    1. The GT-VAX module takes the place of the standard GT-VA module, and must be located in the entrance 
    panel. 
    2. A blank plate (GF-BP) is required to cover the GT-VAX, so it will be out of sight from the outside of the 
    panel. 
    3. The remote CCTV camera (powered locally) connects to the back of the GH-VAX module as shown 
    below. The camera location is intended to provide a wider view of the lobby or entry area, other than a 
    direct frontal view of the visitor.
    4. Build the remainder of the GT entrance panel in the same manner as any other GT station, with the GT-
    DA-L Audio Module connected directly with the GT-VAX, then all other modules connected as 
    designated in the GT Installation & Operation Manual. 
    5. Programming and operation of the GT entrance panel when using the GT-VAX CCTV interface module is 
    the same as a standard GT panel. 
    A1 A2
    Black wire 
    (video in, ground)Yellow wire
    (video in, +)
    GT-VAX w/ GT-DA-L
    (rear view)CCTV Cameras
    (powered locally)
    CoaxGT-VAX:
    This unit is used in place of a standard 
    GT-VA, so there is no camera built into 
    the entrance panel. The only video is 
    from the external CCTV camera(s).
    Video wire #871802
    R1 R2 ELB ELC ELM BP BP
    CN2
    CN1ONSW21234VR1
    Audio wire #872002
    GT-VBC
    +-
    GT-BC
    -+-
    Distribution 
    PointR1/R2 to 
    Tenant
    PS
    B1/B2 to 
    Tenant
    To GT-SW 
    or GT-NS
    1011
    ON
    1234SW3CN6
    ON
    1234SW1CoaxBrown wire
    (video in, +)
    Red wire 
    (video in, ground)
    Default Camera
    Secondary Camera
    If only using 1 CCTV camera, 
    connect it to the Yellow and Black 
    wires.  The secondary camera to 
    the Brown and Red wires will be 
    used if you desire another camera 
    in the lobby area and the ability to 
    switch between the two cameras. 
    						
    							To GT-BC
    (see GT Installation Manual)
    Audio/Data wire 
    #872002
    To GT-VBC 
    (see GT Installation Manual)
    Video wire #871802
    Aiphone Communication Systems
    1700 130th Ave. N.E.
    Bellevue, WA  98005
    (425) 455-0510
    FAX (425) 455-0071GT-VAX Instr.
    1011JD
    SPECIFICATIONS:
    Power Source: Supplied from GT-VBC
    Video Input: 1V peak-to-peak, 75 ohm (composite video)
    Mounting: GT-VAX video module mounts inside GT entrance panel in place of standard GT-VA module
    Use GF-BP blank panel to cover the GT-VAX module
    Temperature: 32°F ~ 104°F (0°C ~ 40°C)
    Terminations: Color-coded prewired pigtails, connector, and tension terminals
    Wiring: 2 conductor, non-shielded, solid wire from GT-VBC. Use Aiphone 871802 wire. 
    Wiring Distance: 980 from GT-VBC
    Dimensions (HxWxD):
    3-5/8 x 4-1/4 x 2
    NOTE: Only information concerning the GT-VAX is shown here.  For complete system installation, please refer to the 
    GT installation manual.
    OPERATIONS:
    1. Visitor comes to Entrance panel and calls tenant. (See standard operational instructions.)
    2. Video image will come from the remotely located CCTV camera, and will be present on the tenant monitor 
    only when the entrance panel is engaged, or when a tenant selects that entry to be viewed. If full time 
    video is required from that camera, alternate connections are required. 
    3. Use the guard key on the tenant station to switch between cameras attached to the GT-VAX (if equipped).
    Note:  Monitor mode functionality (of a entry station or GT-VAX in stand-alone configuration) is of the lowest 
    overall priority and will be overridden by any other system communications or calling function.
    AIPHONE
    OPTIONAL CONFIGURATION (Stand-alone CCTV Adaptor):
    1. GT-VAX can be used as a stand-alone CCTV adaptor if system capacity allows it. This station will count as 
    1 of the 16 entrance panels allowed in the system.  No programming is required at this entrance.
    2. Stand-alone camera panel should be comprised of (1) GT-VAX, (1) GF-BP, (1) GT-DA-L, (1) GT-DP, (1) 
    GF-2F.  Either GF-2B (semi-flush) or GT-102HB (surface mount) should be used for mounting the 
    hardware.
    3. The dip switches on the GT-DA-L associated with the GT-VAX must be set as a separate entrance panel 
    from any other entrance panel in the system.  It is recommended that these dip switch settings be adjusted 
    with the power on the GT-BC and GT-VBC turned off.  If the dip switch settings are changed with power 
    applied, you must recycle power to the GT-BC and GT-VBC prior to the changes taking affect.  
    Note: Dip switch 1 on the GT-DA-L must be on to enable the monitoring feature from the tenants.  
    Refer to GT instructions, Section 5-18.
    4. Video image will come from the remotely located CCTV camera, and will be triggered on only when the 
    stand-alone panel is engaged. This occurs when a tenant cycles through the entrance stations by pressing 
    the KEY button (sequentially) when the system is in standby mode. (If a visitor calls from an entrance 
    station, tenant viewing will be cut off). 
    CCTV Camera
    (powered locally)
    coax
    GT-VAX with GT-DA-L
    (Used as CCTV camera adaptor)
    TOLL FREE TECHNICAL SUPPORT:
    (800) 692-0200
    E-MAIL: [email protected] 
    						
    All Aiphone manuals Comments (0)