83435300 05950 AlPHONE TD Series DOOR STATION ADAPTOR INSTALLATION & OPERATION MANUAL SYSTEM OUTLINE & COMPONENTS DE-UR is an adaptor that can add a door station, audio or PanTilt video to TD Phone Selective Call Intercom. IF-DA @- IF-DA 5(+,-,D and two C) to TD-H(or TD-Z) stations A position, preset Set to B position Package contents Packet of screws Installation & Operation Manual *TD-H or TD-Z system is powered by a PS-12A (PS- 12C), which should be located in the middle point of cable run. Install a DE-UR(s) near the power supply. Components available * Intercoms TD-H Series: TD-3H/B, TD-6H/B, TD-I 2H/B & TD-24H/B. (TD-H/A Series also) TD-2 Series: TD-6Z/A & TD-I2Z/A loop-wired. Audio door station only. 0 Intercom 0 Audio door stations 0 Video door stations TD-6HIB TD-12UA IF-DA Others : IE-FY (not available in USA) Others : MY-DG, MY-EA It can be a combination of MY-CA (in MYW-CA enclosure) and IF-DA. NAMES AND FEATURES Call tone selector For TD-H to have 2 door stations, DE-UR employs a switch (preset to A) to change slow intermittent tone to faster intermittent tone. Features * Surface-mount with 83.5mm, 3-5/16 guide. * Call tone modulating circuits, 2-1/2-sec. timed. * Powered by using systems PS-I 2N12C power supply. * Includes door release control terminals. Front case screw -1-
PRECAUTIONS ON INSTALLATION & WIRING A CAUTION * Do not connect any terminal on any unit to AC power lines. * Unplug all power supplies while making wiring connections on any audio and video equipment. * DE-UR is an adaptor for indoor installation only. Follow precautions as stated in the Manuals packed with * Locate DE-UR unit(s) closely to power supply PS-12A (PS-12C) of TD-H or TD-Z system, so as to be fed DC12V * Wiring to EL-9S door release must run in a separate jacketed cable and apart from intercom wiring. TD-H and MY-CU monitor. from it. Before installing DE-UR, the contents of this Manual must be thoroughly read and understood. WIRING Terminal block layout +, -: 1, 2: C: D: EL, EL: 12V DC power Door station connection Selective communication from TD-H/TD-Z masters Call-in tone to TD-H masters (or TD-Z) Dry closure contact for door release DE-UR & power supp.: IocaLJn It is suggested to mount a DE-UR unit(s) in a recessed area, together with power supply PS-12A (PS-12C) and video adaptor, etc. Select a location that allows limited access only by qualified personnel, and is dust-free environment possible. Audio door station k EL-SS, AC trans. AC PanTilt video door station /- 4 to TD-H AC trans AC AC -2- 2 PanTilt doors plus 1 camera 6 to MYH-CU (r 5 to TD-H -UR PS-12Aor PS-12c camera AC AC AC trans
Wiring (door 1) 1. One audio IE/IF Series T Rp 2. Two audio IE/IF Series DE-UR DE-UR IF-DA IF-DA 1 2 DE-UR IF-DA I no no 7 PS-12A (PS-12C) 4 wires to (max. 12) to TD-H(TD-2) PS-12A (PS-12C) 5 wires to to TD-H(TD-2) 4. Two PanTilt MY Series 3. One PanTilt MY Series (plus one audio) MY-CU MY-DC to PanTilt 1 to PanTilt 2 TO MY-Ck (camera PS-18D 27 DE-UR DE-UR -0 IF-0 1- (door2) :E I I DE-UR PS-12A DE-UR TD-H (max. 12) 4 I to TD- (for MY-DC) (IF-DA) -3-
MOUNTING DE-UR DE-UR chassis, after separated, mounts with 83.5mm, 341 6 guide. DE-UR DE-UR 1. Opening the cover, loosen the bottom screw. 2. Lift front case off the prongs of chassis, and disconnect DE-UR. 3. Mount the chassis to wall or board at 2 points. 4. Make wire terminations for each door station, TD-H station, and PS-l2A(12C) power supply. 5. Reconnect and mount DE-UR front case to chassis. Diameter Distance AWG Distance Pronas 0.65mm 0.8mm 1 .Omm 1 Om 15m 20m 22AWG 20AWG 18AWG 30 50 65 3 -~ _L 83.5mm (3-5/16) -Chassis Distance S P E C I F I CAT1 0 N S * Power source: * Current consumption: 120mA max. * Call tone: DC 12V, supplied by a power supply PS-12A (PS-12C) of TD-H (TD-Z) system. Intermittent tremolo, 2-1/2-timed 150m I 230m I 360m * Wiring: Distance I To audio IE/IF door I 2 conductors laarallel) I 500 I 750 I 1,200 1 To TD-H/B stations 1 4 conductors (D, C and + , -) 1 * Wiring distance: From DE-UR to door station I Diameter 1 0.65mm I 0.8mm I 1 .Omm Ill1 }to TD-H * DE-UR EL, EL terminals capacity: * Dimensions: (H x W x D) 160 x 150 x 45 (mm). 6-1/4H x 6W x 1-3/4D * Weight: DC 30V, 1A or AC 30V, 1A. 320g (0.71 Ibs.) approx. -4- 4 4 WARRANTY 4 % 4 4 $ 4 4 4 4 4444444444444444444444444444444444444444444444444444444444444~ Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover batteries or damage caused by batteries used in connection with the product. This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone. Aiphone will not be responsible for any costs incurred involving on site service calls. Aiphone Co., Ltd., Nagoya, Japan Aiphone Corporation, Bellevue, WA, USA DE-UR-I(E) 0595E T 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 44 g KlMU$fiOSKC HOME BUSINESS INDUSTRY Printed in Japan (E) -4-