    The C-123LW Dual Master ChimeCom set provides chime, communication, and door relea\
    se for one door and two 
    inside locations. This supplemental instruction manual addresses many of the additional functions and modifications for 
    the Chime Com system, including installation and troubleshooting informa\
    tion.
    C-123LW Supplemental Instructions
    Dual Master ChimeCom System
    - REFER TO INSTALLATION MANUAL INSIDE C-123L/A BOX FOR STANDARD  INSTALLATION INFORMATION -
    MASTER STATION:
    C-ML/A:   Master station with door release button (Normally Open)
    COMPATIBLE DOOR STATIONS: (Weather resistant, made for outdoor use)
    C-D    Surface mount, included in C-123L/A and C-123LW kit
    LE-D   Surface mount, plastic door station (replacement for C-D)
    LE-DA     Flush mount in 2-gang box, stainless steel cover
    LE-SS-1G  Vandal resistant, 1-gang flush mount, stainless steel
    LE-SS/A    Vandal resistant, 2-gang flush mount, stainless steel
    LE-SSR    Vandal resistant, 2-gang flush mount, stainless steel, red mushroom button
    LS-NVP/C  Vandal resistant, 3-gang flush mount, white powder-coat finish
    OPTIONAL COMPONENTS & ACCESSORIES:
    RY-AC/A   External signaling relay (Requires 12VDC power supply)
    DAK-2S    Dual master adaptor kit (2component modules)
        (1 kit per 2 master stations. Use 2 DAK-2S for up to 4 total master stations)
    SBX-1G    Surface mount box for LE-SS-1G
    SBX-2G    Surface mount box for LE-SS, LE-SSR, LE-DA
    SBX-NVP  Surface mount box for LS-NVP/C
    EL-12S    Door strike (for interior wood frame doors only)
    PT-1210N  AC 12V Transformer (used for door strike)
    SKK-620C   6V DC power supply (1 per C-ML/A master)
    822202    2 conductor, 22AWG, Shielded wire for up to 245’, (500’ and 1000’ boxes)
    821802    2 conductor, 18AWG, Shielded wire for up to 590’, (1000’ box)
      Install two separate runs of this cable, one for the intercom and one fo\
    r    
        the door release.
    DOOR RELEASE WIRES MUST BE IN A SEPARATELY JACKETED CABLE FROM THE INTERCOM WIRING.
    C-123LW Set contains:
    2 C-ML/A, 1 C-D, 1 DAK-2S
    Power source and Door Strike not included.
    2 cond. shielded for intercom
    C-123L/A Set
    LE-SS-1G LE-DA
    LS-NVP/C
    LE-SS
    DAK-2S
    (2 component modules per kit)
    Separate 2 conductor for door release
    C-D C-ML/A
    SKK-620C
    Power 
    Source 
    for Strike(or 4 “C” batteries installed in 
    the master). Do not use both 
    power sources.  Ground wire 
    must be tied to earth ground 
    when using the SKK-620C.
    IMPORTANT: Connect wires  before applying power.
    EL-12S, not included with the C-123L/A or C-123LW set.       
    						
    							Please read and understand all 
    instructions before installation.
    IMPORTANT:  Connect wires before applying power.
    SKK-620C SKK-620C
    SKK-620C SKK-620C
    C-123LW Supplement
    Pg. 2 WIRING DIAGRAM: Dual Master Chime Com System with DAK-2S Dual Master Adaptor
    OPERATION NOTES:
    1.  Only one master can be used at a time.
    2.  If both masters are activated, a feedback (squeal) will be heard t\
    hrough the system when either TALK button is pressed.
    3.  If feedback occurs, wait approximately 15 seconds, or until the mast\
    ers turns off automatically.  At that time,  
         communication can continue normally.
    INSTALLATION GUIDELINES:
    1.    Run 2 conductor wire from the door station to the first master, then continue to the second master.
    2.    Install the units at the desired locations. (Do not install stati\
    ons back to back on opposite sides of a wall.)
    3.    Separate SKK-620C power supplies or four “C” batteries are required for each master station. 
    4.    DO NOT install both a power supply and batteries at any one master.
    5.    Install the bare wire leg of the component module directly onto th\
    e “1” terminal of the C-ML/A’s. 
    6.    Attach the wire coming from the “1” terminal of the C-D to the col\
    ored wire end of the component modules at both masters. (The component
           modules will easily fit inside the space available.)
    7.    Connect the “E” terminals between the door station and maste\
    r stations.
    8.    If door release is included, use a separate 2-conductor wire from \
    the “L” terminals of the masters through an AC transformer and to the door strike.
    9.    The EL-12S is designed for a standard wood framed door, and for light to medium usage. If a different type of door is in place, install a strike 
           appropriate for the door.
    10.  The door release button on the master station is a “Normally Open” contact closure for an electric strike. See page 3 for modification to “Normally 
           Closed” if a magnetic lock is used.
    IMPORTANT!!!
    Each master 
    REQUIRES an SKK-620C power supply, or 4 “C” batteries.
      (Do not install both on one C-ML/A.)
    1
    E E
    - 1
    L
    L +
    E
    - 1
    L
    L
    +
    4 C-ML/A Master Stations with 1 Door
    Note: In a multi-master system, all masters only talk to the 
    door station, and only one master can be on at a time
    C-D C-ML/AC-ML/AC-ML/A
    C-ML/A
    Component 
    Module Component 
    Module Component 
    Module Component 
    Module
    C-D C-ML/A
    SKK-620C C-ML/A
    SKK-620C
    Component  Module* Component 
    Module*
    EL-12S
    1
    E E
    - 1
    + E
    - 1
    + 1
    E
    - 1
    +
    E
    -
    +
    * Install bare wire end to the “1” terminal
    (DAK-2S contains two component modules)  
    						
    							1
    E
    E
    - 1L
    L
    + -RY-AC/A
    BELLSKK-620C
    IMPORTANT:  Connect wires  before applying power.
    C-123LW Supplement Pg. 3
    WIRING DIAGRAM: LEM-1DL System with External Signaling using RY-AC/A Relay
    +
    MODIFICATION INSTRUCTIONS: 
    C-ML/A with Door Release contact Modified to Normally Closed (for Magnetic Lock)
    Normally Open Dry  Contact to door 
    strike and powerComponent Module*
    If a DAK-2S is not available, install components as shown below.
    Capacitor: 25V, 15-33ufd Non-polarized
    Diode: 1N4148 Output of RY-AC/A (Yellow 
    wires) provide a momentary 
    dry contact closure while 
    the call button on the door 
    station is being pressed.
    12V DC power 
    supply
    NOTE: Negative of 
    power supplies must be 
    tied together.
    C-ML/AComponent  Module*C-D
    White
    Red
    Black
    Power source for bell
    To 1 of C-D and WHITE 
    wire of RY-AC/A To 1 of C-ML/A
    Magnetic locks require Normally Closed 
    contacts, keeping power applied to the 
    magnet to keep the door locked, and 
    breaking power to release the door. These 
    instructions explain how to change the 
    contact in the C-ML/A to Normally Closed.
    1.  Remove back chassis of C-ML/A 
         and move the PC-754 board aside.  
         Black door release switch will be visible.
     
    2.  On the switch, move* the wire from 
         the NO contact (middle position) to 
         the NC contact (top position).  
         *Desoldering and resoldering is required.
     
    3.  This modification will change the 
         door release button’s function to 
         Normally Closed, to be used with 
         magnetic lock device. 
    4.  Switch contact rating is 1A at 50V AC.
    +
    -
    60H- 2A
    8
    THA1547
    Door releas e
    switch
    COM NONC
    C-ML/A Rear View with PC board removed. 
    						
    							INSTALLATION TIPS:
    1.  Use shielded wire for the communication path, and ground one end of \
    the shield to an earth ground.
    2.  Run intercom wire at least 20” away from AC wiring, fluorescent lights or dimmer switches. 
    3.  Keep intercom cable away from alarm, data, phone, video cables, and \
    any other potential source of 
         interference.
    4.  Door release wires must be in a separately jacketed cable from the i\
    ntercom wires. Use two separate                
         cables; one for audio and one for door release.  
    5.  When installing a second master station, wire must be run from the first master station, not from the          
         door station. See diagram on page 2. 
    6.  Do not install the master station near light switches, dimmer switch\
    es, or other devices that may cause    
         interference with the intercom system. 
    7.  Do not install the master station on the opposite wall from the door\
     station. If the units are too close,          
         acoustical feedback may result.
    TROUBLESHOOTING GUIDE:
    Aiphone Corporation
    www.aiphone.com
    [email protected]
    (800) 692-0200C-123LW Supplement Pg. 4
    #90102 0816
    PROBLEM POSSIBLE CAUSESOLUTION
    No call in from door to master, but 
    communication works fine. Reversed DAK-2S component module.When door calls in, it shorts the #1 terminal to the E terminal.  
    If the DAK-2S is installed backwards the chime from the 
    door call-in will not be heard.  Install the DAK-2S component 
    module with the bare wire under the 1 terminal, and the door 
    station 1 wired to the colored wired end of the DAK-2S.
    When the talk button is pressed, the other 
    master rings. Missing or reversed DAK-2S 
    component module.Install the DAK-2S component module as described above 
    and shown on the dual master instructions.
    When the talk buton is pressed, feedback is 
    heard at both masters. Common power supply.If both C-ML/A’s share the same power supply, a ground loop 
    feedback will occur when the talk button is pushed. Install a 
    separate power source for each master.
    Unit appears dead; No functionality Terminals 1 and - crossed+/- are on left column, E/1 are on right column. If swapped, 
    unit will appear dead. Verify that 1 from the door station is 
    connected to 1, and negative of power supply is connected to -.
    System squeals and batteries get hot Power supply and batteries both 
    installed.Take batteries out of the master station. Both power sources 
    cannot be used simultaneously.
    Chime tone sounds weak, low frequency Weak batteries or low voltage.If batteries are installed, replace them. If using a power supply, 
    check for 6VDC. If low, install a new SKK-620C.
    Master stays on; does not time out. Incorrect cable being used.
    Volume control not adjusted properly.
    Standard volume level.If the resistance of the wire is too great, usually from 
    exceeding distance limitations, the master may not time out as 
    designed. Refer to wire specifications in the instructions.
    Remove front cover of the C-ML/A and locate volume 
    potentiometer through hole at bottom of unit. Use a small 
    screwdriver to adjust the volume, clockwise to increase.
    There is not a separate call tone volume adjustment on the 
    C-ML/A so the volume level cannot be altered. Surface mount 
    component level modification would be required, which is not 
    paractical.
    RY-AC/A external signaling relay not working. Missing or wrong connection.
    Make sure the negative from the 12VDC supply for the RY-AC/A 
    is connected to the negative of the C-ML/A master. Make sure 
    the WHITE wire of the RY-AC/A is connected to the DAK-2S 
    component module to terminal 1, not negative terminal.