Home > Aimco Brakes > Screwdrivers > Aimco Brakes Screwdriver TM45 65 Quick Start Guide

Aimco Brakes Screwdriver TM45 65 Quick Start Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Aimco Brakes Screwdriver TM45 65 Quick Start Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 85 Aimco Brakes manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Quick Start for 
    TM-45 and TM-65 Fastener Counter  PO Box 16460, Portland, OR 
     97292-0460   503-2 54-6600   Fax 503-255-26 15
    1. Attach black power cord to rear of Electra TM box.
    2. Plug into 110VAC power.
    3. Plug WORK I/P Plug (p lastic stem with connector) into  “Work I/P”
    receptacle on back of Electra TM sy
    stem.
    4. O
    
    n front of TM box,  attach Electra Screwdriver power cord into
    receptacle on lower-right 
    side.
    5. Turn
    
     power on to TM system (will also power Electra Screwdriver).
    6. Press “Set” button on front of the Electra TM system.
    7. Password will be requested. Press keys in this combination “+ + - -  SET 
    DETECTOR”.
    8. Press
    
     “SET” three (3) times
    .
    9. On
    
     screen  3-1.SAMPLE TIMES , use “+” or “-” keys to scroll up or down to desired number of sample r
    uns
    that
    
     will be used to set up the system. The larger the number, the more accurate the sampling will be and 
    the
    ti
    
    ghter the tolerance  on the box can be  set. Twelve  (12) is a good place to start. Press “SET” when the 
    desired
    nu
    
    mber i s on the scree
    n.
    On
    
     screen  3-2.SAMPLES
    ,
      it will display 0/xx with ‘xx’ being the number of samples from th e previous screen.
    Be
    
    gin t he sample  gathering by running the Electra Screwdriver exactly as the operator will on a 
    production
    quality application. At the end of each rundown, the Electra TM system will request an entry of the “+” key if
    the sample ran as expected with no known problems or an entry of the “-” key if the  sample run had an  operator
    error or some other difficulty. Repeat this process until ‘xx’ number of good samples has been recorded based
    on ‘xx’ being the number of samples desired (xx/xx). Hit “SET” to complete.
    10. On screen  4-1.RANGE RATE , use the “+” or “-” keys to adjust the value to the + tolerance of the assembly
    task. Be sure to take the application dynamics into account as the material variances will contribute to how accurate the assembly  job can be  performed. A good strategy is to start at +10% and then adjust as the product
    quality sampling dictates. Hit “SET” to complete.
    11. On screen  4-2.RANGE RATE , use the “+” or “-” keys to adjust the value to the - tolerance of the ass embly
    task. Be sure to take the application dynamics into account as the material variances will contribute to how accurate the assembly  job can be  performed. A good strategy is to start at +10% and then adjust as the product
    quality sampling dictates. Hit “SET” to complete.
    12. On screen  5.PCS/UNIT, use the “+” or “-” to select how many screws per work piece are to be monitored. If
    the operator is installing four (4) screws into a phone, for  example, then this screen shoul d be set at four (4).
    The unit will then count how many good phones pass through the station. Hit “SET” to complete.
    13. Press “DETECTOR” and the system will be ready to run and monitor fastening.
    14. For a dditional options and detailed descriptions of each menu screen, please see the Electra T M Instruction
    Sheet packaged with the Electra TM system.