    UL Series Fill & Draw Sheet 
     
    Key Model of this  
    Tool Group 
     
    Full Volume 
    of Liner Oil 
    in Pulse Unit 
    (approx.) 
    Volume to be 
    Removed from 
    the Full Volume 
    (approx.) 
    Torque to 
    Tighten Liner 
    Casing Setter 
    (approx.) 
    Torque to 
    Tighten Liner 
    Casing Setter 
    (approx.) 
    Load to 
    Press on 
    Rear Liner 
    Plate 
    Load to 
    Press on 
    Rear Liner 
    Plate 
         Hydraulic Press P.T.R.F. 
    Model cc’s cc’s NM Ft-Lbs Tons Ft-Lbs/Nm 
    UL-30(D) 5.0 0.31+/-.01 85+/-5 63+/-4   
    UL-40(D), UL-40A(D)MC 5.0 0.35+/-.01 85+/-5 63+/-4 1 20/27 
    UL-50(S)(D) & 50(D)MC,  
    UL-40(D)MC, UL-50A(D)MC 5.0 0.45+/-.05 85+/-5 63+/-4 1 20/27 
    UL-60(S)(D), 60MC, 60AMC 6.8 0.55+/-.05 85+/-5 63+/-4 1 20/27 
    UL-70, UL-70MC, 70AMC 8.0 0.65+/-.05 110+/-5 81+/-4 2 40/54 
    UL-80 14.0 0.80+/-.05 110+/-5 81+/-4 2 40/54 
    UL-90, UL-90MC, 90AMC, 
    900AMC 14.0 0.95+/-.05 150+/-5 110+/-4 3 60/81 
    UL-100 19 1.50+/-.05 185+/-10 137+/-7 3 60/81 
    UL-100MC, 100AMC 21.5 1.60+/-0.1 185+/-10 137+/-7 3 60/81 
    UL-130 27.0 1.70+/-0.1 185+/-10 137+/-7 3 60/81 
    UL-130MC, 130AMC 24.0 1.60+/-0.1 185+/-10 137+/-7 3 60/81 
    UL-150 36.6 2.60+/-0.1 200+/-10 148+/-7 3 60/81 
     
     
     
     
      
    UL Series Troubleshooting 
     
     
    Troubleshooting 
     
     TROUBLE CAUSE SOLUTION 
    Low Torque 
    Air motor dry; no lubrication Lubricate the air motor. 
    Loss of power in the air motor Reset the air motor. 
    Low oil in the pulse unit Add .10cc of oil and/or re-tank the 
    pulse unit. 
    Low RPMs 
    Exhaust filter dirty Replace the filter in the silencer. 
    Air motor dry; no lubrication Lubricate the air motor. 
    Loss of power in the air motor Reset the air motor. 
     
     
    Recommended Preventative Maintenance 
     
    It is recommended that after every 200,000 pulsing seconds or 180 days, the fluid in the tool’s pulse unit be 
    changed. At such time, it is also recommended to grease the bearings in the air motor. If the presence of water is 
    noted, it is recommended that a small amount of oil be run through the air motor to wash out any rust residue in 
    the air motor. 
     
    It is also recommended that after every 400,000 pulsing seconds or 365 days, that a Pulse Unit Repair Kit be 
    installed in the pulse unit. This also allows the inspection of hard parts in the pulse unit. 
     
      
    						
    							 
          
     
     AIMCO CORPORATION DE MEXICO SA DE CV AIMCO EUROPE  Ave. Cristobal Colon 14529 C/ Rio Gallo, 431 urb. Montelar  Chihuahua, Chihuahua.  31125 19174 Galápagos / Guadalajara  Mexico Spain  Phone: (01-614) 380-1010 Phone: + 34 673 34 99 25  Fax: (01-614) 380-1019     AIMCO CHINA AIMCO SOUTH AMERICA CORPORATE HEADQUARTERS Room 607, No. 3998 Hongxin Rd  Carrera 29A, #7B-91 Origami Building Int604 10000 SE Pine Street Minhang District, Shanghai  Medellin; Colombia 050021 Portland, Oregon  97216 China  Phone: (503) 254-6600 Phone: 0086-21-34319246  Toll Free: 1-800-852-1368 Fax: 0086-21-34319245  