Page 11

PAGE 9 OF 16 
NOTE:  THE TORQUE REGULATOR WILL NOT GIVE FULL CONTROL OVER THE ENTIRE 
RANGE OF THE TOOL. THE RANGE OF TH E REGULATOR IS FROM FULL TORQUE TO 
APPROXIMATELY 50% OF FULL TORQUE VALUE. 
TIP:  If a lower torque level is required it may be achieved by reducing the m\
ains air pressure to the tool.  NOTE
: REPEATABILITY OF THE TOOL MAYBE AFFECTED BY THE U SE OF THIS 
REGULATOR.  
IMPORTANT:  IF RUNNING THE TOOL WITH LUBRICATION, CHECK THAT THE LUBRO 
CONTROL UNIT IS SUPPLYING APPROXIMATELY SIX...

Page 12

PAGE 10 OF 16 
OPERATING INSTRUCTIONS 
WARNING:  KEEP HANDS CLEAR OF THE REACTION ARM. 
WARNING:  WHEN USING THIS TOOL IT MUST BE SUPPORTED AT ALL TIMES 
IN ORDER TO PREVENT UNEXPECTED RELEASE IN THE EVENT 
OF   FASTENER OR COMPONENT FAILURE. 
A. TIGHTENING ____________________________________________________________
1. Fit Pneutorque® with the correct size impact or high quality socket t\
o suit fastener.
2. Ensure the Clockwise/Counter-clockwise Selector is correctly set (if fitted).
3. Rotate the...

Page 13

PAGE 11 OF 16 
B. RELEASING _____________________________________________________________
NOTE:  ONLY FOR BI -DIRECTIONAL TOOLS 
1. Fit the Pneutorque® with the correct size impact or high quality sock\
et to suit the fastener to be
released.
2. Ensure the clockwise/counter-clockwise selector is correctly se t.
3. Rotate the handle into a convenient position relative to the reaction ar\
m.  Fit the tool onto the
fastener to be released with the reaction arm adjacent to the reaction p\
oint.  See Figure...

Page 14

PAGE 12 OF 16 
MAINTENANCE 
To maintain optimum performance and safety, regular maintenance needs to be carried out.  The only 
user maintenance required on these tools is the replacement of drive squ\
ares and the silencer.  Any oth er 
maintenance or repairs should be carried out by Norbar or a Norbar appro\
ved agent and should form part 
of a service.  Service intervals will depend on the type of usage of the\
 tools and the environment in which 
they are being used.  
AIR LUBRICATION:...

Page 15

PAGE 13 OF 16 
DRIVE SQUARE :-____________________________________________________________  
To avoid internal damage (especially due to torque overload), the outp\
ut drive square has been designed 
to shear first.  This saves major internal damage and allows  easy square removal.  Figure 
10 
The drive square can be replaced with either a ¾” drive square (#\
18544), or a 1” drive square (#18545). 
A new retaining screw (#25351.30) is supplied with the square.  
To replace drive square:  
1. Use 3mm...

Page 16

PAGE 14 OF 16 
SPECIFICATIONS 
RANGE  MODEL 
MIN  MAX  MAXIMUM 
OVERLOAD   T
OOL SPEED 
(FREE RUNNING AT MAX. AIR  PRESSURE)   18039 & 18041 
120 N.m 600 N.m  660 N.m   200 r/min  18040 & 18042 
200 N.m 1000 N.m  1100 N .m  125 r/min  Repeatability: 
Air Supply
: 
Recommended L ubrication: 
Temperature R ange: 
Maximum Op erating Humidity: 
Case Materials / Finish :  ± 5% 
Maximum pressure – 6.3 bar (For maximum torque capacity). 
Shell Tellus 
S2 
V  15 for the Lubro Control Unit. 
0°C to +50°C...

Page 17

PAGE 15 OF 16 
Declaration of Conformity  
Manufactured by  Norbar Torque Tools Ltd., 
Beaumont Road, Banbury, Oxon, OX16 1XJ 
The Directives covered by this Declaration 
Safety of Machinery Directive, 98/37/EEC 
The Equipment Covered by this Declaration 
Equipment:  52mm Stall Tool. 
Model No.(s):  18039.F06, 18039.B06, 
18040.F06, 18040.B06, 
18041.F06, 18041.B06, 
18042.F06, & 18042.B06. 
The Basis on which Conformity is being Declared  
The equipment identified above is in compliance with the...

Page 18

PAGE 16 OF 16 
TROUBLE SHOOTING 
The following is only a guide, for more complex faults please contact yo\
ur local Norbar distributor or 
Norbar directly.  
PROBLEM  LIKELY SOLUTIONS Tool output does not rotate
 when trigger pulled. Check air supply is functioning & connected.  
Check air pressure setting (at least 1 bar). 
Check correct setting of direction knob.  
Output drive square sheared, needs replacing.  
Gear train or air motor is damaged  Drive square sheared.
  See maintenance section to...

Page 19

. 

Page 20

LITMAN3\b\b, Rev.5/16Printed in USA
©2\b16 
AIMCO
 AIMCO China
Room 607, No. 3998 Hongxin Rd Dibao Plaza 
Minhang District, Shanghai China
Phone: 0086-21-34319246
Fax: 0086-21-34319245
10000 S.E. Pine St. 
Portland, OR 97216
 
(800) 852-1368
FAX (800) 582-9015  
www.aimco-global.com Corporate Headquarters
AIMCO Corporation
De Mexico Sa De Cv
Ave. Cristóbal Colon 14529
Chihuahua, Chihuahua. 31125 Mexico
+52-(614) 380-1010
FAX +52 (614) 380-1019
AIMCO EUROPE
Avenida Río Gallo, 431
19174 Galápagos -...
Start reading Aimco Brakes DynaTorque Stall Tools Manual

Related Manuals for Aimco Brakes DynaTorque Stall Tools Manual

All Aimco Brakes manuals