Page 1

AUET & AUET/MTM Desktop Torque 
Testers  User Guide
 
PO 
Box 16460,  Portland,  OR 97292-0460
   
  503-254-6600 
   
Fax  503-255-2615 
www.aimco-global.com 

Page 2

2 
CONTENTS  Safety Requirements .................................................................................................................... 4 Descriptions and Specifications Unit Specifications ......................................................................................................................... 4 Screen and Button Diagram ........................................................................................................... 5 Side Panel Diagrams...

Page 3

3 
SAFETY REQUIREMENTS 
SAVE THESE INSTRUCTIONS 
 
1) WORK AREA 
 a) Keep work area clean and well lit. 
Cluttered  and  dark  areas  invite 
accidents. 
 b) Do  not  operate  power  tools  in 
explosive atmospheres, such as 
the  presence  of  flammable 
liquids,  gases  or  dust. Power 
tools  create  sparks  which may 
ignite the dust or fumes. 
 c) Keep  children  and  bystanders 
away  while  operating  a  power 
tool. Distractions can cause you to 
lose control. 
 
2) ELECTRICAL SAFETY 
 a) Power...

Page 4

4 
clothes, jewelry, or long hair can be 
caught in moving parts. 
 g) If  devices  are  provided  for  the 
connection  of  dust  extraction 
and  collection  facilities,  ensure 
these  are  connected  and 
properly  used. Use  of  these 
devices  can  reduce  dust-related 
hazards. 
 
4) POWER TOOL USE AND CARE 
 a) Do not force the power tool. Use 
the  correct  power  tool  for  your 
application. The  correct  power 
tool will do the job better and safer 
at  the  rate  for  which  it  was...

Page 5

5 
SCREEN AND BUTTON DIAGRAM 
Figure 1 
 
 
 
 
 
 
16 
 
 
 
 
 
 
 
 
 
1. Data Display 
2. Operating Mode 
3. Menu Mode Status 
4. Selection Arrow – Down  Change Operating Mode  Scroll Down through Menu screens 
5. Left Selection Button  Menu Mode  Reduce Parameter Value  Select Parameter 
6. NOK Value Indicator LED (RED) 
7. Clear Data Display Value / Manually ZERO Display 
8. Power On 
9. Power Off / Charging Mode 
10. Enter  Set Values  Back up one Menu Screen 
11. OK Rundown / Charging Mode...

Page 6

6 
Figure 2  
       
 
 
Figure 3 
 
AUET/MTM                                                          AUET 
Model                                                                   Model 
           
Transducer 
Selection 
 
Transducer  
Input 
 
AUET/MTM 
Model 
DC Power 
Input 
Serial 
Communication 
Output 
Serial 
Communication 
Output 
DC Power 
Input  

Page 7

7 
OPERATING INSTRUCTIONS 
Selecting the Active Transducer 1. Rotate the Transducer Selection knob (Fig 2.) to select the active transducer. 2. All functions of the AUET/MTM system outlined below will pertain to the active transducer only 3. Active transducer will be shown by an illuminated  LED  lamp  adjacent  to  the active  built-in  transducer, or  no  LED lamp  visible  when  using  a  transducer connected to the external port. 4. Built-in  transducers  are  preset  and ready  for  use  immediately...

Page 8

8 
Preparing the AUET/MTM for Use The AUET/MTM testers feature a supplied Joint  Simulation  Kit (Fig.  A) that  is configurable to a variety of joint conditions.   Fig. A 
  The  Joint Kit is  made  up  of  a  series  of Belleville Washers that allow the user to pre-configure the joint to match the actual application  joint  as  closely  as  possible. Each  of  the Belleville  Washers is concave  in  shape. By  aligning  all  the concave  curves  in  the  same  direction a simulated hard joint is...

Page 9

9 
Selecting the Proper OPERATING MODE While  in  the  Main  Display  screen,  press the Selection  Arrow-Down button  to 
cycle  through  the  available  Operating Mode  choices. The  choices  will  be displayed in the following order:  
   Selecting the Proper DATA MODE The AUET/MTM contains  two Data Modes. RUN and MEMORY.  RUN mode  simply  allows  the  tester  to display  Torque  data  from  the  driving source  immediately  after  rundown  is complete. Data  will  be  displayed  on  the screen...

Page 10

10 
Clearing a Torque Value / RUN MODE 
When  in RUN  MODE,  if Auto  Clear is 
turned on by selecting a time value, the 
display screen will automatically convert 
back  to  a  zero  value  after  the  set 
amount  of  seconds. Auto  Clear clears 
the display  and  sends  the  value  out  to 
the serial port automatically. 
 
When  in RUN  MODE,  if Auto  Clear is 
turned OFF, the operator must manually 
clear a torque value from the display: 
1. Set the Auto Clear function to OFF. 
2. While  in  the...