Aimco Brakes AUET Torque Analyzer Quick Start Guide
Here you can view all the pages of manual Aimco Brakes AUET Torque Analyzer Quick Start Guide. The Aimco Brakes manuals for Torque Measurement are available online for free. You can easily download all the documents as PDF.
Page 1
AUET & AUET/MTM Desktop Torque Testers Quick Start Guide PO Box 16460, Portland, OR 97292-0460 503-254-6600 Fax 503-255-2615 www.aimco-global.com
Page 2
2 See Product User Guide for: Safety Requirements Step By Step Functionality Detailed Operating Procedure SCREEN AND BUTTON DIAGRAM Figure 1 16 1. Data Display 2. Operating Mode 3. Menu Mode Status 4. Selection Arrow – Down Change Operating Mode Scroll Down through Menu screens 5. Left Selection Button Menu Mode Reduce Parameter Value Select Parameter 6. NOK Value Indicator LED (RED) 7. Clear Data Display Value / Manually ZERO Display 8. Power...
Page 3
3 BASIC FUNCTIONS Turning On / Off To turn the AUET & AUET/MTM on, press the “ON” button (Figure 1). The AIMCO logo will be displayed for approximately 4 seconds, then the unit will start at the RUN or sequential MEM mode of the tester. To turn the AUET & AUET/MTM off, simply press the “OFF” button. Set Torque Reading Mode OPERATING MODE Descriptions By selecting the proper Operating Mode, the user can properly take torque readings from a variety of manual and powered tools....
Page 4
4 Sign Lock The SIGN LOCK feature allows the user to select the rotation direction in which a torque peak will be captured. With SIGN LOCK set to ON, the initial first rundown direction is set as the default direction. If the initial rundown was performed in a clockwise direction a positive reading indicates a reading taken in the clockwise direction while a negative torque value indicates a reading taken in the counter-clockwise direction. If the initial rundown is taken in...
Page 5
5 Using the AUET & AUET/MTM in RUN MODE RUN MODE can be used to quickly and easily take torque readings using a variety of tools in situations where storage of data and statistical feedback is not necessary. With the AUET & AUET/MTM turned ON, observe the Data Storage Mode Status field (Figure 1). If RUN is displayed, the AUET & AUET/MTM is in RUN MODE and can then be configured accordingly. If the status reads MEM, then the AUET & AUET/MTM is in MEMORY MODE. Install the supplied driving...
Page 6
6 authorized AIMCO Sales Representative for a transducer upgrade quotation. For the typical, Industry Standard (IS) type of transducer, the setup procedure is as follows: 1. Turn the AUET/MTM On. 2. Within 3 seconds of pressing the ON button, press the LEFT SELECTION BUTTON (Figure 1) for CAL 3. Press ENT to SELECT UNITS. If a transducer has been previously setup, the data for that previous setup will be shown. 4. Units of measure for use in setting up the...