    Have a look at the manual Aimco Brakes AHCTSK Series Hydraulic Wrench Test Stands User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 85 Aimco Brakes manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 
      PROGRAMMING &  NAVIGATION 10 
    AHCTS-K Series User’s Guide 
    3  DATA MENU 
    SEL: Enters menu. 
     
    3-1  Print Memory 
    Send: Prints the currently saved readings. 
     
    3-2  Clear Memory 
    CLR: Followed by ENT clears the readings saved in memory. 
     
    3-3  Reset All 
    CLR: Followed by ENT clears all readings and all sets. Should be used approximately 
    every 5000 readings. 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    2-4 Information 
    3 Data Menu 
    3-1 Print Memory 
    3-2 Clear Memory 
    3-3 Reset All  
    						
    							 
     
    AHCTS-K Series User’s Guide 
     DESCRIPTION OF FUNCTIONS 11 
     
    DESCRIPTION OF FUNCTIONS 
     
    OPERATING MODES 
    Peak, 1st Peak or Track will show on the display.  Press the Œ key to toggle them. 
     
    Peak 
    Recommended operating mode for stall tools. 
    Displays and retains the maximum torque exerted by the tool, as occurs when operating 
    the wrench in the tightening direction.  The Peak Mode is used for all power tools and dial 
    wrenches. 
     
    1st Peak 
    Detects the “first peak” of torque exerted by the tool, capturing the initial torque as occurs 
    when the torque wrench cams over.  First Peak is used primarily for Click Torque 
    Wrenches and cam over screwdrivers. 
     
    Track 
    Displays torque as it is being applied to the transducer.  Track mode is used primarily for 
    verifying calibration of the unit. 
     
    E
    NGINEERING UNITS 
    Shows the current engineering units.  Press the  key  to  cycle  through  the  eight 
    possible choices: Kgf m, KgfCm, gfCm, cNm, Nm, FT LB, IN LB, IN OZ. 
     
    FULL SCALE 
    Shows the Full-Scale value of the Torque Shaft.  This is not an adjustable value. 
     
    LOW LIMIT 
    Use the Low Limit setting to visually flag the operator when a reading fails to reach a 
    desired minimum value. A small down arrow will appear on the screen if a peak is 
    captured below the limit setting. 
     
    The limit is adjusted by using the navigation buttons to set the first four digits to the 
    desired value.  The fifth digit is used to select the decimal point position.  The Up and 
    Down buttons under the “Soft” button Change will change the value from 0-9.  Pressing 
    the “Soft” DIG will scroll through the digit positions.  When the correct value is entered, 
    pressing the ENT button will return you to the menu system. 
     
    When all digits have been set, press the MEM key to accept the value and return to 
    Program Function mode.  Upon the next reading, LO will appear on the display if the 
    captured value is less than the low limit  
    						
    							 
     
    AHCTS-K Series User’s Guide 
     DESCRIPTION OF FUNCTIONS 12 
    HIGH LIMIT 
    Use the high limit setting to visually flag the operator when a reading falls over a desired 
    maximum value. High limits are set in the identical way as low limits. Please refer to the 
    Low Limit section for details. 
     
    NOTE: The green LED on the front of the display will flash when a peak is captured that 
    falls within the limit setting.  
     
     
     
    Reaction Points 
     
    IT IS THE RESPONSIBILITY OF THE USER TO UNDERSTAND 
    PROPER REACTION GEOMETRY.  INJURY TO THE OPERATOR 
    AND/OR DAMAGE TO THE TOOL AND/OR TEST STAND WILL 
    RESULT IF PROPER REACTION IS NOT PROVIDED.  
    						
    							 
     
    AHCTS-K Series User’s Guide 
     AIMCO LIMITED WARRANTY 13 
     
    ADDITIONAL PRODUCT OPTIONS: 
     
       
     
     
     
     
     
     
     
     
     
     
     
     
    Auditor ATDA          Auditor ATDA-DC 
     
     
     
     
    Auditor ATDA-8000 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    At left is an image of the possible configurations 
    of AHCTS and AHCTS-K test stands.  Image 
    illustrates various sizes, various reaction devices 
    and illustration of rotary versus hydraulic test 
    stands.  Hydraulic test stands do not have 
    bushing support collar or rundown fixtures whilst 
    the rotary test stands do. 
    Impact Test Large Impact Test Stand  
    						
    							 
     
    AHCTS-K Series User’s Guide 
     AIMCO LIMITED WARRANTY 14 
     NEW TOOL AND ACCESSORY WARRANTY 
     
    Any new tool or accessory branded with the AIMCO, Uryu, AcraDyne or Eagle Industries name, and  purchased from 
    AIMCO, or through one of its authorized distributors or agents, is warranted to the original buyer against defects in 
    materials and workmanship for a period of one (1) year* from date of delivery. Under the terms of this warranty, 
    AIMCO will repair or replace any product or accessory warranted hereunder and returned freight prepaid proving to 
    AIMCO’s satisfaction to be defective as a result of workmanship or materials. In order to qualify for this warranty, 
    written notice to AIMCO must be given immediately upon discovery of such defect, at which time AIMCO will issue an 
    authorization to return the tool. The defective item must be promptly returned to an authorized AIMCO service center 
    with all freight charges prepaid. 
     
    REPAIRED TOOL WARRANTY 
     
    Once a tool is beyond the new product warranty period as detailed above, AIMCO repairs are subject to the following 
    warranty periods: pneumatic tools: 90 days*; electric tools and Acra-Feed: 90 days; battery tools: 30 days*; DC 
    Electric tools: 90 days* 
     
    EXCLUSION FROM WARRANTY 
     
    This warranty is valid only on products purchased from AIMCO, or thru its authorized distributors or agents. AIMCO 
    shall have no obligation pursuant to the AIMCO Warranty with respect to any tools or accessories which in AIMCO’s 
    sole judgment have been altered, damaged, misused, abused, badly worn, lost or improperly maintained. This 
    Warranty is null and void if the customer, or any other person other than an authorized representative of AIMCO, has 
    made any attempt to service or modify the tool or accessory prior to its return to AIMCO under this Warranty. 
     
    The warranty provision with respect to each such product may be amended by AIMCO from time to time in its sole 
    discretion. The liability of AIMCO hereunder shall be limited to replacing or repairing, at its option, any products which 
    are returned freight prepaid to AIMCO and which AIMCO determines to be defective as described above or, at 
    AIMCO’s option, refunding the purchase price of such products. 
     
    AIMCO reserves the right to make periodic changes in construction or tool design at any time. AIMCO specifically 
    reserves the right to make these changes without incurring any obligation or incorporating such changes or updates 
    in tools or parts previously distributed. 
     
    THE AIMCO WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, AND AIMCO 
    EXPRESSLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
    PURPOSE. THIS WARRANTY SETS FORTH THE SOLE AND EXCLUSIVE REMEDY IN CONTRACT, TORT, 
    STRICT LIABILITY, OR OTHERWISE. 
     
    THIS WARRANTY IS THE ONLY WARRANTY MADE BY AIMCO WITH RESPECT TO THE GOODS DELIVERED 
    HEREUNDER, AND MAY BE MODIFIED OR AMENDED ONLY BY A WRITTEN INSTRUMENT SIGNED BY A 
    DULY AUTHORIZED OFFICER OF AIMCO. 
     
    LIMITATION OF LIABILITY 
     
    AIMCO’S LIABILITY PURSUANT TO WARRANTY OF THE PRODUCTS COVERED HEREUNDER IS LIMITED TO 
    REFUND OF THE PURCHASE PRICE. IN NO EVENT SHALL AIMCO BE LIABLE FOR COSTS OF 
    PROCUREMENT OF SUBSTITUTE GOODS BY THE BUYER. IN NO EVENT SHALL AIMCO BE LIABLE FOR ANY 
    SPECIAL, CONSEQUENTIAL, INCIDENTAL OR OTHER DAMAGES (INCLUDING WITHOUT LIMITATION, LOSS 
    OF PROFIT) WHETHER OR NOT AIMCO HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSS, 
    HOWEVER CAUSED, WHETHER FOR BREACH OR REPUDIATION OF CONTRACT, BREACH OF WARRANTY, 
    NEGLIGENCE OR OTHERWISE. THIS EXCLUSION ALSO INCLUDES ANY LIABILITY WHICH MAY ARISE OUT 
    OF THIRD PARTY CLAIMS AGAINST BUYER. THE ESSENTIAL PURPOSE OF THIS PROVISION IS TO LIMIT 
    THE POTENTIAL LIABILITY OF AIMCO ARISING OUT OF THIS AGREEMENT AND/OR SALE. 
     
    Note:  The AIMCO Warranty confers specific legal rights, however some states or jurisdictions may not allow certain 
    exclusions or limitations within this warranty. 
     
    * All warranty periods addressed herein are determined using a standard shift, eight-hour work day. 
    						
    							AIMCO CORPORATE HEADQUARTERS 10000 SE Pine Street 
    Portland, Oregon  97216  
    Phone: (503) 254– 6600 
    Toll Free: 1 -800- 852-1368  
    AIMC
    
    O CHINA  
    Room 607, No. 3998 Hongxin Rd Dibao Plaza  
    Minhang District, Shanghai   
    China  
    Phone: 0086 -21- 34319246  
    Fax: 0086- 21-34319245
      LIT-MA
    N980      Rev. 03/2016  
    Printed in USA  ©2016 AIMCO AIMCO C
    ORPORATION D E
     MEXICO S A DE CV 
    Ave. C ristobal C olon 14529 
    Chihuahua, C hihuahua.  31125 
    Mexico 
    P
    hone: ( 01-614) 380- 1010 
    Fax: (01 -614) 380- 1019 
    AIMCO S PAIN 
    Avenida R ío Gallo, 4 31 
    19174 Galápagos - Guadalajara 
    Spain 
    P
    hone: + 34 673 34 99 25  
    						
    All Aimco Brakes manuals Comments (0)