Home
>
AEM
>
Sensors Connectors & Accessories
>
AEM Stainless Steel Pressure Sensor 302130XXX User Manual
AEM Stainless Steel Pressure Sensor 302130XXX User Manual
Have a look at the manual AEM Stainless Steel Pressure Sensor 302130XXX User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 223 AEM manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
AEM Performance Electronics 2205 126 th Street Unit A, Hawthorne, CA. 90250 Phone: (310) 484-2322 Fax: (310) 484-0152 http://www.aemelectronics.com Instruction Part Number: 10-2130 Rev B © 2011 AEM Performance Electronics The model 30-2130-XXX family of pressure transducers is specifically designed for pressure measurements in automotive systems. The mechanical connection is 1/8 Male NPT. Each sensor comes with a mating connector plug and pin kit. Instruction Manual P/N 30-2130-XXX Pressure Sensors KIT CONTENTS Part Number Sensor Connector Kit -4 Adapter 3/16 Hose Barb 30-2130-15 15 PSIa (1 Bar) Included Included Included 30-2130-30 30 PSIa (2 Bar) Included Included Included 30-2130-50 50 PSIa (3.5 Bar) Included Included Included 30-2130-75 75 PSIa (5 Bar) Included Included Included 30-2130-100 100 PSIg Included Included NA 30-2130-150 150 PSIg Included Included NA 30-2130-500 500 PSIg Included Included NA 30-2130-1000 1000 PSIg Included Included NA 30-2130-2000 2000 PSIg Included Included NA Specifications: Accuracy: +/- 1% FS Temp Error: +/- 1% FS Operating Temp: -40 to 105C Burst Pressure: 3 X FS Supply Voltage: 5V +/- 0.5V Supply Current: < 6 mA Response Time: < 1 mS Vibration: 20G Sinusoidal Weight: < 85 Grams Body Material: 304L Wetted Material: 316L Mechanical Connection: 1/8”NPT Male Electrical Connection: Packard 3-Pin Electrical Termination: Signal Ground: Tap to Sensor/Signal Ground on EMS or AQ1 Sensor Power: Tap to Sensor Power +5V on EMS or AQ1 Signal: Connect to MAP/Input Channel on EMS or Input 1-8 on AQ1
IMPORTANT! The terminals are “Pull to Seat” meaning you must feed the wire through the connector housing BEFORE you crimp on the terminals. The wire is then pulled back into the housing and the terminal locks in place. The terminal cannot be inserted or removed from the rear (wire side entry) of the housing. See Figure 1. Below VOLTAGE OUTPUT Voltage 30-2130-15 30-2130-30 30-2130-50 30-2130-75 30-2130-100 30-2130-150 30-2130-500 30-2130-1000 30-2130-2000 Range -14.7-0.3 PSIa -14.7-15.3 PSIa -14.7-35.3 PSIa -14.7-60.3 PSIa 0-100 PSIg 0-150 PSIg 0-500 PSIg 0-1,000 PSIg 0-2,000 PSIg 0.5 -14.7 -14.7 -14.7 -14.7 0 0 0 0 0 0.75 -13.763 -12.825 -11.575 -10.013 6.25 9.375 31.25 62.5 125 1 -12.825 -10.95 -8.45 -5.325 12.5 18.75 62.5 125 250 1.25 -11.888 -9.075 -5.325 -0.637 18.75 28.125 93.75 187.5 375 1.5 -10.95 -7.2 -2.2 4.05 25 37.5 125 250 500 1.75 -10.013 -5.325 0.925 8.738 31.25 46.875 156.25 312.5 625 2 -9.075 -3.45 4.05 13.425 37.5 56.25 187.5 375 750 2.25 -8.138 -1.575 7.175 18.113 43.75 65.625 218.75 437.5 875 2.5 -7.2 0.3 10.3 22.8 50 75 250 500 1000 2.75 -6.263 2.175 13.425 27.488 56.25 84.375 281.25 562.5 1125 3 -5.325 4.05 16.55 32.175 62.5 93.75 312.5 625 1250 3.25 -4.388 5.925 19.675 36.863 68.75 103.125 343.75 687.5 1375 3.5 -3.45 7.8 22.8 41.55 75 112.5 375 750 1500 3.75 -2.513 9.675 25.925 46.238 81.25 121.875 406.25 812.5 1625 4 -1.575 11.55 29.05 50.925 87.5 131.25 437.5 875 1750 4.25 -0.637 13.425 32.175 55.613 93.75 140.625 468.75 937.5 1875 4.5 0.3 15.3 35.3 60.3 100 150 500 1000 2000 12 MONTH LIMITED WARRANTY Advanced Engine Management Inc. warrants to the consumer that all AEM High Performance products will be free from defects in material and workmanship for a period of twelve (12) months from date of the original purchase. Products that fail within this 12-month warranty period will be repaired or replaced at AEM’s option, when determined by AEM that the product failed due to defects in material or workmanship. This warranty is limited to the repair or replacement of the AEM part. In no event shall this warranty exceed the original purchase price of the AEM part nor shall AEM be responsible for special, incidental or consequential damages or cost incurred due to the failure of this product. Warranty claims to AEM must be transportation prepaid and accompanied with dated proof of purchase. This warranty applies only to the original purchaser of product and is non- transferable. All implied warranties shall be limited in duration to the said 12 month warranty period. Improper use or installation, accident, abuse, unauthorized repairs or alterations voids this warranty. AEM disclaims any liability for consequential damages due to breach of any written or implied warranty on all products manufactured by AEM. Warranty returns will only be accepted by AEM when accompanied by a valid Return Goods Authorization (RGA) number. Product must be received by AEM within 30 days of the date the RGA is issued. Please note that before AEM can issue an RGA for any product, it is first necessary for the installer or end user to contact the AEM Performance Electronics tech line at 1-800-423-0046 to discuss the problem. Most issues can be resolved over the phone. Under no circumstances should a system be returned or a RGA requested before the above process transpires. Figure 1. Connector Assembly Showing Pull to Seat Terminal