Pin 1991-1995 Nissan 180SX SR20DET, 1991-1993 Nissan Silvia S13 SR20DET AEM EMS 30-6601 I/O Notes 31 Crankshaft Position Sensor Signal Crank Signal Input Dedicated, must use AEM replacement trigger disc Connects to pin 40 32 Vehicle Speed T3 Input PnP for Vehicle Speed Sensor 33 --- ADCR11 Input Available, 0-5 Volt Input 34 Start Signal +12V Switched Input Dedicated 35 Neutral Position Switch MAP Input Available, Manifold Pressure sensor input 36 Ignition Switch Main Relay (input) Input Dedicated, +12V activates Main Relay circuit 37 Throttle Position Sensor Power +5V Sensor Output Dedicated 38 Power Supply for ECM +12V Switched Input Dedicated, gets +12V power when ECCS Relay is on 39 ECCS Ground Power Ground Input Dedicated 40 Crankshaft Position Signal Crank Signal Input Dedicated, must use AEM replacement trigger disc Connects to pin 31 41 Air Conditioner Switch Switch 6 Input PnP for A/C Switch 42 A/T Signal No. 1 CAN1L Input Dedicated, CAN low side 43 Power Steering Oil Pressure Switch Switch 2 Input Available, Switched Input 44 A/T Signal No. 2 EGT 3 Input Available, jumper set for 0-5V Input 45 A/C FICD Low Side 2 Output Available, Switched Ground, 1.5A Max 46 Back-up Power Supply Permanent +12V Input Dedicated, used to store internal log data 47 Power Supply for ECM +12V Switched Input Dedicated, gets +12V power when ECCS Relay is on 48 ECCS Ground Power Ground Input Dedicated 101 Injector 1 Injector 1 Output PnP for Injector 1 (Peak & Hold 4A/1A driver) 102 Pulse Secondary Air Injection So lenoid Valve Low Side 4 Output Available, Switched Ground, 1.5A max 103 Injector 3 Injector 3 Output PnP for Injector 3 (Peak & Hold 4A/1A driver) 104 Fuel Pump Relay Low Side 11 Output PnP for Fuel Pump relay control signal 105 Fuel Pressure Control Module Injector 6 Output Available, Switched Ground, 1.5A max 106 Air Conditioner Relay Low Side 9 Output PnP for A/C Compressor 107 ECCS Ground Power Ground Input Dedicated 108 ECCS Ground Power Ground Input Dedicated 109 Reverse Electrical Flow Return Circuit Permanent +12V Input Dedicated 110 Injector 2 Injector 2 Output PnP for Injector 2 (Peak & Hold 4A/1A driver) 111 Turbo Boost Pressure Control Solenoid PW 2 Output Available, Pulse Width Out 112 Injector 4 Injector 4 Output PnP for Injector 4 (Peak & Hold 4A/1A driver) 113 Idle Auxiliary Air Control Valve PW 1 Output PnP for Idle Air Control 114 --- Injector 8 Output Available, Switched Ground, 1.5A max 115 --- EGT 4 Input Available, jumper set for 0-5V Input 116 ECCS Ground Power Ground Input Dedicated Wire View of AEM EMS 30-1601 (Series 1) vs 30-6601 (S eries 2) EMS differences: Page 11 of 13
The EMS functions assigned to certain pins have been changed and no longer match the 30-1601 EMS. Unless otherwise not ed, the following pins and functions will need to be manually reconfigured after using AEMTuner to convert a V1.19 (30-1601, Series 1 EMS) calibration for use with the 30-6601 Series 2 hardware. Pin Vehicle harness destination 30-1601 function 30-6601 functionNotes 12 A/T Signal No. 3 Low Side 5 CAN1H LS5 not available 15 Data Link Connector Injector 8 EGT 2 Injector 8 available on pin 114 42 A/T Signal No. 1 Switch 1 CAN1L Switch 1 not available 114 --- EGT 2 Injector 8 EGT 2 available on pin 15 Page 12 of 13
AEM Electronics Warranty Advanced Engine Management Inc. warrants to the consumer that all AEM Electronics products will be free from defects in material and workmanship for a period of twelve months from date of the original purchase. Products that fail within this 12-month warranty period will be repaired or repl aced when determined by AEM that the product failed due to defects in material or workmanship. This warr anty is limited to the repair or replacement of the AEM part. In no event shall this warranty exceed the original purchase price of the AEM part nor shall AEM be responsible for s pecial, incidental or consequential damages or cost incurred due to the failure of this product. Warranty claims to AEM must be transportation prepaid and accompanied with dat ed proof of purchase. This warranty applies only to the original purchaser of product and is non-transferable. All implied warranties shall be limited in duration to t he said 12-month warranty period. Improper use or installation, accident, abuse, unauthorized r epairs or alterations voids this warranty. AEM disclaims any liability for consequential damages due to breach of any written or implied warranty on all produc ts manufactured by AEM. Warranty returns will only be accepted by AEM when accompanied by a valid Return Merchandise Authoriza\ tion (RMA) number. Product must be received by AEM withi n 30 days of the date the RMA is issued. Please note that before AEM can issue an RMA for any electronic product, it is first necessary for the installer or end user to contact the tech line at 1-800-423-0046 to discuss the problem. Most issues c an be resolved over the phone. Under no circumstances should a system be returned or a RMA requested before the above process transpires. AEM will not be responsible for electronic products that are installed incorrectly, installed in a non approved application, mi sused, or tampered with. Any AEM electronics product can be returned for repair if it is out of the warranty period. There is a minimum charge of $75.00 for in spection and diagnosis of AEM electronic parts. Parts used in the repair of AEM el ectronic components will be extra. AEM will provide an estimate of repairs and receive wri tten or electronic authorization before repairs are made to the product. Page 13 of 13