    Have a look at the manual AEM KType Closed Tip Thermocouple 10 Wiring Extension Kit 302066 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 223 AEM manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							  
     
     
    ADVANCED ENGINE MANAGEMENT INC. 
    2205 126
    th Street Unit A    Hawthorne, CA. 90250 
    Phone: (310) 484-2322 Fax: (310) 484-0152 
    Http://www.aempower.com 
    Instruction Part Number: 10-2066 
    © 2009 Advanced Engine Management, Inc. 
     
     
      
    K-Type Thermocouple Extension Harness 
     
    The 30-2066 K-Type Thermocouple Extension Harness kit contains a 10’ thermocouple 
    grade extension harness, along with mounting hardware to mate with the AEM 30-2065 
    K-Type Thermocouple.  The sensor end of the harness contains two ring terminals that 
    connect to the 30-2065 K-Type thermocouple, see figure 1 below for details on 
    connecting to the K-Type thermocouple.  The other end of the harness contains a 3-
    position single row connector that mates with various AEM EGT devices.  For use with a 
    different style of connector, the harness can be cut and reterminated.  NOTE: Pay 
    special attention to polarity and wire color when reterminating.  YELLOW IS POSITIVE, 
    RED IS NEGATIVE. 
     
    Connecting the Extension Harness and Thermocouple 
     
    Slide the supplied heat shrink onto the sensor cable.  Connect the RED wire from the 
    thermocouple to the RED wire on the harness and the YELLOW wire from the 
    thermocouple to the YELLOW wire on the harness using the supplied 4-40 screws and 
    hex nuts.  Make sure the connections are not touching.  Center the heat shrink over the 
    connections and apply mild heat to the heat shrink until it shrinks over the connections. 
     
     
     
     
     
     
    Kit Contents: 
    1 x 10’ Extension Harness 
    2 x 4-40 Hex Nut 
    2 x 4-40 Screw 
    1 x Heat Shrink, 6” 
     
     
     
     
     
    HEAT SHRINK 
    Figure 1. K-Type Thermocouple Connection  
    						
    							Part Number: 30-2066 
    Wire Type: K-type Thermocouple 
    Harness Length: 10’ 
    Temperature Rating, Insulation: 105C 
    Sensor Termination: Ring Terminal 
    Polarity: + Yellow 
      -  Red 
     
    AEM Electronics Warranty 
      
    Advanced Engine Management Inc. warrants to the consumer that all AEM Electronics 
    products will be free from defects in material and workmanship for a period of twelve 
    months from date of the original purchase. Products that fail within this 12-month 
    warranty period will be repaired or replaced when determined by AEM that the product 
    failed due to defects in material or workmanship. This warranty is limited to the repair or 
    replacement of the AEM part. In no event shall this warranty exceed the original 
    purchase price of the AEM part nor shall AEM be responsible for special, incidental or 
    consequential damages or cost incurred due to the failure of this product. Warranty 
    claims to AEM must be transportation prepaid and accompanied with dated proof of 
    purchase. This warranty applies only to the original purchaser of product and is non-
    transferable. All implied warranties shall be limited in duration to the said 12-month 
    warranty period. Improper use or installation, accident, abuse, unauthorized repairs or 
    alterations voids this warranty. AEM disclaims any liability for consequential damages 
    due to breach of any written or implied warranty on all products manufactured by AEM. 
    Warranty returns will only be accepted by AEM when accompanied by a valid Return 
    Merchandise Authorization (RMA) number.  Product must be received by AEM within 30 
    days of the date the RMA is issued. 
      
    Please note that before AEM can issue an RMA for any electronic product, it is first 
    necessary for the installer or end user to contact the tech line at 1-800-423-0046 to 
    discuss the problem.  Most issues can be resolved over the phone.  Under no 
    circumstances should a system be returned or a RMA requested before the above 
    process transpires. 
      
    AEM will not be responsible for electronic products that are installed incorrectly, 
    installed in a non approved application, misused, or tampered with.  
      
    Any AEM electronics product can be returned for repair if it is out of the warranty period. 
    There is a minimum charge of $50.00 for inspection and diagnosis of AEM electronic 
    parts. Parts used in the repair of AEM electronic components will be extra. AEM will 
    provide an estimate of repairs and receive written or electronic authorization before 
    repairs are made to the product.  
     
      
    						