CAUTION! Make sure that the gas supply pressure of the appliance obeys the recommended values.Rigid connection: Carry out connection by using metal rigid pipes (copper with mechanical end). 8.5 Injectors replacement 1.Remove the pan supports. 2. Remove the caps and crowns of the burner. 3. With a socket spanner 7 remove the injectors and replace them with the ones which are necessary for the type of gas you use (see table in "Technical Information" chapter). 4. Assemble the parts, follow the same procedure backwards. 5. Replace the rating plate (it is near the gas supply pipe) with the one for the new type of gas supply. You can find this plate in the package supplied with the appliance. If the supply gas pressure is changeable or different from the necessary pressure, you must fit an applicable pressure adjuster on the gas supply pipe.8.6 Adjustment of minimum level To adjust the minimum level of the burners: 1. Light the burner. 2. Turn the knob on the minimum position. 3. Remove the knob. 4. With a thin screwdriver, adjust the bypass screw position (A for external crown and B for internal crown). 5. If you change: • from natural gas G20 20 mbar to liquid gas, fully tighten the bypass screw in. • from liquid gas to natural gas G20 20 mbar, undo the bypass screw approximately 1/4 of a turn for internal crown (B) and approximately 1/3 of a turn for external crown (A). WARNING! Make sure the flame does not go out when you quickly turn the knob from the maximum position to the minimum position.8.7 Electrical connection • Do not pull the mains cable to disconnect the appliance. Always pull the mains plug (if applicable). • The appliance must not be connected with an extension cable, an adapter or a multiple socket. There is a risk of fire. • Do not let the power cable to heat up to a temperature of more than 90° C.The cable should be guided by means ENGLISH21 A B
![](/img/blank.gif)
of clamps fixed to the side of the cabinet, in order to avoid any contact with the equipment beneath thecooktop.Electrical Requirements Permanent electrical installation must agree with the latest I.E.E. Regulations and local Electricity Board regulations. For your own safety the installation must be done by a qualified electrician (e.g. your local Electricity Board, or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting [NICEIC]). The manufacturer refuses to be held responsible, if these safety measures are not abided by.Supply connections This hob has to be connected to 230 — 240 V ( 50 Hz) electricity supply. The hob has a terminal block which is marked as follows: • L or 1 - live terminal • N or 4 - neutral terminal • or E or 5 - earth terminal Before carrying out the connection, make sure: 1. The limiter valve and the electrical system can take the appliance load (see the rating plate) 2. The supply system is equipped with an efficient earth connection in compliance with the current standards and regulations 3. The outlet or omnipolar switch used for connection is easily accessible with the appliance installed. You must purchase and install the power cable. Use only a connection cable of type H05V2V2-F T90 or its equivalent. Make sure that the cable section is applicable to the voltage load and the working temperature. The wires in the cord are coloured as follows: Green and yellow- EarthBlue- NeutralBrown- LiveWARNING! A cut off plug inserted into a 13 amp socket is a serious shock hazard. Ensure that the cut off plug is disposed of safely.8.8 Replacement of the connection cableThe replacement of electric cable must be carried out exclusively by the service force centre or by personnel with similar competencies, in accordance with the current regulations.Make sure that the cable section is applicable to the voltage load and the working temperature. The yellow/green earth wire (B) must be approximately 2 cm longer than the live and neutral wire (A). 1. Connect the green and yellow (earth) wire to the terminal which is marked with the number 5, or the letter 'E', or the earth symbol , or coloured green and yellow. 2. Connect the blue (neutral) wire to the terminal which is marked with the number 4, or the letter 'N', or coloured blue. 3. Connect the brown (live) wire to the terminal which is marked with the number 1, or the letter 'L'. It must always be connected to the network www.aeg.com22 A B
![](/img/blank.gif)
phase. There must be no cut or stray strands of wire present. The cord clamp must be correctly attached to the outer sheath.8.9 Attaching the seal 1.Clean the worktop around the cut out area. 2. Attach the supplied seal stripe to the lower edge of the hob along the outer edge of the glass ceramic. Do not extend it. Make sure that the ends of the seal stripe are located in the middle of one side of the hob. 3. Add some mm when you cut the seal stripe to the length. 4. Push the two ends of seal stripe together.8.10 AssemblyENGLISH23min. 450mm min.650mm min. 2mm < 20 mm min. 2 mm A B A 12 mm28 mm 38 mm B 57 mm41 mm31 mm min 30 mmmin. 500 mm > 20 mm min. 2 mm A B A 12 mm28 mm 38 mm B 57 mm41 mm31 mm min. 500 mm
![](/img/blank.gif)
CAUTION! Install the appliance only on a worktop with a flat surface.8.11 Possibilities for insertionKitchen unit with door The panel installed below the hob must be easy to remove and let an easy access in case a technical assistance intervention is necessary. A) Removable panel B) Space for connections Kitchen unit with oven The electrical connection of the hob and the oven must be installed separately for www.aeg.com24R 5 mm min. 55 mm 490 mm830 mm 600 mm min. 38 mm min. 2 mm min. 12 mm min. 2 mm min. 40 mm (+2 mm) min. 30 mmmin. 60 mm b a
![](/img/blank.gif)
safety reasons and to let easy remove oven from the unit.If you install the hob asymmetrically rightward the minimum distance between left edge of the hob and left support must be 72 mm.9. TECHNICAL INFORMATION9.1 Hob dimensionsWidth880 mmDepth520 mm9.2 Cooking zones specificationCooking zoneNominal power (maximum heat setting) [W]Power function [W]Power function maximum dura- tion [min]Cookware diam- eter [mm]Left front220036005180 - 210Left rear140025004125 - 145Right front140025004125 - 145Right rear1800280010145 - 180The power of the cooking zones can be different in some small range from the data in the table. It changes with the material and dimensions of the cookware.For optimal cooking results use cookware not larger than the diameter in the table.9.3 Bypass diametersBURNERØ BYPASS 1/100 mmDual (internal crown)29Dual (external crown)579.4 Other technical data TOTAL POWER: Gas original:G20 (2H) 20 mbar = 5 kWGas replacement:G30 (3+) 28-30 mbar = 334 g/h G31 (3+) 37 mbar = 329 g/hElectric zones:6,8 kWENGLISH25 min. 72 mm
![](/img/blank.gif)
Electric supply:230 V ~ 50 HzAppliance category:II2H3+ Gas connection:R 1/2" Appliance class:3 9.5 Gas burners for NATURAL GAS G20 20 mbarBURNERNORMAL POWER kWMINIMUM POWER kWINJECTOR MARK 1/100 mmDual5,01,4270 / 115Dual (internal crown)0,80,33709.6 Gas burners for LPG G30/G31 28-30/37 mbarBURNERNORMAL POWER kWMINIMUM POWER kWINJECTOR MARK 1/100 mmNOMINAL GAS FLOW g/hG30 28-30 mbarG31 37 mbarDual4,61,4246 / 72334328Dual (inter- nal crown)0,80,3346585710. ENVIRONMENTAL CONCERNSRecycle the materials with the symbol . Put the packaging in applicable containers to recycle it. Help protect the environment and human health and to recycle waste of electrical and electronic appliances. Do not dispose appliances marked with the symbol with the household waste. Return the product to your local recycling facility or contact your municipal office. * www.aeg.com26