Page 11
7.1 What to do if...ProblemPossible causeRemedyThere is no spark when you try to activate the spark gen- erator.The hob is not connected to an electrical supply or it is connected incorrectly.Check if the hob is correctly connected to the electrical supply. The fuse is blown.Make sure that the fuse is the cause of the malfunction. If the fuse is blown again and again, contact a quali- fied electrician. Burner cap and crown are placed incorrectly.Place the burner cap and crown correctly.The flame...
Page 12
7.3 Labels supplied with the accessories bag Stick the adhesive labels as indicated below:A. Stick it on Guarantee Card and send this part (if applicable). B. Stick it on Guarantee Card and keep this part (if applicable).C. Stick it on instruction booklet.8. INSTALLATIONWARNING! Refer to Safety chapters.8.1 Before the installation Before you install the hob, write down the information bellow from the rating plate. The rating plate is on the bottom of the hob. Model...
Page 13
However, if the room has a door whichopens directly to the outside no air vent is required even if the volume is between 5 m³ and 11 m³. If there are other fuel burning appliances in the same room, B.S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. For appliances installed in the Republic of Ireland please refer to the NSAI- Domestic Gas Installation I.S. 813 Current Editions Table Four.Location The hob may be located in a kitchen, a kitchen/diner or...
Page 14
8.4 Injectors replacement 1. Remove the pan supports. 2. Remove the caps and crowns of the burner. 3. With a socket spanner 7 remove the injectors and replace them with the ones which are necessary for the type of gas you use (see table in "Technical Information" chapter). 4. Assemble the parts, follow the same procedure backwards. 5. Replace the rating plate (it is near the gas supply pipe) with the one for the new type of gas supply. You can find this plate in the package supplied with the...
Page 15
2.The supply system is equipped with an efficient earth connection in compliance with the current standards and regulations 3. The outlet or omnipolar switch used for connection is easily accessible with the appliance installed. The appliance is supplied with a 3 core flexible power cable with a 3 amp plug. If it is necessary to change the fuse, use a 3 amp ASTA-approved (BS 1362) fuse. A. Green and Yellow B. 3 amp fuse C. Brown D. Cord clamp E. Blue The wires in the cord are coloured as follows: Green...
Page 16
8.8 Assembly 1. 2. 3. 4. If a furniture unit is installed at a distance of 400 mm above the hob, there must be a minimum safety distance of 50 mm to the left or right from the edge of the hob. 5. 6. A) supplied bracket 7. CAUTION! Install the appliance only on a worktop with flat surface.8.9 Possibilities for insertion The panel installed below the hob must be easy to remove and let an easy accessin case a technical assistance intervention is necessary. www.aeg.com16 min. 55 mm min. 650 mm 560 mm min....
Page 17
Kitchen unit with door or drawerA.Removable panel B. Space for connectionsKitchen unit with oven The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit. 9. TECHNICAL DATA9.1 Hob dimensionsWidth576 mmDepth516 mm9.2 Bypass diametersBURNERØ BYPASS 1/100 mmTriple Crown57Semi-rapid42Auxiliary329.3 Other technical data TOTAL POWER: Gas original:G20 (2H) 20 mbar = 8,6 kWGas replacement:G30 (3+) 28-30 mbar = 625 g/h G31 (3+)...
Page 18
Gas connection:R 1/2" Appliance class:3 9.4 Gas burners for NATURAL GAS G20 20 mbarBURNERNORMAL POWER kWMINIMUM POWER kWINJECTOR MARK 1/100 mmTriple Crown3,81,4146Semi-rapid1,90,7596xAuxiliary1,00,45709.5 Gas burners for LPG G30/G31 28-30/37 mbarBURNERNORMAL POWER kWMINIMUM POWER kWINJECTOR MARK 1/100 mmNOMINAL GAS FLOW g/hG30 28-30 mbarG31 37 mbarTriple Crown3,81,498276271Semi-rapid1,90,7571138136Auxiliary1,00,4550737110. ENERGY EFFICIENCY10.1 Product information according to EU 66/2014Model...
Page 19
• Center the pot on the burner. • When you heat up water, use only the amount you need. • If it is possible, always put the lids on the cookware. • When the liquid starts to boil, turn down the flame to barely simmer the liquid. • If it is possible, use a pressure cooker. Refer to its user manual.11. ENVIRONMENTAL CONCERNSRecycle the materials with the symbol . Put the packaging in applicable containers to recycle it. Help protect the environment and human health and to recycle waste of electrical and...